ABB

ABB ACS2000 PBA E10 A01: 6k100 3BHB024711R0020 Phase Module

SKU 3BHB024711R0020

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: 3BHB024711R0020

  • Country of origin:United States,Poland

  • Product Type: Phase Module

  • Barcode: 85044087

  • Payment: T/T, Western Union

  • Weight: 37000g

  • Dimensions: 650 x 400 x 650 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ABB PBA E10 A01: 6k100 3BHB024711R0020 (PBAE10A01 3BHB024711R0020) is a power phase module designed for industrial drive applications. The unit incorporates a 3x47uF internal capacitor configuration and provides essential switching and power conversion capability within compatible drive assemblies.

Features

  • Mechanically identical design across direct replacement variants
  • Integrates 3x47uF capacitance configuration within the phase module architecture

Applications

  • ABB industrial variable speed drive power units
  • Active Front End (AFE) drive systems
  • Drives equipped with sine output filters

Ordering Information

Product ID Type Designation Description
3BHB024711R0020 PBA E10 A01: 6k100 PHASE MODULE 3X47UF

Technical Specifications

Parameter Value
Manufacturer ABB
Product ID 3BHB024711R0020
ABB Type Designation PBA E10 A01: 6k100
Product Name PHASE MODULE 3X47UF
Product Net Weight 37 kg
Country of Origin United States, Poland
Customs Tariff Number 85044087

Installation Guidelines

  • Ensure proper mechanical mounting inside the drive chassis as all replaced modules share identical mechanical dimensions.
  • If replacing part number 3BHB024711R0010 in a system that includes a sine output filter or an Active Front End (AFE) drive, interface cable 3BHB036579R0001 must be ordered and connected.
  • Verify software and firmware requirements prior to commissioning, as on-site programming by a certified Field Service Engineer (FSE) may be required.

FAQ

What additional hardware is required when replacing older 3BHB024711R0010 modules?

If the drive features a sine output filter or uses an Active Front End (AFE) configuration, interface cable 3BHB036579R0001 must also be ordered.

Is software or firmware configuration required during installation?

The module contains firmware or software that may require on-site programming by a certified Field Service Engineer.

Are older module variants physically compatible with this unit?

Yes, all replaced module variants listed for this product are mechanically identical.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB ACS2000 PBA E10 A01: 6k100 3BHB024711R0020 Phase Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 4
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States Poland

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.