Product Overview

The AH04TC-5A (AH04TC5A) is a high-performance 4-channel temperature measurement module designed for the Delta AH500 modular PLC system. This module is engineered for high-precision thermal monitoring and control in demanding industrial processes such as plastic extrusion, heat treatment, and chemical reactors. It supports a wide range of thermocouple types (J, K, R, S, T, E, N) and low-voltage signals (±150mV) with an effective 16-bit resolution. The AH04TC-5A is built for mission-critical reliability, featuring hot-swapping capabilities, signal isolation, and a built-in PID control function, allowing it to manage temperature loops independently of the main CPU's scan cycle.

Technical Configuration

The hardware of the AH04TC-5A is designed for maximum signal integrity and system uptime. It utilizes a JIS removable terminal block, which simplifies maintenance and field wiring. The module provides a fast conversion time of 200ms per channel, ensuring responsive data acquisition for dynamic temperature changes. Its isolated signal design protects the internal PLC backplane from field-side electrical interference. Advanced diagnostic capabilities are integrated, including disconnection detection to immediately alert operators if a thermocouple probe fails, and module status LEDs for instant local troubleshooting.

Technical Specifications

Attribute Specification Details
Model AH04TC-5A
Brand DELTA
Series AH500 Series
Number of Channels 4
Input Signals J, K, R, S, T, E, N Thermocouples; ±150mV
Effective Resolution 16-bit (0.1°C / 0.1°F)
Accuracy ±0.6% of Full Scale
Conversion Time 200 ms / channel
Terminal Block JIS Removable Type
Power Consumption 1.5 W (Internal)
Control Function Built-in PID
Special Functions Hot-swapping, Disconnection Detection, Interrupts
Shipping Weight 2.0 kg

Technical FAQs

Does the AH04TC-5A support Cold Junction Compensation (CJC)?

Yes. To maintain high accuracy, the module includes internal cold junction compensation to account for the temperature at the terminal block where the thermocouple wires connect. This ensures that the voltage-to-temperature conversion remains precise across varying ambient conditions.

What is the benefit of the "Hot-swapping" function in the AH500 series?

The AH04TC-5A is designed for high-availability systems. Hot-swapping allows you to replace a faulty temperature module without powering down the entire PLC rack or stopping the process. This is critical for continuous manufacturing lines where downtime results in significant material loss.

How does the PID function work within the module itself?

Instead of the PLC CPU performing all PID calculations, the AH04TC-5A can be configured to handle PID loops locally. This reduces the processing load on the main CPU and ensures that temperature control continues smoothly even if the CPU scan time increases due to complex logic elsewhere in the program.


Engineering & Installation Guide

  • Thermocouple Wiring: When wiring the 4 channels, always use the correct compensation wire for the specific thermocouple type being used. Mixing wire types or using standard copper wire will introduce significant measurement errors. Ensure that the polarity (Positive/Negative) is strictly observed at the JIS terminal block.

  • Noise Mitigation: To achieve the rated ±0.6% accuracy, keep thermocouple leads away from high-voltage AC power lines and Variable Frequency Drives (VFDs). If the environment is electrically noisy, utilize the module's built-in digital filtering settings via the AH500 configuration software.

  • Disconnection Detection: Enable the "Disconnection Detection" function in the module parameters. This will allow the PLC to trigger a safety routine (such as shutting down heaters) immediately if a sensor wire is broken, preventing uncontrolled heating.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.