Allen-Bradley

Allen-Bradley 1762-IF4 MicroLogix Analog Input Module

SKU 1762-IF4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 1762-IF4

  • Country of origin:United States

  • Product Type: Analog Input Module

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 9.0 x 3.5 x 8.7 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Allen-Bradley 1762-IF4 is an expansion analog input module designed specifically for the MicroLogix 1200 and MicroLogix 1400 programmable logic controller (PLC) systems. This compact unit interfaces directly with process sensors to convert real-world analog signals into digital values utilized by the controller's user program. It plays a critical role in continuous process control loops, acquiring precise voltage or current measurements from transmitters, transducers, and industrial instrumentation.

Featuring four single-ended input channels, the 1762-IF4 utilizes a high-resolution Sigma-Delta analog-to-digital converter to deliver reliable data conversion. The module supports selectable input types including voltage (-10V to +10V, 0 to 5V, 0 to 10V) and current (4 to 20mA, 0 to 20mA). Data is accessible to the processor as raw/proportional data or scaled-for-PID data formats, enabling seamless integration into temperature, pressure, level, and flow control loops.

Features

  • Four single-ended input channels configurable independently for voltage or current signals
  • Advanced Sigma-Delta A/D converter architecture for enhanced signal stability and noise rejection
  • Selectable data formats including raw/proportional data and engineering units scaled for PID algorithms
  • Comprehensive channel diagnostics with bit-reporting for open-circuit, over-range, and under-range conditions
  • Direct DIN rail or panel mounting for flexible physical installation within control enclosures
  • Compact 1762 expansion form factor optimizing panel space alongside MicroLogix base controllers

Applications

  • Monitoring process variables such as tank levels, line pressures, and flow rates via 4-20mA transmitters
  • Reading analog temperature signals from signal conditioners in thermal regulation processes
  • Providing real-time feedback variables for closed-loop PID control loops within OEM machinery
  • Acquiring diagnostic signal data to detect sensor wire breaks or out-of-range field conditions

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Type Analog Input Module
Series MicroLogix (1762)
Number of Inputs 4 single-ended channels
Input Ranges (Voltage) -10 to +10 VDC, 0 to 5 VDC, 0 to 10 VDC
Input Ranges (Current) 4 to 20 mA, 0 to 20 mA
A/D Converter Type Sigma-Delta
Resolution 12 bits (plus sign)
Input Impedance (Voltage Terminal) 200 kOhm
Input Impedance (Current Terminal) 275 kOhm
Bus Current Draw (5 VDC) 50 mA
Bus Current Draw (24 VDC) 35 mA
Operating Temperature -20 to 65 degC (-4 to 149 degF)
Enclosure Type Open style
Country of Origin United States

Compliance and Certifications

    Standard industrial agency certifications including c-UL-us, CE, and C-Tick for compliant global deployment.

FAQ

Which controllers are compatible with the Allen-Bradley 1762-IF4?

The 1762-IF4 module is designed for use with Allen-Bradley MicroLogix 1200 and MicroLogix 1400 programmable logic controllers.

How many input channels does the 1762-IF4 provide?

The module features 4 single-ended analog input channels, which can be individually configured for current or voltage signals.

What power supplies are required for the 1762-IF4?

The module draws internal power from the controller backplane, requiring 50 mA from the 5 VDC bus and 35 mA from the 24 VDC bus.

Does the 1762-IF4 support open-circuit detection?

Yes, the module includes hardware diagnostics that report open-circuit, over-range, and under-range conditions via bit status flags in the controller data table.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 14 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.