1 of 6

ABB ACS550-01-08A8-4 ACS550 Variable Frequency Drive

ABB ACS550-01-08A8-4 ACS550 Variable Frequency Drive

Only 5 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: ACS550-01-08A8-4

  • Country of origin:Sweden

  • Product Type: Variable Frequency Drives

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 6500g

  • Dimensions: 12.50 x 36.90 x 21.20 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Engineered to deliver precise speed and torque control for three-phase induction motors, the ABB ACS550-01-08A8-4 variable frequency drive integrates seamlessly into low-voltage industrial power systems. This highly reliable motor controller supports an output power rating of 4 kW (5 HP) under normal duty conditions and operates across a standard supply voltage range of 380 to 480 V AC. As part of the established ACS550 series, this drive features an integrated swinging choke that significantly lowers harmonic distortion compared to standard line reactors, enhancing the operational lifespan of connected electrical infrastructure. The unit is housed in a robust IP21 protection enclosure, making it ideal for standard wall-mounted industrial installations requiring dependable thermal dissipation and compact spatial footprints.

Features

  • Patented Swinging Choke: Reduces line harmonics up to 25% at partial loads without the bulk of external line reactors.
  • Flexible Control Modes: Supports scalar (V/Hz) and sensorless vector control for adaptable torque profiles.
  • Integrated EMC Filter: Built-in RFI/EMC filter ensures compliance with European and domestic high-frequency interference standards.
  • Native Fieldbus Interface: Standard Modbus RTU interface on RS-485 terminals simplifies integration into distributed SCADA architectures.
  • FlashDrop Compatibility: Enables parameter uploading and drive programming in seconds without applying main power.

Applications

  • Centrifugal pumps requiring energy-efficient flow control and quadratic torque profiles.
  • Industrial supply and exhaust fans utilizing speed-regulated HVAC air distribution.
  • Material handling conveyors demanding controlled acceleration and deceleration ramps to prevent mechanical stress.
  • Mixers, agitators, and dosing systems requiring constant low-speed torque stability.

Technical Specifications Table

Parameter Specification
Manufacturer ABB
Model Number ACS550-01-08A8-4
Series ACS550 Standard Drive
Input Voltage Range 380 to 480 V AC (+10% / -15%)
Number of Phases 3-Phase Input / 3-Phase Output
Normal Duty Output Power 4 kW (5 HP)
Normal Duty Output Current 8.8 A
Heavy Duty Output Power 3 kW (4 HP)
Heavy Duty Output Current 6.9 A
Input Frequency Range 48 to 63 Hz
Enclosure Rating IP21 (UL Type 1)
Control Connections 2 Analog Inputs, 2 Analog Outputs, 6 Digital Inputs, 3 Relay Outputs
Communications Modbus RTU (Embedded)
Product Dimension (W x H x D) 12.50 x 36.90 x 21.20 cm
Net Shipping Weight 6.50 kg
Commodity Code 85044095

Connections and Interfaces

Terminal Designation Function / Assignment
U1, V1, W1 3-Phase AC Power Input Terminals
U2, V2, W2 3-Phase AC Variable Frequency Output to Motor
BRK+, BRK- Dynamic Braking Resistor External Connections
AI1 / AI2 Analog Inputs (Voltage 0...10V / Current 0/4...20mA)
AO1 / AO2 Analog Outputs (Programmable, standard 0/4...20mA)
DI1...DI6 Digital Inputs (Configurable, 12...24V DC PNP/NPN logic)
RO1, RO2, RO3 Relay Outputs (Form C, programmable, max 250V AC / 30V DC)

Alternative Models & Compatibility

The ACS550-01-08A8-4 directly replaces legacy Frame R1 ACS400 drives with minimal mechanical adaptation. When retrofitting, note that digital I/O macros may default to "ABB Standard"; ensure your existing control wire maps match the programmed macro. For network upgrades, this VFD is fully compatible with optional fieldbus modules including the RPBA-01 (Profibus-DP), RCAN-08 (CANopen), and RETA-01 (EtherNet/IP / Modbus TCP).

Application Pitfalls & Engineering Notes

For high-elevation installations exceeding 1000 meters above sea level, the output current must be derated by 1% for every additional 100 meters. Additionally, when using motor cables longer than 100 meters (328 feet), parasitic capacitance to earth can cause false "F0016" (Earth Fault) trips. In these configurations, an external du/dt filter or output reactor must be installed to protect the drive's output IGBT bridge and prevent winding degradation on older motors.

Commissioning & Wiring Tips

To configure analog input signals, ensure the onboard DIP switches (located behind the Assistant Control Panel assembly on the control board) match the desired input signal type: Switch J1 controls AI1 (Voltage/Current) and Switch J2 controls AI2 (Voltage/Current). Ensure control wiring is run in separate conduits from high-power motor and input cables to prevent high-frequency noise coupling. Always ground the motor cable shield 360 degrees at both the VFD clamp and the motor terminal box.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Before beginning any installation, maintenance, or terminal wiring, disconnect all input power sources and lock out all disconnects. Wait a minimum of 5 minutes after de-energizing the drive to allow the internal DC bus capacitors to discharge fully. Verify zero voltage across terminals U1/V1/W1 and the DC bus terminals prior to handling internal components.

1

Mount the drive vertically on a flat, non-flammable surface, ensuring at least 200 mm of clearance above and below the cooling fan assembly for unimpeded vertical airflow.

2

Connect the input power conductors to terminals U1, V1, and W1, and the protective earth (PE) grounding conductor to the drive's primary chassis ground terminal.

3

Terminate the motor cables to U2, V2, and W2 using symmetrically shielded motor cables to minimize electromagnetic radiation and bearing currents.

4

Wire control, interlock, and emergency stop circuits to the I/O terminals, separating them by at least 200 mm from the high-voltage power lines.

Loading product navigation…

What does the 'F0016' earth fault indicate on this VFD?

An F0016 fault indicates an asymmetrical earth/ground leakage current in the motor or motor cable. Check the insulation resistance of both the motor windings and the motor cabling using a megohmmeter after disconnecting the drive completely.

Can this drive run on single-phase utility power?

This model is rated for three-phase input power. Operating it on a single-phase supply is not recommended unless substantial current derating (typically 50%) is applied, and parameter 3007 (Input Phase Loss) is configured to prevent automatic tripping.

How do I switch the analog input signals between voltage and current modes?

Locate the J1 jumper block on the control board directly below the keypad mounting cradle. Change the jumper placement for AI1 or AI2 to 'I' for 0/4-20mA current loops, or 'V' for 0-10V voltage signals, and align parameter 1301/1304 accordingly.

What is the function of the built-in swinging choke?

The swinging choke matches drive inductance to the load state. It reduces input line current harmonics up to 25% under partial load conditions and improves the line voltage THD (Total Harmonic Distortion) profile compared to standard input reactors.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Recently Viewed Products

Technical knowledge

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...