1 of 3

Allen-Bradley 1783-ETAP Stratix 2000 EtherNet/IP Tap

Allen-Bradley 1783-ETAP Stratix 2000 EtherNet/IP Tap

Only 8 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1783-ETAP

  • Country of origin:United States

  • Product Type: EtherNet IP Tap Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 15.5cm x 14cm x 10.7cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The 1783-ETAP is a three-port discrete physical layer networking component featuring Embedded Switch Technology to integrate non-switched industrial automation devices directly into linear or Device Level Ring (DLR) network topologies. It provides raw physical layer packet steering and conversion over three copper Ethernet ports, eliminating the need for dedicated multi-port managed switches in basic control zones. The device establishes direct deterministic node aggregation over EtherNet/IP infrastructures to interconnect remote logic chassis, motor control centers, or human-machine interfaces. Powered by a regulated 24 VDC circuit, it features solid-state basic electrical insulation from network-to-power and network-to-network pathways to preserve operational data integrity in high-interference automated manufacturing environments.

Features

  • Device Level Ring Integration: Enables standard point-to-point hardware terminal nodes to participate directly within single-fault tolerant DLR automation rings.
  • Three-Port Copper Grid: Equipped with three independent RJ45 copper ports to route concurrent field signals.
  • Rigid Signal Isolation: Implements continuous basic type insulation to guard inner control logic against communication channel spikes.
  • Low Thermal Footprint: Operates efficiently with a maximum power consumption rating of 3 W, reducing internal enclosure heat generation.
  • Industrial Temperature Code: Rated with North American and IEC T5 temperature codes for stable execution under restricted environmental parameters.
  • Compact Open Housing: Designed with a space-saving, open-style profile to optimize spatial footprints inside main bay control panels.

Applications

  • Linear and ring-configured Device Level Ring (DLR) segments in manufacturing zones.
  • Inter-chassis communication bridging for distributed industrial control networks.
  • Dedicated field-level extraction of diagnostic telemetry over discrete copper lines.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Model / Part Number 1783-ETAP
Technology Class Embedded Switch Technology
Device Description EtherNet/IP tap
Total Copper Ports 3 copper ports
Tap Type Copper
Maximum Current Consumption 125 mA @ 24V DC
DC Power Supply Input Rating 24V DC (20.4 to 27.6V DC) Class 2 / SELV
Continuous Isolation Voltage 30V (continuous), basic insulation type
Isolation Boundary Mapping Network channels to power, and network channels to network channels
Dielectric Type Testing Tested at 1250V AC for 60 s
Maximum Power Consumption 3 W
Power Dissipation 3 W
Enclosure Type Rating None (open-style)
North American Temp Code T5
IEC Temp Code T5
Power Port Wiring Category Category 1
Communication Port Wiring Category Category 2
Shipping Weight 2 Kg

Connections/Interfaces

Interface Type Terminal Specification / Description
Ethernet Connections RJ45 connector compliant with IEC 60603-7
Ethernet Media Requirement 2-pair or 4-pair Category 5e minimum cable according to TIA 568-B.1, or Category 5 cable according to ISO/IEC 24702
DC Power Connection (Single Wire) One 0.33 to 3.3 mm2 (22 to 12 AWG) solid or stranded copper wire
DC Power Connection (Dual Wire) Two 0.33 to 1.3 mm2 (22 to 16 AWG) solid or stranded copper wires
DC Conductor Insulation Spec Rated at 75 degC (167 degF) or greater, 1.2 mm (3/64 in.) maximum insulation thickness
Terminal Screw Torque 0.6 to 0.8 N m (5 to 7 lb in) on power connectors

Installation Guidelines

  • Conductor Routing Strategy: Use the designated conductor category rankings (Category 1 for power ports, Category 2 for communication ports) to isolate and plan independent internal cable tray routing paths, minimizing electromagnetic crosstalk.
  • Power Terminal Torque Bounds: Fasten terminal connection screws strictly within the 0.6 to 0.8 N m window to avoid fracturing copper wire strands or stripping terminal block threads.
  • Enclosure Environmental Shielding: Because this unit features an open-style enclosure rating, it must be mounted inside a secondary industrial enclosure that provides appropriate environmental protection against dust, humidity, and atmospheric contaminants.
  • Power Supply Restrictions: Power lines must derive exclusively from a certified 24 VDC Class 2 or Safety Extra-Low Voltage (SELV) rated power supply to prevent overvoltage breakdown.

FAQ

Q: What is the minimum cable specification required to establish network connections on this device?

A: Communication interfaces require a minimum of 2-pair or 4-pair Category 5e cabling conforming to TIA 568-B.1, or standard Category 5 cabling conforming to ISO/IEC 24702.

Q: Can two independent wires be landed into a single terminal point on the DC power block?

A: Yes, the power terminal block can accept two solid or stranded copper wires simultaneously, provided their individual cross-sectional sizes fall between 0.33 and 1.3 mm2 (22 to 16 AWG).

Q: What isolation metrics are verified between the internal communication channels?

A: The tap is factory type-tested at 1250V AC for 60 seconds, maintaining a continuous 30V basic insulation barrier between network channels and power, as well as between separate network channels.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Networking standards
IEEE 802.3
Power source
DC Power

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...