ABB

ABB PSTX840-600-70 1SFA898119R7000 Softstarter

SKU 1SFA898119R7000

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: 1SFA898119R7000

  • Country of origin:Sweden

  • Product Type: Three-Phase Softstarter

  • Payment: T/T, Western Union

  • Weight: 46500g

  • Dimensions: 435 mm x 493 mm x 369 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ABB PSTX840-600-70 (product ID 1SFA898119R7000 / 1SFA 8981 19 R7000) is a three-phase PSTX series softstarter engineered for controlled starting, stopping, and protection of medium- to large-sized three-phase AC induction motors. Operating across a main circuit voltage range of 208 to 600 V AC at 50/60 Hz with a 100 to 250 V AC control supply, the unit delivers a rated operational current of 840 A in an in-line connection (250 kW at 230 V, 450 kW at 400 V, and 600 kW at 500 V) or 1455 A in an inside-delta connection (450 kW at 230 V, 800 kW at 400 V, and 1000 kW at 500 V).

Equipped with three-phase voltage-ramp and torque-control algorithms, the PSTX840-600-70 integrates a built-in bypass contactor to minimize power losses during continuous running and simplify panel wiring. Operators interact via a detachable full-graphic display rated IP66 and UL Type 4X for outdoor panel mounting, while system integration is supported through hardwired Start/Stop/Reset inputs, three programmable digital inputs, four signaling relays, an analog output (0 to 10 V, 0 to 20 mA, or 4 to 20 mA), built-in Modbus RTU, and optional Anybus communication modules.

Features

  • Three-phase motor control supporting soft start and soft stop via voltage ramp or torque control
  • Built-in bypass for reduced heat dissipation, energy savings, and simplified cabinet installation
  • High current capacity rated at 840 A in-line and 1455 A inside-delta with a starting capacity of 4 x Ie for 10 seconds
  • Detachable full-graphic HMI display with IP66 and UL Type 4X outdoor environmental rating
  • Built-in electronic overload protection (EOL) with dual overload curves for start and run phases
  • Advanced motor control modes including kickstart, forward/reverse slow-speed jog, dynamic braking, standstill brake, pump cleaning, motor heating, sequence start, emergency/fire pump mode, and two-phase limp mode
  • Comprehensive electrical and thermal protection covering phase reversal, current/voltage imbalance, underload, locked rotor, ground fault, thyristor overload, and PTC/PT-100 temperature inputs
  • Built-in Modbus RTU communication plus support for optional Anybus modules (Profinet, Profibus, Modbus TCP, EtherNet/IP, EtherCAT, DeviceNet, CANopen, BACnet-IP, and BACnet-MSTP)
  • Four integrated status signaling relays (Run, By-pass/TOR, Fault, Overload) and configurable analog output (0 to 10 V, 0 to 20 mA, 4 to 20 mA)

Applications

  • Centrifugal and positive-displacement pumps, including municipal water systems and emergency/fire pump installations
  • Industrial ventilation fans, exhaust blowers, and HVAC air handling units
  • Rotary screw, reciprocating, and centrifugal air and gas compressors
  • Heavy-duty belt conveyors, crushers, and bulk material handling systems
  • High-inertia three-phase industrial machinery operating on 208 to 600 V AC mains

Technical Specifications

Attribute Specification
Manufacturer ABB
Model / Type Designation PSTX840-600-70
Product ID / Order Code 1SFA898119R7000 / 1SFA 8981 19 R7000
EAN 7320500510421
Product Series PSTX Softstarters (PSTX840)
Product Type Three-Phase Softstarter
Rated Operational Voltage 208 to 600 V AC
Rated Frequency 50/60 Hz (Main Circuit)
Rated Control Supply Voltage (Us) 100 to 250 V AC, 50/60 Hz
Rated Control Circuit Voltage (Uc) 24 V DC
Rated Operational Current - In-Line (Ie) 840 A
Rated Operational Power - In-Line (Pe) 250 kW (at 230 V); 450 kW (at 400 V); 600 kW (at 500 V)
Rated Operational Current - Inside Delta 1455 A
Rated Operational Power - Inside Delta 450 kW (at 230 V); 800 kW (at 400 V); 1000 kW (at 500 V)
UL/CSA Horsepower Rating (Three-Phase) 300 Hp (200 to 208 V AC); 350 Hp (220 to 240 V AC); 700 Hp (440 to 480 V AC); 800 Hp (550 to 600 V AC)
Maximum Operating Voltage (UL/CSA) 600 V (Main Circuit)
Service Factor 100%
Starting Capacity at Maximum Rated Current (Ie) 4 x Ie for 10 s
Ramp Time 1 to 120 s
Initial Voltage During Start 10 to 99 V
Step Down Voltage Special Ramp 100 to 10%
Current Limit Function 1.5 to 7.5 x Ie
Built-in Bypass Yes (with Inside Delta connection switch)
Overload Protection Built-in electronic overload protection (EOL), dual overload (start and run)
Signal Relays Run Signal Relay, By-pass (TOR) Signal Relay, Fault Signal Relay, Overload Signal Relay (NO contacts)
Analog Outputs 0 to 10 V, 0 to 20 mA, 4 to 20 mA
LED Status Indicators Ready to Start/Standby ON (Green), Running R (Green), Protection (Yellow), Fault (Red)
Communication Protocols Modbus-RTU (built-in); Modbus-TCP, EtherNet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, BACnet-MSTP (via Anybus / Fieldbus plug)
HMI Display Detachable full-graphic display (IP66 and UL Type 4X outdoor rating)
Main Circuit Terminal Type Busbars (Bars)
Tightening Torque (Main Circuit) 45 N-m (398.3 lb-in UL/CSA)
Connecting Capacity (Control & Supply Circuits) Rigid 1 x 2.5 mm2
Degree of Protection Main Terminals: IP00 (IEC 60529, IEC 60947-1, EN 60529); Graphic Display: IP66 / Type 4X
Ambient Operating Temperature -25 to +60 degC
Ambient Storage Temperature -40 to +70 degC
Dimensions (W x H x D) 435 mm x 493 mm x 369 mm
Net Weight 46.5 kg
Shipping Package Dimensions & Gross Weight 600 mm (W) x 616 mm (D) x 800 mm (H); 58.5 kg gross weight
Customs Tariff Number 85371091

Connections/Interfaces

Connector Pin Function
Main Power Busbars Three-phase line and motor load busbar connections rated up to 840 A in-line (1455 A inside-delta), tightened to 45 N-m
Control Supply Terminals (Us) 100 to 250 V AC (50/60 Hz) auxiliary control power input accepting rigid 1 x 2.5 mm2 conductors
Control Circuit & Digital Inputs (Uc) 24 V DC control circuit with hardwired Start, Stop, Fault Reset, and three programmable digital inputs (rigid 1 x 2.5 mm2)
Signal Output Relays Normally Open (NO) relay outputs for Run, By-pass / Top of Ramp (TOR), Fault, and Overload status indication
Analog Output Terminals Configurable analog feedback output supporting 0 to 10 V, 0 to 20 mA, or 4 to 20 mA signals
Temperature Sensor Inputs Dedicated motor thermal protection inputs supporting PTC and PT-100 sensors
Built-in Fieldbus Interface Integrated Modbus RTU serial communication interface and external Fieldbus plug adaptor support (PS-FBPA)
Anybus & HMI Expansion Ports Front expansion slot for optional Anybus industrial Ethernet/fieldbus modules and port for the detachable IP66 graphic display or PSCA-1 USB cable

Installation Guidelines

  • Enclosure Protection: Because the main power terminals carry an IP00 protection rating, install the softstarter inside a suitable industrial control enclosure; optionally fit terminal shrouds (LT750-AC / LT750-AL) and terminal enlargements (LW750) or CuAl cable lug kits (1SDA013956R1 / 1SDA023380R1) for finger protection and conductor termination.
  • Busbar & Control Wiring Torque: Tighten main circuit busbar connections to 45 N-m (398.3 lb-in per UL/CSA specifications) and terminate control/supply wiring using rigid 1 x 2.5 mm2 conductors.
  • Connection Configuration: Select between standard in-line connection (up to 840 A) and inside-delta connection (up to 1455 A) using the integrated inside-delta configuration switch prior to commissioning.
  • Remote HMI Mounting: Detach the IP66 / Type 4X rated graphic display from the softstarter body and mount it on the cabinet door for external operator access and diagnostics without opening the enclosure.
  • Thermal Clearance & Operating Environment: Maintain ambient air temperatures within -25 to +60 degC inside the panel during operation.

Compliance and Certifications

  • CE: Compliant with European Union directives (Declaration of Conformity 2CMT005209)
  • UL / cULus: Rated for UL/CSA three-phase motor control up to 600 V AC and 800 Hp
  • CCC and CQC: Certified under China Compulsory Certification (2020980304001095 / 2020980304001491) and CQC (CQC2015010304830300 / CQC2015010304830295)
  • DNV: Marine and offshore type approval certificate TAE000087N
  • RoHS and REACH: Compliant with EU RoHS Directive 2011/65/EU and Amendment 2015/863 (2CMT2022-006500), EU REACH (2CMT2022-006481), and US TSCA (2CMT2023-006524)
  • Environmental & Data Compliance: ABB EcoSolutions validated with 81.9% recyclability per EN 45555, WEEE Category 5 B2B compliance, and EU Data Act compliance (1SFC132498M0201)

FAQ

What are the current and power ratings for the ABB PSTX840-600-70 softstarter?

The ABB PSTX840-600-70 (1SFA898119R7000) is rated for 840 A in an in-line connection (250 kW at 230 V, 450 kW at 400 V, 600 kW at 500 V) and up to 1455 A in an inside-delta connection (450 kW at 230 V, 800 kW at 400 V, 1000 kW at 500 V).

Does the PSTX840-600-70 include a built-in bypass and electronic overload protection?

Yes, the softstarter features an integrated bypass contactor to reduce running energy losses along with built-in dual electronic overload protection (EOL) for both start and run phases.

What communication protocols and control voltages are supported by 1SFA898119R7000?

It operates on a 100 to 250 V AC (50/60 Hz) control supply with a 24 V DC control circuit, includes built-in Modbus RTU, and supports Anybus modules for Profinet, Profibus, Modbus TCP, EtherNet/IP, EtherCAT, DeviceNet, CANopen, and BACnet.

Can the graphic display on the PSTX840-600-70 be mounted on a panel door?

Yes, the softstarter includes a detachable full-graphic display rated IP66 and UL Type 4X for outdoor and cabinet door mounting.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB PSTX840-600-70 1SFA898119R7000 Softstarter

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 2
Only 20 item(s) left in stock
Quantity
View full details
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.