ABB ACS880-04-880A-5 3ABD00039385-D LV AC Industrial Single Drive Module
SKU 3ABD00039385-D
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
ABB
Product No.:
3ABD00039385-D
Country of origin:China
Product Type:
LV AC Industrial Single Drive Module
Payment:
T/T, Western Union
Weight:
199000g
Dimensions:
1741 mm X 350 mm X 506 mm
Shipping port:
Xiamen
Warranty:
12 months
Description
The ABB ACS880-04-880A-5 (Product ID: 3ABD00039385-D) is a low-voltage AC industrial single drive module designed for cabinet-built variable speed and torque control in high-power industrial motor applications. Operating from a three-phase 380 to 500 V AC supply at 47.5 to 63 Hz, the drive delivers 630 kW (880 A) for normal use, 560 kW (857 A) for light-overload duty, and 500 kW (697 A) for heavy-duty operation, with a rated apparent power output of 762 kV-A.
Engineered within the ACS880-04 module architecture, this IP20 (NEMA Open Type) drive integrates core power conditioning directly into the chassis, including a built-in choke for harmonic filtering as standard equipment. Its control unit--which houses the onboard I/O and communication connections--can be integrated directly onto the power module or mounted separately inside the electrical cabinet to simplify field wiring and operator access.
For panel builders and system integrators working with space-constrained switchgear, the ACS880-04-880A-5 supports narrow bookshelf mounting, flat mounting, and horizontal mounting alongside flexible cabling directions. Application-specific capabilities can be added via optional hardware modules, including a brake chopper, EMC filter, communication protocol adapter, functional safety modules, and I/O extension modules.
Features
Multi-Duty Output Capacity: Delivers 630 kW / 880 A in normal use, 560 kW / 857 A in light-overload duty, and 500 kW / 697 A in heavy-duty operation on a 380 to 500 V three-phase supply.
Built-In Harmonic Filtering Choke: Includes an internal choke as standard hardware to reduce line harmonic distortion without requiring a separate external reactor for basic filtering.
Detachable or Integrated Control Unit: Allows the control unit with its I/O and communication interfaces to remain mounted on the power module or be installed externally inside the enclosure.
Flexible Cabinet Mounting Geometry: Accommodates narrow bookshelf, flat, and horizontal mounting positions with adaptable cabling directions to fit diverse cabinet layouts.
IE2 High-Efficiency Performance: Rated at efficiency level IE2, achieving 98.2% efficiency at 90% frequency under 50% to 100% load current and 713 W standby loss.
Modular Hardware Expansion: Accepts optional accessories including a brake chopper, EMC filter, communication protocol adapter, functional safety modules, and I/O extension modules.
IP20 Open-Type Chassis: Built for enclosure integration with IP20 ingress protection and an ambient operating temperature rating from -15 degC to 40 degC.
Applications
Hoisting and Material Handling Equipment: Variable speed and torque control for cranes, winches, winders, conveyors, and industrial elevators demanding up to 500 kW / 697 A heavy-duty overload capability.
Pumps, Fans, and Compressors: Flow and pressure control for centrifugal pumps, industrial ventilation fans, and compressors operating under normal (630 kW / 880 A) or light-overload (560 kW / 857 A) duty profiles.
Continuous Process and Rotating Machinery: Coordinated drive control for extruders, industrial mixers, centrifuges, and mechanical test benches.
Heavy Industrial Facilities: Cabinet-integrated motor control across oil and gas, mining, metals, chemicals, cement, power plants, material handling, pulp and paper, sawmills, marine, water and wastewater, food and beverage, and automotive installations.
Ordering Information
Item
Specification
ABB Type Designation
ACS880-04-880A-5
Global Commercial Alias
ACS880-04-880A-5
ABB Product ID
3ABD00039385-D
Invoice Description
ACS880-04-880A-5 PN:630KW, IN:880A
Model Code Breakdown
ACS880 (Series) - 04 (Single drive module construction) - 880A (Nominal current rating) - 5 (380...500 V voltage class)
Selling Unit / MOQ
1 piece (Order Multiple: 1 piece)
Order Status
Standard item (Made to Order: No; Quote Only: No)
Customs Tariff Number / HS Code
8504409999 / 850440 (Static converters)
UNSPSC Classification
39122001
Standard Included Hardware
Single drive power module, integrable or externally mountable control unit, built-in harmonic filtering choke
Module (narrow bookshelf, flat, and horizontal mounting)
Electrical
Parameter
Specification
Number of Phases
3-phase
Input Voltage ($U_{in}$)
380 ... 500 V
Input Frequency ($f$)
47.5 ... 63 Hz
Output Power, Normal Use ($P_n$)
630 kW
Output Current, Normal Use ($I_n$)
880 A
Output Power, Light-Overload Use ($P_{LD}$)
560 kW
Output Current, Light-Overload Use ($I_{LD}$)
857 A
Output Power, Heavy-Duty Use ($P_{HD}$)
500 kW
Output Current, Heavy-Duty Use ($I_{HD}$)
697 A
Apparent Power Output
762 kV-A
Efficiency and Operating Point Losses
Parameter
Specification
Efficiency Level
IE2
Standby Loss
713 W
Operating Point 0% Frequency / 25% Current
3077 W absolute loss, 0.4% relative loss, 93.0% efficiency
Operating Point 0% Frequency / 50% Current
4332 W absolute loss, 0.6% relative loss, 94.9% efficiency
Operating Point 0% Frequency / 100% Current
7668 W absolute loss, 1.0% relative loss, 95.4% efficiency
Operating Point 50% Frequency / 25% Current
3302 W absolute loss, 0.4% relative loss, 96.2% efficiency
Operating Point 50% Frequency / 50% Current
4769 W absolute loss, 0.6% relative loss, 97.2% efficiency
Operating Point 50% Frequency / 100% Current
8947 W absolute loss, 1.2% relative loss, 97.4% efficiency
Operating Point 90% Frequency / 50% Current
5540 W absolute loss, 0.7% relative loss, 98.2% efficiency
Operating Point 90% Frequency / 100% Current
11206 W absolute loss, 1.5% relative loss, 98.2% efficiency
Mechanical and Dimensions
Parameter
Specification
Degree of Protection
IP20
Enclosure Type (NEMA)
Open Type
Product Net Height
1741 mm
Product Net Width
350 mm
Product Net Depth / Length
506 mm
Product Net Weight
199 kg
Package Level 1 Height
690 mm
Package Level 1 Width
645 mm
Package Level 1 Depth / Length
2050 mm
Environmental and Classifications
Parameter
Specification
Ambient Operating Temperature Range
-15 degC to 40 degC (Minimum -15 degC, Maximum 40 degC)
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
UNSPSC
39122001
Installation Guidelines
Verify Nameplate Identity and Supply Compatibility: Confirm that the received unit matches ACS880-04-880A-5 (3ABD00039385-D) and that the incoming three-phase supply (380 to 500 V AC, 47.5 to 63 Hz) and motor load profile match the selected normal, light-overload, or heavy-duty ratings.
Use Rated Rigging and Lifting Equipment: Because the drive module has a net weight of 199 kg and stands 1741 mm tall, use certified mechanical lifting gear during unpacking and cabinet installation.
Prepare Enclosure and Thermal Management: Install the IP20 / NEMA Open Type module inside a clean, dry electrical enclosure. Configure narrow bookshelf, flat, or horizontal mounting according to panel layout and airflow paths, ensuring cabinet ventilation maintains ambient air between -15 degC and 40 degC while dissipating up to 11206 W of heat loss at full rated load.
Position the Control Unit: Mount the control unit either directly on the power module or externally inside the cabinet to optimize access for control I/O and communication cabling.
Terminate Power Conductors and Grounding: Route incoming mains and outgoing motor cables according to the chosen cabling direction. Bond the module chassis solidly to the cabinet protective earth (PE) busbar and apply 360-degree shield terminations on motor cables to contain high-frequency interference.
Install Optional Hardware Modules: Secure any required optional accessories--such as a brake chopper, EMC filter, communication protocol adapter, functional safety module, or I/O extension module--prior to applying control power.
Commissioning and Replacement Guidelines
Pre-Energization Insulation Testing: Perform phase-to-phase and phase-to-ground insulation resistance checks on the motor and power cabling before connecting conductors to the drive module.
Parameter Backup and Control Unit Transfer: When replacing an existing ACS880-04-880A-5 unit, back up the complete drive parameter set, motor model data, and network settings beforehand, or transfer the existing undamaged control unit onto the replacement power module.
Motor Data Entry and Duty Selection: Program exact motor nameplate parameters, select the matching load duty profile (normal use, light-overload, or heavy-duty), and execute a motor identification run prior to normal operation.
Control Interlock and Safety Verification: Verify external start/stop interlocks, control I/O signals, fieldbus communication, and any installed functional safety modules at reduced speed before returning equipment to full production.
FAQ
What are the power and current ratings of the ABB ACS880-04-880A-5 for different load duties?
The drive module is rated for 630 kW and 880 A in normal use, 560 kW and 857 A in light-overload duty, and 500 kW and 697 A in heavy-duty operation. It operates on a three-phase 380 to 500 V AC input supply at 47.5 to 63 Hz.
Does the ACS880-04-880A-5 include a built-in harmonic choke or require external filtering?
A choke for harmonic filtering is built into the drive module as standard equipment. Additional components such as a brake chopper, EMC filter, communication protocol adapter, functional safety modules, and I/O extension modules are available as configurable options.
What mounting orientations and enclosure protection apply to the 3ABD00039385-D drive module?
The module carries an IP20 (NEMA Open Type) protection rating and must be installed inside a suitable electrical cabinet. It supports narrow bookshelf, flat, and horizontal mounting positions with flexible cabling directions, and its control unit can be mounted internally or externally.
How much heat loss does the ABB ACS880-04-880A-5 produce for cabinet cooling sizing?
The IE2-classified drive has a 713 W standby loss and achieves 98.2% efficiency at 90% frequency under 50% to 100% load current. At 90% frequency and 100% current, total power loss reaches 11206 W within a -15 degC to 40 degC ambient rating.
What steps should maintenance teams follow when replacing an ACS880-04-880A-5 drive module?
Verify the replacement unit matches model ACS880-04-880A-5 and Product ID 3ABD00039385-D, and use rated lifting equipment for the 199 kg chassis. Back up existing parameters or transfer the control unit, test motor cable insulation, and confirm duty settings before startup.
A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.
A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.
A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.