ABB 3BSE081637R1 PM866AK02 is a redundant central processing unit package designed for the AC 800M control system within the ABB Ability System 800xA platform. The unit houses a microprocessor, RAM, real-time clock, LED status indicators, INIT push button, and a CompactFlash interface. It provides CPU hardware redundancy with a maximum switchover time of 10 ms for high availability application environments. Network connectivity includes two built-in RJ45 Ethernet ports for Control Network communication using MMS and IAC protocols, alongside RS-232C serial ports for configuration and general communication. The controller interface extends to Modulebus and CEX-Bus communication lines, managing up to 32 applications and supporting up to 84 Modulebus I/O modules in a redundant processor setup.
Features
CPU redundancy support with a maximum 10 ms switchover time
Integrated MPC866 processor running at 133 MHz with 64 MB RAM
Two RJ45 Ethernet ports supporting MMS and IAC Control Network protocols
DIN rail attachment using a slide and lock mechanism
Built-in Lithium 3.6 V backup battery for memory protection
Clock synchronization across controllers using CNCP protocol
Support for CEX-bus expansion and optical Modulebus I/O clusters
2 (COM3 non-isolated with RTS-CTS; COM4 isolated service port)
CEX Bus Communication Modules
Up to 12
CEX Bus Supply Current
Max 2.4 A
Modulebus I/O Clusters (Redundant CPU)
0 electrical + 7 optical
Modulebus I/O Capacity (Redundant PM866)
Max 84 I/O modules
Applications per Controller
Up to 32
Programs per Application
Up to 64
Operating Temperature
0 to +55 degC (+32 to +131 degF)
Storage Temperature
-40 to +70 degC (-40 to +158 degF)
Relative Humidity
5 to 95 %, non-condensing
Pollution Degree
Degree 2 (IEC/EN 61131-2)
Corrosion Protection
G3 compliant (ISA 71.04)
Protection Class
IP20 (EN 60529, IEC 529)
Operating Altitude
Up to 2000 m
Dimensions (W x H x D)
119 mm x 186 mm x 135 mm
Weight
2700 g (5.95 lbs)
Installation Guidelines
DIN Rail Mounting: Mount the baseplate using the slide and lock mechanism. Ensure appropriate space on the DIN rail for the baseplate width.
Power Connections: Supply a nominal 24 V DC source within the allowed operating range of 19.2 V DC to 30 V DC.
Network and Bus Cables: Use TK850 for CEX-bus expansion and TK851 for RCU-Link connections as included in the redundancy set. Connect Control Network lines via standard 8-pole RJ45 female Ethernet ports.
Termination: Attach the provided TB807 ModuleBus terminators to the designated cluster ends.
Environmental Considerations: Maintain operating temperatures between 0 degC and +55 degC in environments rated for Pollution Degree 2 and IP20 protection.
Compliance and Certifications
Electrical Safety: EN 50178, IEC 61131-2, UL 61010-1, UL 61010-2-201
Hazardous Location: UL 60079-15, cULus Class 1, Zone 2, AEx nA IIC T4, ExnA IIC T4Gc X
EMC / Immunity & Emission: EN 61000-6-2, EN 61000-6-4
Cyber Security: ISA Secure certified
Environmental Standards: EU RoHS, UAE RoHS, CN RoHS, WEEE DIRECTIVE/2012/19/EU
Marine Certificates: DNV-GL
CE Mark: Yes
FAQ
What is the maximum CPU switchover time in a redundant configuration for this processor set?
The maximum switchover time in a redundant configuration is 10 ms.
What power supply voltage is required to operate the device?
The device requires a nominal power supply of 24 V DC, within an allowable operating range of 19.2 to 30 V DC.
How many Modulebus I/O modules are supported in a redundant setup?
A redundant processor set supports up to 84 Modulebus I/O modules.
What is the ambient operating temperature range for the unit?
The operating temperature range is 0 to +55 degC (+32 to +131 degF).
Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.
A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...
A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...
Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...
Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...
Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.
Choosing a selection results in a full page refresh.