The ABB NKST11-15 is a prefabricated sequence of events (SOE) digital input and time synchronization termination unit (TU) cable designed for high-precision temporal tracking in process automation environments. This SOE Time Synch Cable spans a length of 15 feet and is engineered specifically to connect the SET SOE digital input module to the NTST termination unit. Built with a halogen-free, non-PVC outer jacket, the NKST11-15 matches rigid environmental and safety standards by minimizing toxic smoke emissions during thermal events. It provides a dedicated communication interface to ensure microsecond-level time stamp synchronization across the Symphony Harmony INFI 90 control architecture.

Features

  • Prefabricated design equipped with reliable factory connectors to ensure plug-and-play field setup.
  • Formulated with non-PVC, halogen-free insulation materials for specialized environmental safety requirements.
  • Fixed 15-foot physical cable configuration optimizing signal delivery parameters between target modules.
  • Designed exclusively to integrate the IMSET01 or equivalent SET digital input modules with the companion NTST unit.

Applications

  • Symphony Harmony INFI 90 Sequence of Events (SOE) recording structures.
  • Precision time synchronization links within Distributed Control Systems (DCS).
  • High-security plant control rooms requiring low-smoke halogen-free infrastructure.

Technical Specifications

Parameter Value
Manufacturer ABB 
Product ID NKST11-15 
ABB Type Designation NKST11-15 
Product Type Prefabricated_Cable 
Product Net Depth / Length 127 mm 
Product Net Height 508 mm 
Product Net Width 254 mm 
Product Net Weight 0.1 kg 
Cable Diameter 0.127 mm 
Voltage Limit Not exceeding 1000 V 
Customs Tariff Number 85444290 
HS Code 854442 
WEEE Category Product Not in WEEE Scope 

Installation Guidelines

  • Cable Routing: Plan paths properly to protect the 0.127 mm diameter cable assembly from sharp corners and sharp mechanical stress.
  • Interface Allocation: Ensure the connection directly mapping from the SET module matches the dedicated pins on the NTST assembly without tension.
  • Environmental Integrity: Maintain standard cabinet operating boundaries as the cable material contains a halogen-free specialized matrix.

FAQ

What modules are interconnected using this cable assembly?

The cable is specifically designed to connect the SET module to the NTST unit within the control system architecture.

Does this cable jacket contain polyvinyl chloride?

No, the cable construction uses a non-PVC, halogen-free insulation compound for enhanced safety.

What is the maximum operating voltage supported by the cable structure?

The cable is rated for an operating voltage that does not exceed 1000 V.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB NKST11-15 Symphony Harmony INFI 90 SOE DI and Time Synch Module TU Cable

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Sweden

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.