Description

The S2C-S/H6R universal contact with Product ID 2CDS200922R0001 is a high-reliability universal auxiliary/signal contact mechanical assembly designed for low-voltage modular DIN rail systems. This component allows an operator or system logic to choose via an integrated manual selector switch between indicating the precise contact position of the primary device or signaling a distinct electrical fault, such as an overcurrent or short-circuit event. It is engineered for seamless system compatibility across a broad selection of modular hardware including S200 series miniature circuit breakers, residual current devices, and switches.

Features

  • Equipped with a built-in selector switch to toggle functions between contact position indication and fault signaling.
  • Features 1 changeover contact (SPDT/CO configuration) for flexible control loop interfacing.
  • Provides high-efficiency operation with a maximum low power loss rating of 0.5 W.
  • Designed for standard right-side mounting positions on compatible protection modules.

Applications

  • Remote electrical position status and fault alarm signaling in industrial automation control panels.
  • Low-voltage commercial and residential distribution board monitoring systems.
  • Auxiliary contact status feedback in motor branch control loops.

Ordering Information

Parameter Value
Extended Product Type S2C-S/H6R
Product ID 2CDS200922R0001
EAN 4016779563819
Minimum Order Quantity 1 piece

Technical Specifications

Parameter Specification
Manufacturer ABB
Product ID 2CDS200922R0001
Extended Product Type S2C-S/H6R
Function Signal/Auxiliary Contact
Suitable For S200, S200M, S200MT, S300P, F200, DS201, SD200, DS200, S-ARC1, DS-ARC1
Suitable for Product Class Miniature Circuit Breaker, Residual Current Device
Number of Auxiliary Contacts NC 0
Number of Auxiliary Contacts NO 0
Number of Auxiliary Contacts CO (SPDT) 1
Power Loss 0.5 W (Maximum 0.5 W)
Product Net Width 8.8 mm
Product Net Height 85 mm
Product Net Depth / Length 69 mm
Product Net Weight 0.043 kg
Package Level 1 Units blister 1 piece
Package Level 1 Gross Weight 0.045 kg

Installation Guidelines

  • Mounting Position: Attach the mechanical accessory directly to the right side of the compatible primary circuit breaker or residual current device.
  • DIN Rail Installation: Mount alongside the master device onto a standard symmetrical DIN rail track arrangement.
  • Wiring Configurations: Connect external signal circuitry to the integrated screw terminal blocks according to the required contact signaling logic.

Compliance and Certifications

  • Declaration of Conformity CE: 9AKK108468A4564
  • Standards: CSA 22.2 No. 235, GB/T 14048.5, IEC/EN 60947-5-1, UL 1077
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the function of the selector on this accessory?
The selector allows the user to choose between contact position indication and fault signaling for overcurrent, short-circuit, or earth faults.
Which side of the primary circuit breaker should the device be mounted on?
The device is specifically designed for a right-side mounting position relative to the compatible circuit breaker.
What is the contact configuration provided by the device?
The device features 1 changeover contact, also referred to as a single-pole double-throw or SPDT configuration.
Reviews

S2C-S/H6R 2CDS200922R0001

Stock & lead time on request

Call
1 of 4

ABB S2C-S/H6R 2CDS200922R0001 Universal Auxiliary/Signal Contact

  • Manufacturer: ABB

  • Product No.: S2C-S/H6R 2CDS200922R0001

  • Country of origin:Germany

  • Product Type: Auxiliary Contact Blocks

  • Payment: T/T, Western Union

  • Weight: 43g

  • Dimensions: 69 mm x 8.8 mm x 85 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The S2C-S/H6R universal contact with Product ID 2CDS200922R0001 is a high-reliability universal auxiliary/signal contact mechanical assembly designed for low-voltage modular DIN rail systems. This component allows an operator or system logic to choose via an integrated manual selector switch between indicating the precise contact position of the primary device or signaling a distinct electrical fault, such as an overcurrent or short-circuit event. It is engineered for seamless system compatibility across a broad selection of modular hardware including S200 series miniature circuit breakers, residual current devices, and switches.

Features

  • Equipped with a built-in selector switch to toggle functions between contact position indication and fault signaling.
  • Features 1 changeover contact (SPDT/CO configuration) for flexible control loop interfacing.
  • Provides high-efficiency operation with a maximum low power loss rating of 0.5 W.
  • Designed for standard right-side mounting positions on compatible protection modules.

Applications

  • Remote electrical position status and fault alarm signaling in industrial automation control panels.
  • Low-voltage commercial and residential distribution board monitoring systems.
  • Auxiliary contact status feedback in motor branch control loops.

Ordering Information

Parameter Value
Extended Product Type S2C-S/H6R
Product ID 2CDS200922R0001
EAN 4016779563819
Minimum Order Quantity 1 piece

Technical Specifications

Parameter Specification
Manufacturer ABB
Product ID 2CDS200922R0001
Extended Product Type S2C-S/H6R
Function Signal/Auxiliary Contact
Suitable For S200, S200M, S200MT, S300P, F200, DS201, SD200, DS200, S-ARC1, DS-ARC1
Suitable for Product Class Miniature Circuit Breaker, Residual Current Device
Number of Auxiliary Contacts NC 0
Number of Auxiliary Contacts NO 0
Number of Auxiliary Contacts CO (SPDT) 1
Power Loss 0.5 W (Maximum 0.5 W)
Product Net Width 8.8 mm
Product Net Height 85 mm
Product Net Depth / Length 69 mm
Product Net Weight 0.043 kg
Package Level 1 Units blister 1 piece
Package Level 1 Gross Weight 0.045 kg

Installation Guidelines

  • Mounting Position: Attach the mechanical accessory directly to the right side of the compatible primary circuit breaker or residual current device.
  • DIN Rail Installation: Mount alongside the master device onto a standard symmetrical DIN rail track arrangement.
  • Wiring Configurations: Connect external signal circuitry to the integrated screw terminal blocks according to the required contact signaling logic.

Compliance and Certifications

  • Declaration of Conformity CE: 9AKK108468A4564
  • Standards: CSA 22.2 No. 235, GB/T 14048.5, IEC/EN 60947-5-1, UL 1077

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB S2C-S/H6R 2CDS200922R0001 Universal Auxiliary/Signal Contact

What is the function of the selector on this accessory?

The selector allows the user to choose between contact position indication and fault signaling for overcurrent, short-circuit, or earth faults.

Which side of the primary circuit breaker should the device be mounted on?

The device is specifically designed for a right-side mounting position relative to the compatible circuit breaker.

What is the contact configuration provided by the device?

The device features 1 changeover contact, also referred to as a single-pole double-throw or SPDT configuration.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...