ABB

ABB AO810V2 3BSE038415R1 S800 I/O Analog Output Module

SKU 3BSE038415R1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: 3BSE038415R1

  • Country of origin:Sweden

  • Product Type: Analog Output Modules

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 250 mm x 120 mm x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for seamless integration into S800 I/O systems, the ABB AO810V2 (part number 3BSE038415R1) delivers reliable analog control signal generation for process automation applications. This module functions as an industrial-grade interface that converts digital controller commands into standard analog output current signals, allowing precise command of field instruments such as control valves, actuators, positioners, and variable speed drives.

The 3BSE038415R1 is characterized by its robust construction, electrical isolation, and high-density design, making it a reliable component for both small-scale machine control and large distributed control systems (DCS). Operating within the S800 I/O platform, it communicates directly with ABB Advant and System 800xA controllers, offering diagnostics and configuration options directly from the engineering workstation.

Features

  • Provides multiple high-accuracy analog output channels for flexible device control.
  • Features galvanic isolation between the field circuits and the internal system backplane to protect control electronics.
  • Short-circuit proof outputs prevent damage from field wiring faults.
  • Supports Hot Swap (Removal and Insertion Under Power) when paired with compatible Module Termination Units (MTUs).
  • Front-panel status indicators provide real-time diagnostic status and fault alerts.

Applications

  • Control valve and positioning actuator management in oil, gas, and chemical refineries.
  • Speed reference distribution for variable frequency drives (VFDs) in water treatment facilities.
  • Process loop control in power generation and utility plants.
  • General manufacturing and pulp and paper automation systems.

Technical Specifications

Manufacturer ABB
Part Number / Model AO810V2 / 3BSE038415R1
Series S800 I/O
Module Type Analog Output Module
Output Current Range 0 to 20 mA, 4 to 20 mA
Product Lifecycle Phase Active
Weight 0.50 kg
Dimensions (W x H x D) 250 mm x 120 mm x 100 mm

Installation Guidelines

To ensure optimal performance and safe operation of the 3BSE038415R1 Analog Output Module, observe the following electrical and physical installation procedures:

  • Mounting: Securely latch the module onto its designated S800 Module Termination Unit (MTU) mounted on a standard 35mm DIN rail. Ensure the MTU is correctly grounded before sliding the module into place.
  • Shielding: Use twisted-pair, shielded cables for all analog signal runs. Ground the cable shields at only one end (typically at the cabinet entry or terminal block) to avoid ground loops.
  • Wiring Separation: Route analog signal cables away from high-voltage AC power lines and motor drive cables to reduce electromagnetic interference.
  • Ventilation: Provide adequate spacing within the enclosure to maintain an operating temperature within standard specified S800 environmental thresholds. Do not block air vents.

FAQ

What is the main function of the ABB AO810V2 module?

The ABB AO810V2 (3BSE038415R1) is an analog output module designed to convert digital signals from an S800 I/O controller into standard analog currents (0-20 mA or 4-20 mA) for field devices like actuators and control valves.

Does the 3BSE038415R1 module support hot-swapping?

Yes, the AO810V2 supports hot-swapping (removal and insertion under power) when utilized with a compatible S800 Module Termination Unit (MTU).

What are the transport dimensions and weight of this item?

The module has a shipping weight of approximately 0.50 kg and outer dimensions of 25 cm x 12 cm x 10 cm.

Which PLC/DCS systems is the AO810V2 compatible with?

The module is fully compatible with ABB S800 I/O systems, which integrate into Advant OCS and System 800xA control platforms.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Technical knowledge

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...