The 1794-IE12 is a high-density analog input module engineered to function within the FLEX I/O distributed hardware platform. This modular component provides twelve single-ended, non-isolated input channels designed to convert analog current or voltage signals from industrial transmitters into digital data for processing. By deploying this module adjacent to machinery on a local DIN rail, industrial facilities can significantly reduce field wiring runs by transmitting data back to a central processor via an appropriate network adapter over EtherNet/IP, ControlNet, or DeviceNet.
Operating over selectable ranges including 4 to 20 mA and 0 to 10V DC, the unit incorporates successive-approximation analog-to-digital converters to ensure precise measurement tracking. The 1794-IE12 plugs directly into a compatible terminal base unit, which manages the field-side wiring and provides the internal backplane connection. This layout is standard in continuous processing applications, water treatment automation, HVAC infrastructure control, and complex power generation monitoring where multi-channel instrumentation density is critical.
| Parameter | Specification |
|---|---|
| Manufacturer | Rockwell Automation / Allen-Bradley |
| Brand | FLEX I/O |
| Part Number | 1794-IE12 |
| Module Type | High-Density Analog Input Module |
| Number of Inputs | 12 Channels, Single-Ended, Non-Isolated |
| Input Signal Ranges | 4 to 20 mA, 0 to 20 mA, +/-10V DC, 0 to 10V DC |
| Resolution | 12-bit unipolar, 11-bit plus sign bipolar |
| Input Impedance (Voltage) | 100 kilohms minimum |
| Input Impedance (Current) | 238 ohms nominal |
| FlexBus Current Draw | 80 mA at 5V DC |
| External DC Power Voltage | 24V DC nominal |
| External DC Power Range | 10V DC to 31.2V DC |
| Operating Temperature | 0 to 55 degC |
| Storage Temperature | -40 to 85 degC |
| Relative Humidity | 5% to 95% non-condensing |
| Country of Origin | USA |
| Approximate Weight | 0.09 kg |
| Approximate Dimensions | 46 mm x 94 mm x 53 mm |
| Terminal Connection Block | Function |
|---|---|
| Input 0 to Input 11 | Single-Ended Positive Signal Input Nodes |
| Signal Return | Shared Analog Common Return Terminals |
| +V (External Power) | 24V DC External Operational Source Input |
| COM (External Power) | DC Power Return Reference Point |
Hook the top portion of the module structural housing into the upper ridge of standard 35 mm DIN mounting tracking. Pivot the lower portion of the enclosure downward firmly until the integrated locking clips engage onto the lower metal rail lip.
Align the guide keys located along the bottom edge of the hardware module with the receiving channels on the pre-wired terminal base unit. Slide the unit directly downward into the base structural framework until the retention latches snap shut.
Run shielded twisted-pair cables for all analog input lines. Ground the cable shield drain wires exclusively at the dedicated ground bus bars on the terminal base unit to avoid creating earth ground loops across the field environment.
Isolate all analog instrumentation signal conduits from high-power AC mains cabling, variable frequency drive motor leads, and heavy inductive switching circuits to mitigate electromotive field coupling and signal noise.
What types of signals can this module accept from field instruments?
It can be software-configured to accept either direct current ranges or standard analog voltage potential fields.
Does this module provide electrical isolation between individual input channels?
No, the twelve channels are single-ended and reference a shared internal common signal return path.
Can an engineer swap this unit while the rest of the FLEX I/O rail is active?
Yes, the module supports removal and insertion under power, allowing field service without interrupting communication to adjacent modules.
What happens if a field signal wire breaks or drops below 4 mA?
The processing register sets an under-range bit corresponding to that specific input channel to alert the logic controller of a fault.
Is an external power supply required to drive this module?
Yes, it requires an external 24V DC power feed wired directly through the terminal base to power the analog conversion circuitry.
Which terminal base structures are recommended for this component?
The unit operates with multi-terminal block bases including the 1794-TB3G or 1794-TB3GS configurations which handle the high-density signal count.
What is the digital conversion resolution of the incoming analog parameters?
The module utilizes a 12-bit analog-to-digital converter architecture to represent field values within the system registers.
Can this device measure negative voltage ranges from sensors?
Yes, it can be configured to process bipolar voltage inputs across a negative ten to positive ten volt range.
How is the specific signal range for a channel programmed?
The engineering ranges are defined by writing specific configuration words to the module output registers via the PLC software environment.
Does the module require field calibration before plant startup?
The module is calibrated during factory production, but zero and span configurations can be monitored and tweaked electronically through the host system.
Global Express Shipping
Returns & Warranty



Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Color pattern |
White
Greyish White
|
| Country of origin |
United States
|
| Power source |
DC Power
|