ABB

ABB 3BHE039426R0101 UF C912 A101 EOI Protection Board

SKU 3BHE039426R0101

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: 3BHE039426R0101

  • Country of origin:Switzerland,United States

  • Product Type: EOI Protection Board

  • Barcode: 85049090

  • Payment: T/T, Western Union

  • Weight: 130g

  • Dimensions: 8 cm x 9 cm x 2.3 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 3BHE039426R0101 (UF C912 A101) is a specialized Protection Board and End of Instruction (EOI) interface module engineered for ABB Medium Voltage (MV) Drives, specifically within the ACS 2000 and ACS 6000 product lines. In heavy industrial applications such as maritime propulsion, mineral grinding, and large-scale water pumping, electrical transients and synchronization errors can lead to catastrophic hardware failure. The UF C912 A101 serves as a frontline defense mechanism, monitoring critical drive parameters to execute high-speed protection sequences. By ensuring the integrity of control signals and providing high-speed isolation, this board is instrumental in maximizing MTBF (Mean Time Between Failure) and preventing costly unscheduled downtime in high-power conversion environments.

Technical Configuration

The UF C912 A101 architecture is optimized for real-time protection and feedback within the drive's control sub-rack. It handles high-speed logic for fault detection and ensures that protection triggers are communicated to the power semiconductor gate drivers with minimal latency.

  • System Integration: Primarily utilized in ACS 2000 and ACS 6000 AD (Asynchronous Drive) configurations.

  • Interchangeability: For ACS 2000 systems, the 3BHE039426R0111 (UF C912 A111) is a 1-to-1 functional replacement. Note that while the R0111 version does not support SSI encoder functions, this feature is typically unused in the ACS 2000 series.

  • Application Check: For ACS 6000 SD (Synchronous Drive) applications, engineering verification is required to ensure firmware and hardware compatibility before deployment.

Technical Specifications

Attribute Details
Model 3BHE039426R0101
ABB Type Designation UF C912 A101: EOI
Brand ABB
Function Protection Board / EOI
Country of Origin Switzerland / United States
Product Net Weight 0.13 kg
Customs Tariff Number 85049090
Operating Temperature 0 to 55 deg C
Product Type Spare_Parts
UNSPSC 39122004

FAQs

Can I use the UF C912 A111 instead of the A101 in an ACS 2000 drive?

Yes, the UF C912 A111 (3BHE039426R0111) is a direct 1-to-1 replacement for the ACS 2000. It lacks the SSI encoder function, but since ACS 2000 units do not utilize SSI encoders, there is no loss of functionality.

What information is required before purchasing this protection board?

The specific drive serial number is mandatory before ordering. This ensures that the hardware revision and factory-loaded firmware on the board are compatible with your existing MV drive configuration.

Is this board compatible with ACS 6000 SD (Synchronous Drives)?

Compatibility for the Synchronous Drive (SD) variant must be checked through official technical support channels. While it is standard for the Asynchronous Drive (AD), the SD variant may have different timing or interface requirements.


Engineering Support and Installation Safety

  • Serial Number Verification: Under no circumstances should this board be installed without verifying the drive's serial number against ABB's global database. Incorrect hardware revisions can lead to protection bypass or improper drive firing sequences.

  • Static Sensitive Handling: This module contains highly sensitive gate-logic components. Use a grounded ESD (Electrostatic Discharge) wrist strap during the entire installation process. Do not touch the gold finger edge connectors or integrated circuits directly.

  • MV Safety Protocol: Before accessing the drive internals to replace the 3BHE039426R0101, ensure the Medium Voltage supply is locked out and tagged out (LOTO). Allow at least 15 to 30 minutes for the DC link capacitors to discharge to a safe level (below 50 VDC) as per your drive's specific safety manual.

  • Firmware Synchronization: After hardware installation, verify if a firmware update or parameter synchronization is required via the DriveWindow or relevant ABB service tool to ensure the new board is recognized by the main controller.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Switzerland United States

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.