Danfoss

131L9862 Danfoss VLT HVAC Basic Drive FC-101 0.75kW VFD

SKU 131L9862

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 131L9862

  • Country of origin:United States

  • Product Type: FC-101PK75T4E20H4

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 131L9862 (131L9862) is a compact and efficient variable frequency drive from the Danfoss VLT® HVAC Basic Drive FC-101 series. Specifically engineered for 0.75 kW (1.0 HP) motor control, this drive is optimized for basic HVAC applications such as small centrifugal pumps and fans. By modulating motor speed to match actual demand, the 131L9862 reduces energy consumption and mechanical wear on building systems. Its IP20 enclosure is designed for space-saving cabinet installation, while the integrated H4 RFI filter ensures compliance with industrial electromagnetic standards (Class A1/C2). This drive offers a streamlined, reliable solution for modern building automation and climate control infrastructures.

Suffix Breakdown

The model code FC-101PK75T4E20H4 specifies the precise configuration for this 0.75kW unit:

  • FC-101: Part of the VLT® HVAC Basic Drive series.

  • PK75: Indicates a power rating of 0.75 kW (1.0 HP).

  • T4: Three-phase input for 380 - 480 VAC mains voltage.

  • E20: IP20 / Chassis enclosure rating, designed for installation in control panels.

  • H4: Integrated RFI Filter Class A1 (Category C2) for effective noise suppression.

Technical Specifications

Feature Specification
Model 131L9862
Brand Danfoss
Power Rating 0.75 kW / 1.0 HP
Mains Voltage 380 - 480 VAC (3-Phase)
Enclosure Rating IP20 / Chassis
RFI Filter Class A1 (C2) Integrated
Output Frequency 0 - 200 Hz (VVC+) / 0 - 400 Hz (U/f)
Efficiency >96%
Net Weight 2.3 kg
Shipping Weight 4.0 kg

Technical FAQs

What are the standard communication protocols for the FC-101?

The 131L9862 comes equipped with built-in protocols specifically for the HVAC industry, including BACnet MS/TP, Modbus RTU, and Danfoss FC Protocol. This allows for direct integration into a Building Management System (BMS) for remote monitoring and control.

Does the IP20 rating allow for mounting outside of a cabinet?

No. The IP20 (E20) rating indicates the drive is an "open type" component. It must be installed within a protective enclosure or control panel to prevent accidental contact with live parts and to protect the electronics from dust and moisture.

Is an external display required for commissioning?

The FC-101 series usually requires an LCP (Local Control Panel) for local parameter adjustment. However, the drive can also be configured using a PC via the built-in RS485 port using the free Danfoss VLT® Motion Control Tool MCT 10.


Engineering & Installation Guide

  • Space Management: The 131L9862 supports side-by-side mounting, which is ideal for high-density control panels. To ensure adequate cooling, maintain a minimum of 100 mm of vertical clearance above and below the drive to allow for natural convection through the heat sink.

  • EMC Best Practices: To utilize the integrated H4 RFI filter effectively, you must use shielded (screened) motor cables. Ensure the cable shield is connected to the drive's metal decoupling plate using a 360-degree clamp to provide a low-impedance path for high-frequency noise.

  • Motor Protection: For optimal performance, perform an Automatic Motor Adaptation (AMA) during commissioning. This allows the drive to measure the motor's actual electrical characteristics, optimizing the VVC+ control algorithm for maximum torque and energy efficiency.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.