The Allen-Bradley 1756-L55M12 is a ControlLogix 5555 processor module designed for high-performance industrial control applications. The 1756-L55M12 controller provides 750 Kbytes of user memory for data and logic programs, along with 208 Kbytes of dedicated I/O memory, operating without nonvolatile memory storage. The unit has an open-style enclosure rating and supports various communication networks across the ControlLogix platform, including ControlNet, EtherNet/IP, DH+, DeviceNet, and Universal Remote I/O networks. Multiple 1756-L55 controllers can be integrated into a redundant controller system configured within a ControlNet network.
Features
750 Kbytes user memory for data and logic
208 Kbytes dedicated I/O memory
Fast program scan time of 0.08 milliseconds
Supports up to 128,000 total I/O points
Supports up to 4,000 analog inputs and 2,000 analog outputs
Multi-protocol communication support across EtherNet/IP, ControlNet, DeviceNet, DH+, and Universal Remote I/O
Redundancy capability over ControlNet networks
Compatible with serial cables 1756-CP3 or 1747-CP3
Applications
Industrial PLC and DCS control systems
High-speed discrete logic processing
Multi-axis and complex analog process control
Redundancy systems via ControlNet networks
Distributed plant automation systems
Technical Specifications
Parameter
Specification
Manufacturer
Allen-Bradley
Product Line
ControlLogix
Category
PLCs / Processor Module
Part Number
1756-L55M12
User Memory (Data and Logic)
750 Kbytes
I/O Memory
208 Kbytes
Maximum I/O Capacity
128,000
Maximum Analog Inputs
4,000
Maximum Analog Outputs
2,000
Program Scan Time
0.08 ms
Backplane Current (5.1V DC)
1.23 A
Backplane Current (24V DC)
0.014 A (14 mA)
Power Dissipation
5.6 W
Thermal Dissipation
19.1 BTU/hr
Continuous Isolation Voltage
30V (Basic Insulation Type)
Dielectric Withstand Voltage
707V DC for 60 s
Conducted RF Immunity
10V rms with 1 kHz sine-wave 80% AM (150 kHz to 80 MHz)
Battery Type
1756-BA1 or 1756-BATM (1756-BA1 weight: 0.59 g)
Serial Cable Compatibility
1756-CP3 or 1747-CP3
Communication Wiring Category
2 (on communication ports)
Enclosure Type
Open Style
Operating Temperature
0 to 60 degC (32 to 140 F)
Storage Temperature
-40 to 85 degC
Relative Humidity
5% to 95% (noncondensing)
Operating Shock
30 g
Non-Operating Shock
50 g
Vibration
2 g at 10 to 500 Hz
Weight
0.81 lbs (0.37 kg / 12.5 oz)
UPC
10612598286628
Installation Guidelines
Ensure power to the ControlLogix chassis is disconnected prior to installing or removing the module.
Mount the unit into any available slot of a 1756 ControlLogix chassis.
Maintain adequate panel ventilation to keep ambient temperatures within 0 to 60 degC during operation.
Use 1756-CP3 or 1747-CP3 serial cables for direct serial interface connectivity.
Maintain proper ground connection on the chassis backplane to mitigate EMI/RFI interference.
Install a fresh 1756-BA1 or 1756-BATM lithium battery to retain volatile memory when the module is powered down.
FAQ
What battery types are used with this processor module to preserve memory?
The module uses either a 1756-BA1 or 1756-BATM lithium battery to maintain volatile memory when main system power is off.
What is the maximum I/O capacity supported by the device?
The processor supports up to 128,000 total I/O points, including up to 4,000 analog inputs and 2,000 analog outputs.
Which programming cables are compatible with the controller serial port?
The serial communication port is compatible with either the 1756-CP3 or 1747-CP3 programming cables.
What is the operating temperature range for the device?
The operating temperature range is from 0 degC to 60 degC (32 F to 140 F).
A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.
A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.
A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.
A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.
Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...