Allen-Bradley

Allen-Bradley 1715-OB8DE 1715 Redundant I/O Digital Output Module

SKU 1715-OB8DE

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 1715-OB8DE

  • Country of origin:United States

  • Product Type: Digital Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 290g

  • Dimensions: 166 mm x 42 mm x 118 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The 1715-OB8DE is a digital output module designed for high-availability industrial automation applications within the Allen-Bradley 1715 Redundant I/O System. Operating on a backplane supply voltage range of 18…32V DC, the module provides 8 digital output channels for controlling field devices. It interfaces with process control systems using the 1715-A3IO module base unit and either the 1715-TASOB8DE or 1715-TADOB8DE termination assemblies. Built with conformal coating, the module delivers fault-tolerant performance and integrated diagnostics suitable for critical control systems, safety instrumented systems (SIS), and hazardous location applications.

Features

  • Provides 8 digital output channels with standard output functionality.
  • Integrates directly into the 1715 Redundant I/O System via the 1715-A3IO module base.
  • Supports fault-tolerant operation when paired with compatible 1715 termination assemblies.
  • Features status indicator LEDs for module health, system readiness, and operational status.
  • Operates in harsh environments with conformal coating meeting ANSI/ISA-S71.04-2013 Class G1, G2, and G3 standards.
  • Accommodates field-side fused protection on compatible termination assemblies.

Applications

  • Oil and gas emergency shutdown (ESD) systems
  • Process safety instrumented systems (SIS)
  • Power generation plant control
  • Chemical and petrochemical production automation
  • Critical infrastructure and high-availability process automation

Ordering Information

Catalog Number Description
1715-OB8DE Digital Output Module, 8 Channels, Redundant I/O
1715-A3IO 3-Slot Module Base Unit
1715-TASOB8DE Simplex Digital Output Termination Assembly
1715-TADOB8DE Duplex Digital Output Termination Assembly

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Module Type Digital Output Module
Operating Voltage Range (Backplane) 18…32V DC
Backplane Current 165 mA @ 18…32V DC
Field Channel Rating 0.5 A per channel @ 18…32V DC
Field Voltage Slew Rate (Max) 150 V/s
De-energized Output Voltage Slew Rate (Max) 12 V/ms
Energized Output Current Slew Rate (Max) 0.9 A/ms
Power Dissipation (System) 3.0 W max
Power Dissipation (Field Loop) 0.17 W per field loop
Isolation Voltage 50V (continuous), basic insulation type, I/O ports to backplane; type tested at 500V AC for 60 s
Individual Port Isolation No isolation between individual I/O ports
Module Weight 290 g (10.23 oz)
I/O Base Unit Weight 133 g (5 oz)
Termination Assembly Weight 133 g (5 oz) / 260 g (10 oz)
Dimensions (H x W x D) 166 x 42 x 118 mm (6.5 x 1.625 x 4.625 in.)
Wire Size (Termination Assembly) Single 0.75…1.5 mm2 (18…16 AWG) solid or stranded copper wire rated at 85 degC (185 degF) or greater
Wiring Category 2 - on signal ports
Fuse Type (1715-TASOB8DE/TADOB8DE) I/O: 10 A, 125V, Type F; Power Source: 5 A max, 32V DC, min
Pilot Duty Rating 16VA, 1.5 inrush
Temperature Code T4 (North American and IEC)
Enclosure Type None (open-style)
Operating Temperature -25…60 degC (-13…140 degF)
Surrounding Air Temperature (Max) 70 degC (158 degF)
Nonoperating Temperature -40…85 degC (-40…185 degF)
Relative Humidity 10…95% noncondensing
Operating Vibration 2 g @ 10…500 Hz
Operating Shock DIN rail mount: 25 g; Panel mount: 30 g
Nonoperating Shock Installed: 30 g; Uninstalled: 50 g (with slot fillers)

Installation Guidelines

  • DIN Rail and Panel Mounting: Secure the 1715-A3IO base unit to the DIN rail or panel prior to inserting the module. Maintain proper panel clearance for heat dissipation.
  • Wiring and Field Connections: Route field wiring using single 0.75…1.5 mm2 (18…16 AWG) solid or stranded copper conductors rated for at least 85 degC. Ensure category 2 conductor routing practices are applied to signal ports.
  • Enclosure Requirements: Install the module inside an industrial enclosure providing appropriate protection for open-style equipment in hazardous or harsh environments.
  • Power Supply and Fusing: Connect field power within the 18…32V DC range. Ensure the termination assembly fuses (10 A, 125V Type F for I/O; 5 A max, 32V DC for power) are correctly rated prior to energizing.

Compliance and Certifications

  • cULus: UL Listed Industrial Control Equipment for US and Canada (UL File E341697); UL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E251761).
  • CE: European Union 2014/30/EC EMC Directive, compliant with EN 61326-1 and EN 61131-2.
  • C-Tick: Compliant with AS/NZS CISPR 11 for Industrial Emissions.
  • Ex / ATEX / UKCA: European Union Directive 2014/34/EU and UK SI 2016:1107; Ex ec IIC T4 Gc (ATEX Cert: 11 ATEX 7928686X, UKCA Cert: UL22UKEX2512X).
  • IECEx: Compliant with IEC 60079-0 and IEC 60079-7; II 3G Ex ec IIC T4 Gc (IECEx Cert: IECEx UL 15.0032X).
  • KC: Korean Registration of Broadcasting and Communications Equipment.
  • Functional Safety: TÜV Certified, capable of SIL 2 according to EN 62061, IEC 61508, and EN 61326-3-1.

FAQ

What is the channel capacity of the module?

The device features 8 digital output channels rated for 0.5 A per channel at an operating voltage range of 18 to 32V DC.

Which base unit and termination assemblies are required for installation?

The device mounts into the 1715-A3IO module base unit and connects via either the 1715-TASOB8DE simplex or 1715-TADOB8DE duplex termination assembly.

What functional safety level is supported by the unit?

The device is TÜV certified for Functional Safety and is capable of SIL 2 applications according to IEC 61508, EN 62061, and EN 61326-3-1 when used with specified firmware revisions.

What are the storage and operating temperature ratings for the device?

The operating temperature range is -25 degC to +60 degC, while the nonoperating storage temperature range is -40 degC to +85 degC.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1715-OB8DE 1715 Redundant I/O Digital Output Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Selecting Pneumatic Valve Actuation and Safe States

A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.

Designing Current Shunt Measurements That Stay Accurate

A practical guide to current-shunt measurement covering resistor sizing, high-side and low-side placement, Kelvin sensing, error budgets, thermal effects, protection and commissioning tests.

Engineering Logix Produced and Consumed Tags

A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic