Implementing 3-Switch XOR Ladder Logic with Internal Bit
Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.
The S202-K4 electrical assembly with Product ID 2CDS252001R0337 is a current-limiting 2-pole miniature circuit breaker designed for overcurrent and short-circuit fault management in power distribution networks. This device incorporates two alternative activation mechanisms: a delayed thermal tripping mechanism for targeted overload protection and an electromechanical magnetic tripping mechanism for rapid short-circuit mitigation. Built within the S200 product range, it features a K-characteristic curve optimized to safeguard circuitry while handling inductive current inrushes without nuisance tripping. It is suitable for deployment across residential, commercial, and diverse industrial infrastructure applications.
| Parameter | Value |
|---|---|
| Extended Product Type | S202-K4 |
| Product ID | 2CDS252001R0337 |
| EAN | 4016779507363 |
| Package Level 1 Units | carton 5 piece |
| Parameter | Specification |
|---|---|
| Manufacturer | ABB |
| Product ID | 2CDS252001R0337 |
| Extended Product Type | S202-K4 |
| Catalog Description | Miniature Circuit Breaker-S200-2P-4A-K-(AC) 6 KA |
| Number of Protected Poles | 2 |
| Number of Poles | 2P |
| Tripping Characteristic | K |
| Rated Current (In) | 4 A |
| Input Voltage Type | AC/DC |
| Rated Operational Voltage | acc. to IEC 60947-2 440 V AC |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Short-Circuit Capacity | (AC) 6 kA, (DC) 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 20 kA, (400 V AC) 10 kA, (440 V AC) 10 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 15 kA, (400 V AC) 7.5 kA, (440 V AC) 7.5 kA |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 440 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Power Loss | 3.4 W (at Rated Operating Conditions per Pole 1.7 W) |
| Energy Limiting Class | 3 |
| Electrical Endurance | 20000 AC cycle |
| Mechanical Endurance | 20000 cycle |
| Housing Material | Insulation Group II, RAL 7035 |
| Degree of Protection | IP20, IP40 (Enclosure with Cover IP40) |
| Pollution Degree | 3 |
| Ambient Air Temperature | Operation -25 ... +55 degC, Storage -40 ... +70 degC |
| Width in Number of Modular Spacings | 2 |
| Product Net Width | 35 mm |
| Product Net Height | 88 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 0.224 kg |
Global Express Shipping
Returns & Warranty



The S202-K4 electrical assembly with Product ID 2CDS252001R0337 is a current-limiting 2-pole miniature circuit breaker designed for overcurrent and short-circuit fault management in power distribution networks. This device incorporates two alternative activation mechanisms: a delayed thermal tripping mechanism for targeted overload protection and an electromechanical magnetic tripping mechanism for rapid short-circuit mitigation. Built within the S200 product range, it features a K-characteristic curve optimized to safeguard circuitry while handling inductive current inrushes without nuisance tripping. It is suitable for deployment across residential, commercial, and diverse industrial infrastructure applications.
| Parameter | Value |
|---|---|
| Extended Product Type | S202-K4 |
| Product ID | 2CDS252001R0337 |
| EAN | 4016779507363 |
| Package Level 1 Units | carton 5 piece |
| Parameter | Specification |
|---|---|
| Manufacturer | ABB |
| Product ID | 2CDS252001R0337 |
| Extended Product Type | S202-K4 |
| Catalog Description | Miniature Circuit Breaker-S200-2P-4A-K-(AC) 6 KA |
| Number of Protected Poles | 2 |
| Number of Poles | 2P |
| Tripping Characteristic | K |
| Rated Current (In) | 4 A |
| Input Voltage Type | AC/DC |
| Rated Operational Voltage | acc. to IEC 60947-2 440 V AC |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Short-Circuit Capacity | (AC) 6 kA, (DC) 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 20 kA, (400 V AC) 10 kA, (440 V AC) 10 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 15 kA, (400 V AC) 7.5 kA, (440 V AC) 7.5 kA |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 440 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Power Loss | 3.4 W (at Rated Operating Conditions per Pole 1.7 W) |
| Energy Limiting Class | 3 |
| Electrical Endurance | 20000 AC cycle |
| Mechanical Endurance | 20000 cycle |
| Housing Material | Insulation Group II, RAL 7035 |
| Degree of Protection | IP20, IP40 (Enclosure with Cover IP40) |
| Pollution Degree | 3 |
| Ambient Air Temperature | Operation -25 ... +55 degC, Storage -40 ... +70 degC |
| Width in Number of Modular Spacings | 2 |
| Product Net Width | 35 mm |
| Product Net Height | 88 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 0.224 kg |
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Germany
|