Allen-Bradley

Allen-Bradley 1761-L16BWB MicroLogix 1000 Programmable Controller

SKU 1761-L16BWB

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 1761-L16BWB

  • Country of origin:United States

  • Product Type: Programmable Controllers

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 230g

  • Dimensions: 120 mm x 40 mm x 80 mm (L x D x H)

  • Shipping port: Xiamen

  • Warranty: 12 months

The 1761-L16BWB is a compact programmable controller belonging to the MicroLogix 1000 product line. This electronic processor functions as a localized control block designed to modernize hardwired control logic systems within machine control configurations, localized factory automation setups, and designated process loops. Powered by an external 24V DC utility framework, the module maintains direct discrete tracking through integrated digital channels, executing instruction words via internal memory logic blocks.

To enable technical updates, diagnostic tracing, and commissioning loops, the 1761-L16BWB features an RS232 serial communication interface supporting the native DF1 protocol format. This dedicated connection port allows cross-system link setups to Human Machine Interfaces (HMI), Supervisory Control and Data Acquisition (SCADA) packages, and peripheral hardware converters. The controller can also adapt to external multi-node DH485 networks using a separate advanced interface converter or execute adjustments through a physical hand-held setup interface.

Features

  • Built-in 16-point integrated I/O configuration optimizing local physical space.
  • Integrated communication channel backing native serial point-to-point interface.
  • Dual sinking and sourcing wiring options for versatile sensor configuration.
  • Internal EEPROM storage framework ensuring reliable parameter preservation without battery dependencies.

Applications

  • Machinery manufacturing and localized operational line sequencing.
  • Factory floor process automation nodes.
  • Water, wastewater treatment, and HVAC equipment control loops.

Ordering Information

Catalog Number Series / Revision Details
1761-L16BWB Ser A 1761-L16BWB/A, Series A, Rev A
1761-L16BWB Ser B 1761-L16BWB/B, Series B, Rev B
1761-L16BWB Ser C 1761-L16BWB/C, Series C, Rev C
1761-L16BWB Ser D 1761-L16BWB/D, Series D, Rev D
1761-L16BWB Ser E 1761-L16BWB/E, Series E, Rev E

Technical Specifications

Parameter Specification
Manufacturer Allen Bradley
Product Type Programmable Logic Controller (PLC)
Product Line MicroLogix 1000
Part Number 1761-L16BWB
UPC 662468554497
I/O Count 16 points
Power Supply 20.4-26.4V dc
Input Power 5W
Inrush Current 30A for 4 ms
No. of Inputs Ten (10); Sinking / Sourcing
Input Voltage Type 14 - 30V dc
Input Type 24V dc
Output Type Six (6); Relay
Digital Outputs 6 Contact Outputs
Memory Size and Type 1 K EEPROM
Memory Capacity Approx. 737 instruction words and 437 data words
Communication Port RS232
Protocol DF1
Safety Feature Master Control Relay
Operating Frequency 47-63 Hz
Minimum Power Cycles 50,000
Operating Shock 10 G
Non-Operating Shock 20 G
Weight 0.50 lbs (0.23 kg)

Installation Guidelines

  • Mount the controller securely in a horizontal orientation to ensure proper ventilation and thermal cooling across internal electronic elements.
  • Route all low-voltage signal wiring separately from high-voltage electrical lines to eliminate signal crossover or EMI/RFI noise distortion.
  • Establish a direct, low-impedance ground connection from the chassis earth terminal to the main system enclosure backplane.
  • Ensure power sourcing requirements match the specified 20.4-26.4V DC bounds before energizing input terminal rows.

FAQ

What is the total number of physical inputs and outputs on the device?

The device features a fixed layout containing ten 24V DC digital inputs and six mechanical relay contact outputs.

Which protocol is natively supported by the integrated RS232 port?

The serial interface natively supports point-to-point communication through the DF1 protocol format.

What type of internal memory storage does the controller utilize?

The controller utilizes a 1 KB integrated EEPROM block to preserve user instruction routines and system data words without active battery support.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1761-L16BWB MicroLogix 1000 Programmable Controller

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.