Allen-Bradley

Allen-Bradley 1753-L32BBBM-8A GuardPLC 1800 Safety Controller

SKU 1753-L32BBBM-8A

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 1753-L32BBBM-8A

  • Country of origin:United States

  • Product Type: Safety Controller

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1250g

  • Dimensions: 152 mm x 177 mm x 135 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Allen-Bradley 1753-L32BBBM-8A is a safety-related programmable logic controller within the GuardPLC 1800 series, featuring integrated safety digital, analog, and high-speed counter inputs, digital outputs, and embedded communication interfaces. Designed for fail-safe CPU applications meeting IEC 61508 (SIL 3) and ISO 13849-1 (PLe/Cat. 4) standards, the unit processes safety-critical signals while continuously monitoring execution timing and hardware/software self-tests. The controller integrates four 10/100BaseT RJ-45 Ethernet ports via an internal switch for safety-rated peer-to-peer networking, EtherNet/IP communications, and programming. Non-safety serial communications are supported through RS-485 interfaces, including Modbus RTU Slave on COMM1 and GuardPLC ASCII/High-Speed Safety Protocol (HSP) on COMM3.

Features

  • Integrated on-board safety I/O including 24 digital inputs, 8 digital outputs, 8 safety-related analog inputs, and 2 high-speed counters.
  • Four 10/100BaseT RJ-45 Ethernet ports operating through an internal Ethernet switch with auto-crossing detection for full- and half-duplex communication.
  • Integrated serial communication ports supporting Modbus RTU Slave protocol (COMM1) and GuardPLC ASCII/HSP protocols (COMM3).
  • Dual safety certification compliance for SIL 3 according to IEC 61508 and PLe/Cat. 4 according to ISO 13849-1.
  • Automated fault detection handling for permanent and transient I/O faults, directing channels or modules to a defined safe state (value 0 / de-energized).
  • Recessed hardware reset pushbutton for temporarily restoring default IP addresses, system resource settings, and login credentials.

Applications

  • Safety-instrumented systems (SIS) and emergency shutdown applications requiring SIL 3 / PLe Cat. 4 integrity.
  • Industrial safety control environments utilizing distributed safety I/O and peer-to-peer Ethernet networks.
  • Automation systems requiring combined digital, analog, and high-speed counter processing in a single safety unit.
  • Integrated safety systems requiring Modbus RTU Slave or HSP communication with external scanners and controllers.

Technical Specifications

Specification Value
Manufacturer Allen-Bradley / Rockwell Automation
Product Family GuardPLC 1800
Catalog / Orderable Model 1753-L32BBBM-8A
Safety Rating SIL 3 (IEC 61508), PLe/Cat. 4 (ISO 13849-1)
Operating Voltage Range 20.4 to 28.8V DC
Digital Inputs 24
Digital Outputs 8
Analog Inputs 8 safety-related
High-Speed Counters 2
Ethernet Ports 4 x RJ-45 (10/100BaseT, internal switch)
Serial COMM1 Interface RS-485 (Modbus RTU Slave)
Serial COMM2 Interface Not used
Serial COMM3 Interface RS-485 (GuardPLC ASCII / HSP)

Connections/Interfaces

Connector Pin Function
COMM1 / COMM3 (Min-D 9-Pin RS-485)  
Pin 1 Unassigned
Pin 2 RP 5V, decoupled with diodes
Pin 3 RxD/TxD-A Receive/Transmit data A
Pin 4 CNTR-A Control Signal A
Pin 5 DGND Data reference potential
Pin 6 VP 5V, positive pole of supply voltage
Pin 7 Unassigned
Pin 8 RxD/TxD-B Receive/Transmit data B
Pin 9 CNTR-B Control Signal B

Installation Guidelines

  • Mounting Orientation: Mount the controller horizontally to a zinc-plated yellow-chromate steel DIN rail to ensure effective cooling and continuous grounding.
  • Clearance Requirements: Provide a clearance gap of at least 100 mm (3.94 in.) above and below the device and at least 20 mm (0.79 in.) horizontally between devices.
  • Ventilation: Ensure air flows freely around the unit, avoid blocking side ventilation slots, and do not mount directly above heating elements.
  • Wire Duct Spacing: Wire ducts located in the clearance area must not exceed a depth of 40 mm (1.58 in.); if deeper than 40 mm, mount devices on stand-offs matching the duct depth or maintain an 80 mm (3.15 in.) gap.
  • Network Wiring: Use either straight-through or cross-over Ethernet cables for RJ-45 ports; ensure network loops are prevented so data packets reach nodes via a single path.

FAQ

What safe state do the controller outputs default to in the event of a system fault?

When a fault occurs, the outputs are de-energized and switched off to a safe value of 0.

Which serial communication protocols are supported on COMM1 and COMM3 interfaces?

COMM1 supports Modbus RTU Slave protocol, while COMM3 supports GuardPLC ASCII protocol and High-Speed Safety Protocol (HSP).

What type of DIN rail is required for proper grounding of the module?

The device grounds through the rail and requires zinc-plated yellow-chromate steel DIN rails to ensure proper grounding.

What happens when the hardware reset pushbutton is pressed during a power cycle?

Holding the reset pushbutton during restart temporarily resets the IP address to 192.168.0.99, SRS to 60000.1, and sets the login credentials to default settings.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1753-L32BBBM-8A GuardPLC 1800 Safety Controller

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.