Product Description

Description

The Allen-Bradley 1762-IF4 is a compact analog input expansion module designed specifically for use with MicroLogix 1200 and MicroLogix 1400 programmable logic controller systems. This module provides four single-ended, individually configurable input channels capable of accepting either voltage or current signals. Engineered for demanding industrial environments, the 1762-IF4 processes analog signals with high precision using an advanced Sigma-Delta analog-to-digital converter, helping to ensure reliable data acquisition for temperature, pressure, flow, and level monitoring applications.

The module communicates seamlessly across the MicroLogix expansion I/O bus without requiring a separate power supply, streamlining system architecture and reducing overall panel footprint. Configuration flexibility allows each channel to be independently set for voltage or current inputs, supporting both raw/proportional data formats and scaled-for-PID algorithms. Built-in diagnostic features continuously monitor for overrange, underrange, and open-circuit conditions, reporting faults directly to the controller for rapid troubleshooting and minimized downtime.

Features

  • Four configurable analog input channels supporting voltage and current signals
  • Compatible with Allen-Bradley MicroLogix 1200 and MicroLogix 1400 programmable controllers
  • Sigma-Delta A/D converter architecture for high-resolution measurement accuracy
  • Independent channel configuration for voltage (-10V to +10V, 0 to 10V) or current (4-20mA, 0-20mA) ranges
  • Real-time channel diagnostics with bit-level error reporting for open-circuit, overrange, and underrange conditions
  • Selectable data formats including raw/proportional and scaled-for-PID
  • Compact DIN rail or panel mounting design matching the 1762 expansion I/O form factor

Applications

  • Process control systems requiring analog sensor integration
  • Temperature monitoring via thermocouples or RTD transmitters with analog outputs
  • Flow, pressure, and level data acquisition in water treatment and manufacturing
  • OEM machinery automation utilizing MicroLogix controllers
  • Closed-loop PID control loops requiring precise feedback signals

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Type MicroLogix Analog Input Module
Catalog Number 1762-IF4
Number of Inputs 4 differential or single-ended (channels individually configurable)
A/D Converter Type Sigma-Delta
Input Voltage Range -10 to +10V DC, 0 to 10V DC
Input Current Range -20 to +20 mA, 4 to 20 mA
Input Impedance (Voltage Terminal) 200 kOhms
Input Impedance (Current Terminal) 275 Ohms
Bus Current Draw (5V DC) 30 mA
Bus Current Draw (24V DC) 40 mA
Common Mode Voltage Range +/-27V max
Common Mode Rejection >55 dB at 50 and 60 Hz
Non-Linearity +/-0.12% percent full scale
Operational Temperature -20 to 65 Celsius (-4 to 149 Fahrenheit)
Country of Origin United States

Connections / Interfaces

The 1762-IF4 module features removable terminal blocks with screw connections located on the front face, allowing secure wire termination without disturbing field wiring during module replacement. Built-in bus connectors on the side of the unit facilitate direct, cable-free connection to adjacent MicroLogix 1200 or 1400 controllers or other 1762 expansion modules.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What controllers are compatible with the Allen-Bradley 1762-IF4?
The 1762-IF4 is designed for use with Allen-Bradley MicroLogix 1200 and MicroLogix 1400 programmable logic controllers.
How many input channels does the 1762-IF4 provide?
The module provides four input channels that can be independently configured for either voltage or current signals.
Does the 1762-IF4 require an external power supply?
No, the module draws its necessary power directly from the controller or existing expansion bus via the internal bus connector.
What diagnostic features are included on this module?
The module includes built-in bit-level error reporting that notifies the controller of open-circuit conditions, as well as input overrange and underrange faults.
Reviews

1762-IF4

Stock & lead time on request

Call
1 of 1

Allen-Bradley 1762-IF4 MicroLogix Analog Input Module

Only 14 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1762-IF4

  • Country of origin:United States

  • Product Type: Analog Input Module

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 9.0 x 3.5 x 8.7 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Allen-Bradley 1762-IF4 is a compact analog input expansion module designed specifically for use with MicroLogix 1200 and MicroLogix 1400 programmable logic controller systems. This module provides four single-ended, individually configurable input channels capable of accepting either voltage or current signals. Engineered for demanding industrial environments, the 1762-IF4 processes analog signals with high precision using an advanced Sigma-Delta analog-to-digital converter, helping to ensure reliable data acquisition for temperature, pressure, flow, and level monitoring applications.

The module communicates seamlessly across the MicroLogix expansion I/O bus without requiring a separate power supply, streamlining system architecture and reducing overall panel footprint. Configuration flexibility allows each channel to be independently set for voltage or current inputs, supporting both raw/proportional data formats and scaled-for-PID algorithms. Built-in diagnostic features continuously monitor for overrange, underrange, and open-circuit conditions, reporting faults directly to the controller for rapid troubleshooting and minimized downtime.

Features

  • Four configurable analog input channels supporting voltage and current signals
  • Compatible with Allen-Bradley MicroLogix 1200 and MicroLogix 1400 programmable controllers
  • Sigma-Delta A/D converter architecture for high-resolution measurement accuracy
  • Independent channel configuration for voltage (-10V to +10V, 0 to 10V) or current (4-20mA, 0-20mA) ranges
  • Real-time channel diagnostics with bit-level error reporting for open-circuit, overrange, and underrange conditions
  • Selectable data formats including raw/proportional and scaled-for-PID
  • Compact DIN rail or panel mounting design matching the 1762 expansion I/O form factor

Applications

  • Process control systems requiring analog sensor integration
  • Temperature monitoring via thermocouples or RTD transmitters with analog outputs
  • Flow, pressure, and level data acquisition in water treatment and manufacturing
  • OEM machinery automation utilizing MicroLogix controllers
  • Closed-loop PID control loops requiring precise feedback signals

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Type MicroLogix Analog Input Module
Catalog Number 1762-IF4
Number of Inputs 4 differential or single-ended (channels individually configurable)
A/D Converter Type Sigma-Delta
Input Voltage Range -10 to +10V DC, 0 to 10V DC
Input Current Range -20 to +20 mA, 4 to 20 mA
Input Impedance (Voltage Terminal) 200 kOhms
Input Impedance (Current Terminal) 275 Ohms
Bus Current Draw (5V DC) 30 mA
Bus Current Draw (24V DC) 40 mA
Common Mode Voltage Range +/-27V max
Common Mode Rejection >55 dB at 50 and 60 Hz
Non-Linearity +/-0.12% percent full scale
Operational Temperature -20 to 65 Celsius (-4 to 149 Fahrenheit)
Country of Origin United States

Connections / Interfaces

The 1762-IF4 module features removable terminal blocks with screw connections located on the front face, allowing secure wire termination without disturbing field wiring during module replacement. Built-in bus connectors on the side of the unit facilitate direct, cable-free connection to adjacent MicroLogix 1200 or 1400 controllers or other 1762 expansion modules.

Loading product navigation…

What controllers are compatible with the Allen-Bradley 1762-IF4?

The 1762-IF4 is designed for use with Allen-Bradley MicroLogix 1200 and MicroLogix 1400 programmable logic controllers.

How many input channels does the 1762-IF4 provide?

The module provides four input channels that can be independently configured for either voltage or current signals.

Does the 1762-IF4 require an external power supply?

No, the module draws its necessary power directly from the controller or existing expansion bus via the internal bus connector.

What diagnostic features are included on this module?

The module includes built-in bit-level error reporting that notifies the controller of open-circuit conditions, as well as input overrange and underrange faults.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors in different ways. This comparison covers torque quality, speed range, reversal, braking, electrical noise, thermal behavior, feedback, and retrofit...

How Industrial Inverters Build AC From a DC Bus

Industrial inverters synthesize controllable AC from a DC bus through semiconductor switching and filtering. This guide explains H-bridges, PWM, harmonics, motor loads, protection, thermal limits,...

Robot Force Control: From Contact Detection to Stable Process

Force control lets a robot adapt to contact instead of following position alone. This guide compares sensing approaches, control modes, process limits, safety boundaries, commissioning tests, and...

When Sensor-Level Logic Helps—and When It Hides Risk

Configurable sensors can perform window, latch, delay, and Boolean decisions before data reaches a PLC. The benefit is faster local behavior; the risk is hidden logic, weak diagnostics, and...