Description

The Allen-Bradley 1769-IF4 is a 4-channel analog input module designed for CompactLogix and MicroLogix 1500 control systems. This module provides high-resolution conversion of differential analog signals into digital values for industrial automation applications. It supports both voltage and current input configurations, enabling direct interfacing with analog field instruments such as transmitters, sensors, and flow meters. The 1769-IF4 features advanced hardware filtering to attenuate electronic noise and transient disturbances, ensuring reliable data acquisition in challenging industrial environments.

Features

  • Four independently configurable differential input channels.
  • Selectable voltage and current signal configurations for broad field instrument compatibility.
  • High-resolution analog-to-digital conversion up to 14 bits unipolar or 14 bits plus sign bipolar.
  • Effective operational isolation between the backplane logic circuit and field-side inputs.
  • Built-in input filtering to minimize electrical noise and transient signal variations.
  • Removable terminal block allowing convenient wiring and module maintenance without disconnecting cables.

Applications

  • Flow rate, pressure, and thermal processing loop control.
  • Machine and process monitoring via factory sensor networks.
  • Water and wastewater treatment monitoring networks.
  • Integration of chemical injection and mixing control instrumentation.
  • SCADA remote telemetry unit configurations.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Model Number 1769-IF4
Product Line CompactLogix / Compact I/O
Module Type 4-Channel Analog Input Module
Number of Inputs 4 differential
Input Signal Range (Voltage) Plus / minus 10V, 0 to 10V, 0 to 5V, 1 to 5V
Input Signal Range (Current) 0 to 20 mA, 4 to 20 mA
Resolution 14 bits (Unipolar); 14 bits plus sign (Bipolar)
Bus Current Draw (5V DC) 120 mA
Bus Current Draw (24V DC) 60 mA
Heat Dissipation 2.63 Watts
Isolation Voltage 500V AC or 710V DC for 1 minute (qualification test), inputs to bus
Rated Working Voltage 30V AC / 30V DC
Operating Temperature 0 to 60 degC (32 to 140 Fahrenheit)
Storage Temperature -40 to 85 degC (-40 to 185 Fahrenheit)
Relative Humidity 5% to 95% noncondensing
Vibration (Operating) 5g at 10 to 500 Hz
Dimensions (HxWxD) 118 x 35 x 87 mm (4.65 x 1.38 x 3.43 inches)
Height with Mounting Tabs 138 mm (5.43 inches)
Country of Origin Malaysia

 

Installation Guidelines

  • Module Placement: Mount the module onto a standard DIN rail or directly to a panel using integrated mounting tabs. Maintain a secure connection with adjacent Compact I/O modules via the built-in locking mechanism.
  • Power Supply Constraints: Ensure the configuration complies with distance ratings and backplane current limits. The module draws 120 mA at 5V DC and 60 mA at 24V DC from the system backplane power rail.
  • Shielding and Grounding: Use high-quality twisted-pair shielded cable for all analog signal paths. Connect the cable shield to a clean ground point at the controller end only to mitigate EMI/RFI issues.
  • Wiring Separation: Route low-voltage analog signal wires through dedicated conduits separated from high-voltage motor power lines and AC control wiring.

FAQ

How many input channels are available on the module?

The module features four independently configurable differential analog input channels.

What are the backplane power requirements for the device?

The device has a maximum current draw of 120 mA at 5V DC and 60 mA at 24V DC from the backplane.

What signal ranges are supported by the analog inputs?

The inputs support voltage ranges of plus / minus 10V, 0 to 10V, 0 to 5V, and 1 to 5V, as well as current ranges of 0 to 20 mA and 4 to 20 mA.

What is the recommended nonoperating storage temperature range?

The recommended storage temperature range for the module is from -40 degC to +85 degC.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1769-IF4 CompactLogix Analog Input Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Malaysia
Power source
DC Power

Technical knowledge

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.