Allen-Bradley

Allen-Bradley 2711P-RP1X PanelView Plus 700 to 1500 Logic Module

SKU 2711P-RP1X

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 2711P-RP1X

  • Country of origin:United States

  • Product Type: Logic Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 160 mm x 130 mm x 35 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The 2711P-RP1X is a logic module family for Allen-Bradley PanelView Plus 700 to 1500 terminals. It attaches to the rear of the display module and provides the terminal processing, memory, communication, firmware, and operating-system functions.

The logic module includes 64 MB internal CompactFlash memory and 64 MB RAM. Its external connections include an Ethernet port, a serial port, two USB ports, and a CompactFlash card slot. Status indicators provide operating information for the installed terminal.

The official installation document uses 2711P-RP1x as the family designation. Individual module revisions are identified by their series suffix.

Features

  • Designed for PanelView Plus 700 to 1500 terminals
  • 64 MB internal CompactFlash memory
  • 64 MB RAM
  • Ethernet communication port
  • Serial communication port
  • Two USB ports
  • CompactFlash card slot
  • Integrated status indicators
  • Replaceable RAM module
  • Replaceable internal CompactFlash card
  • Rear-mounted connection to the display module
  • Field-installable module construction

Applications

  • PanelView Plus terminal logic-module replacement
  • Industrial machine operator interfaces
  • Manufacturing HMI stations
  • Production-line visualization terminals
  • Process equipment operator panels
  • Existing PanelView Plus system maintenance

Technical Specifications

General

Parameter Specification
Manufacturer Allen-Bradley
Model Family 2711P-RP1x
Product Type Logic Module
Product Series PanelView Plus
Compatible Terminal Range PanelView Plus 700 to 1500
Installation Location Rear of the display module

Memory

Parameter Specification
Internal CompactFlash 64 MB
RAM 64 MB
RAM Type SODIMM RAM
Firmware Storage Internal CompactFlash
Operating System Storage Internal CompactFlash

Module Series

Series Module Designation
Series A 2711P-RP1x/A
Series B 2711P-RP1x/B
Series C 2711P-RP1x/C
Series D 2711P-RP1x/D
Series E 2711P-RP1x/E
Series F 2711P-RP1xx/F
Series G 2711P-RP1xxx/G

Connections/Interfaces

Interface Function
Ethernet Port Ethernet network connection
Serial Port Serial communication connection
USB Ports Two USB device connections
CompactFlash Card Slot External CompactFlash card access
Internal CompactFlash Interface Firmware and operating-system storage
Display Module Connectors Connection between the logic module and display module
Status Indicators Module operating-status indication

Installation Guidelines

  • Disconnect all power from the terminal before installing or replacing the module.
  • Disconnect all power and communication cables before module removal.
  • Wear a properly grounded ESD wristband.
  • Work in a static-free environment.
  • Avoid touching exposed electronic components.
  • Install the RAM and internal CompactFlash before attaching the logic module when supplied separately.
  • Place the display module face-down on a clean, flat, stable surface.
  • Align the two logic-module connectors with the display-module connectors.
  • Press the logic module down until it is firmly seated.
  • Tighten the six captive screws to 0.58 N m (5 to 7 lb in).
  • Remove any attached communication module before replacing the logic module.
  • Reinstall the communication module after the logic module is securely mounted.
  • Verify the logic-module series before transferring RAM or internal CompactFlash components.

FAQ

Which terminals support the module?

The module family is designed for PanelView Plus 700 to 1500 terminals.

How much memory does the module include?

The module family includes 64 MB internal CompactFlash and 64 MB RAM.

Which communication interfaces are provided?

The module includes one Ethernet port, one serial port, and two USB ports.

Can the internal memory be replaced?

Yes. The RAM and internal CompactFlash can be installed or replaced separately.

What mounting torque is required?

Tighten the six captive screws to 0.58 N m, equivalent to 5 to 7 lb in.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.