Allen-Bradley

Allen-Bradley 81007-465-51-R Voltage Sensing Board

SKU 81007-465-51-R

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 81007-465-51-R

  • Country of origin:United States

  • Product Type: Voltage Sensing Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 25.1cm x 19cm x 2.6cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Allen-Bradley 81007-465-51-R is an industrial VOLTAGE SENSING BOARD designed for precise electrical measurement and monitoring within automation infrastructures. This hardware component tracks alternating current and direct current voltage thresholds, translating measured electrical inputs into standard proportional analog output paths. Equipped with high-voltage galvanic isolation pathways, the 81007-465-51-R protects low-voltage central processing units and controller networks from high-energy field transients across heavy-duty processing operations.

Features

  • Dual-measurement capabilities supporting both alternating current and direct current input voltage sensing tasks on a single board assembly.
  • High structural galvanic isolation barrier built in to isolate field signals from sensitive downstream control systems.
  • Dual standard analog output formats configurable for long-distance signal loop integration without degradation.

Applications

  • High-voltage line tracking and main power feed monitoring in industrial distribution panels.
  • Dynamic voltage feedback inside large-scale motor control centers and drive systems.
  • Multi-rail power infrastructure inspection within manufacturing plant networks.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley
Model Number 81007-465-51-R
Product Type Voltage Sensing Board
AC Input Voltage Bounds 0 - 600 V AC
DC Input Voltage Bounds 0 - 1000 V DC
Isolation Voltage Rating 2500 V AC
Configurable Output Signals 0 - 10 V DC or 4 - 20 mA
Measurement Accuracy +/-1% full scale
Frequency Response Range 50/60 Hz
Country of Origin USA
Tariff Code 8537101190
Chassis Weight 3.45 kg
Operating Temperature Bounds -20 Celsius to +70 Celsius
Storage Temperature Bounds -40 Celsius to +85 Celsius
Humidity Tolerance Window 5 - 95% RH (non-condensing)

Installation Guidelines

  • Voltage Clearance: Ensure that target measurement wiring meets the appropriate insulation levels for the 600 VAC or 1000 VDC maximum operational boundaries before terminal coupling.
  • Grounding Execution: Secure low-impedance frame ground tracking to the primary control enclosure chassis to filter noise and preserve signal conversion accuracy.
  • Thermal Environment Management: Verify panel air circulation maintains surrounding air parameters within the specified -20 Celsius to +70 Celsius window during sustained operation under load.

FAQ

Does this device measure alternating current or direct current voltage?

The board features dual capability and is engineered to measure both AC voltage from 0 to 600 V and DC voltage from 0 to 1000 V.

What type of interface signals does the module output?

The device converts the tracked input parameters into standard analog outputs, providing either a 0 to 10 V DC voltage loop or a 4 to 20 mA current loop.

What level of electrical protection exists between the input and control circuits?

The device features a high isolation rating designed to withstand up to 2500 V AC, ensuring electrical safety for connected downstream processing equipment.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Red
Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.