Allen-Bradley

Allen-Bradley 1756-IA16 ControlLogix Discrete AC Input Module

SKU 1756-IA16

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-IA16

  • Country of origin:United States

  • Product Type: AC Input Modules

  • Payment: T/T, Western Union

  • Weight: 280g

  • Dimensions: 14.5 x 11.8 x 3.2 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Allen-Bradley 1756-IA16 is a high-performance ControlLogix discrete AC input module designed for industrial automation and control environments. Engineered to interface seamlessly with 120V AC switches, auxiliary contacts, and other discrete signaling devices, this module provides reliable signal conversion for complex automation architectures.

Operating as an integral component of the Rockwell Automation ControlLogix platform, the 1756-IA16 utilizes advanced Producer-Consumer technology. This capability enables input data and diagnostic information to be efficiently shared across multiple controllers over the backplane or network infrastructure, minimizing redundant wiring and maximizing system responsiveness.

Features

  • 16 discrete AC input channels grouped in 8 points per group for flexible wiring configurations
  • 120V AC nominal voltage category with an operating voltage range of 74 to 132V AC (47 to 63Hz)
  • Individual front-panel channel status LEDs for immediate visual verification of active and inactive inputs
  • User-selectable input filter times (1ms or 2ms for OFF to ON; 9ms or 18ms for ON to OFF) to suppress electrical noise
  • Robust Producer-Consumer architecture for high-speed, multi-controller data sharing across the ControlLogix backplane
  • Standard modular design that mounts directly into any ControlLogix chassis slot

Applications

  • Monitoring status signals from limit switches, pushbuttons, and selector switches in automated manufacturing lines
  • Interfacing auxiliary contacts from motor starters, contactors, and control relays
  • Discrete signal acquisition in packaging machinery, material handling systems, and assembly cells
  • Plant floor automation requiring reliable AC voltage sensing and noise immunity

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Exact Model 1756-IA16
Product Type ControlLogix Discrete AC Input Module
Inputs / Outputs 16 inputs (8 points per group)
Voltage Category 120V AC (50/60Hz)
Operating Voltage Range 74 to 132V AC (47 to 63Hz)
On-State Current (Min) 5mA @ 74V AC
On-State Current (Max) 13mA @ 132V AC
Off-State Voltage (Max) 20V AC
Off-State Current (Max) 2.5mA
Backplane Power Draw 100mA @ 5.1V DC; 2mA @ 24V DC (0.58W total)
Power Dissipation (Max) 5.8W @ 140 degF (60 degC)
Thermal Dissipation 18.41 BTU/hr
Compatible Removable Terminal Block (RTB) 1756-TBNH (Screw-clamp) or 1756-TBSH (Spring-clamp)
Country of Origin United States

Connections / Interfaces

Field-side wiring connects to the 1756-IA16 module via a separately ordered Removable Terminal Block (RTB) that plugs directly into the front of the unit. Compatible terminal blocks include the 20-position 1756-TBNH NEMA screw-clamp block or the 1756-TBSH spring-clamp terminal block. For extended wiring requirements, compatible interface modules (IFMs) and pre-wired cables can be utilized to streamline cabinet installation.

Installation Guidelines

The 1756-IA16 module mounts into any available slot within a standard Allen-Bradley ControlLogix chassis. Ensure power is removed from the chassis backplane and field wiring before installing or removing the module. Secure the module firmly using the top and bottom latching mechanisms. Verify that the correct RTB is selected and wired in accordance with local electrical codes and the manufacturer's installation drawings.

FAQ

What is the nominal input voltage for the Allen-Bradley 1756-IA16?

The 1756-IA16 is designed for a nominal 120V AC (50/60Hz) voltage category, with an operating range of 74 to 132V AC.

How many input channels does the 1756-IA16 module feature?

This module features 16 discrete input channels configured in two groups of 8 points per group.

Are removable terminal blocks included with the module?

No. Removable terminal blocks such as the 1756-TBNH or 1756-TBSH must be ordered separately to interface field wiring.

Which chassis are compatible with the 1756-IA16?

The module is designed to mount in any slot of a standard Allen-Bradley ControlLogix chassis backplane.

What programming software is required to configure this module?

The module is configured and integrated using RSLogix 5000 programming software or Studio 5000 Logix Designer.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1756-IA16 ControlLogix Discrete AC Input Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 14 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.