Allen-Bradley

Allen-Bradley 2711P-RP1X PanelView Plus 700 to 1500 Logic Module

SKU 2711P-RP1X

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 2711P-RP1X

  • Country of origin:United States

  • Product Type: Logic Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 160 mm x 130 mm x 35 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The 2711P-RP1X is a logic module family for Allen-Bradley PanelView Plus 700 to 1500 terminals. It attaches to the rear of the display module and provides the terminal processing, memory, communication, firmware, and operating-system functions.

The logic module includes 64 MB internal CompactFlash memory and 64 MB RAM. Its external connections include an Ethernet port, a serial port, two USB ports, and a CompactFlash card slot. Status indicators provide operating information for the installed terminal.

The official installation document uses 2711P-RP1x as the family designation. Individual module revisions are identified by their series suffix.

Features

  • Designed for PanelView Plus 700 to 1500 terminals
  • 64 MB internal CompactFlash memory
  • 64 MB RAM
  • Ethernet communication port
  • Serial communication port
  • Two USB ports
  • CompactFlash card slot
  • Integrated status indicators
  • Replaceable RAM module
  • Replaceable internal CompactFlash card
  • Rear-mounted connection to the display module
  • Field-installable module construction

Applications

  • PanelView Plus terminal logic-module replacement
  • Industrial machine operator interfaces
  • Manufacturing HMI stations
  • Production-line visualization terminals
  • Process equipment operator panels
  • Existing PanelView Plus system maintenance

Technical Specifications

General

Parameter Specification
Manufacturer Allen-Bradley
Model Family 2711P-RP1x
Product Type Logic Module
Product Series PanelView Plus
Compatible Terminal Range PanelView Plus 700 to 1500
Installation Location Rear of the display module

Memory

Parameter Specification
Internal CompactFlash 64 MB
RAM 64 MB
RAM Type SODIMM RAM
Firmware Storage Internal CompactFlash
Operating System Storage Internal CompactFlash

Module Series

Series Module Designation
Series A 2711P-RP1x/A
Series B 2711P-RP1x/B
Series C 2711P-RP1x/C
Series D 2711P-RP1x/D
Series E 2711P-RP1x/E
Series F 2711P-RP1xx/F
Series G 2711P-RP1xxx/G

Connections/Interfaces

Interface Function
Ethernet Port Ethernet network connection
Serial Port Serial communication connection
USB Ports Two USB device connections
CompactFlash Card Slot External CompactFlash card access
Internal CompactFlash Interface Firmware and operating-system storage
Display Module Connectors Connection between the logic module and display module
Status Indicators Module operating-status indication

Installation Guidelines

  • Disconnect all power from the terminal before installing or replacing the module.
  • Disconnect all power and communication cables before module removal.
  • Wear a properly grounded ESD wristband.
  • Work in a static-free environment.
  • Avoid touching exposed electronic components.
  • Install the RAM and internal CompactFlash before attaching the logic module when supplied separately.
  • Place the display module face-down on a clean, flat, stable surface.
  • Align the two logic-module connectors with the display-module connectors.
  • Press the logic module down until it is firmly seated.
  • Tighten the six captive screws to 0.58 N m (5 to 7 lb in).
  • Remove any attached communication module before replacing the logic module.
  • Reinstall the communication module after the logic module is securely mounted.
  • Verify the logic-module series before transferring RAM or internal CompactFlash components.

FAQ

Which terminals support the module?

The module family is designed for PanelView Plus 700 to 1500 terminals.

How much memory does the module include?

The module family includes 64 MB internal CompactFlash and 64 MB RAM.

Which communication interfaces are provided?

The module includes one Ethernet port, one serial port, and two USB ports.

Can the internal memory be replaced?

Yes. The RAM and internal CompactFlash can be installed or replaced separately.

What mounting torque is required?

Tighten the six captive screws to 0.58 N m, equivalent to 5 to 7 lb in.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.