Product Overview

The MVAJ105RA0802A (MVAJ105RA0802A) is a high-speed, hinged armature tripping relay belonging to the renowned MVAJ product range. This module acts as the critical interface between primary protective relays and circuit breaker trip coils in high-voltage substations and industrial power networks. Designed for absolute reliability, the MVAJ105RA0802A ensures that trip commands are executed with sub-millisecond precision and minimal contact bounce. By providing a rugged and flexible link in the protection chain, this relay prevents equipment damage and enhances the safety of power distribution systems under fault conditions.

Technical Configuration (Deep Dive)

The MVAJ range is engineered to accommodate a variety of complex tripping schemes through its versatile armature design and burden-selection capabilities.

  • High-Speed Operation: Utilizes a lightweight, high-performance hinged armature that ensures rapid contact closure, vital for minimizing the duration of electrical faults.

  • Selectable Burden: Features an external link connection that allows engineers to select between high and low burdens. The high-burden configuration provides superior immunity to wiring capacitance discharge, preventing nuisance tripping in extensive cabling networks.

  • Reset Logic: The RA0802A variant is typically configured with hand or electrical reset mechanisms (depending on internal wiring), providing clear visual indication of a trip event via a mechanical flag.

  • Immunity & Security: Built with internal filtering to ensure immunity to AC/DC interference and capacitive discharge from long pilot wires, making it ideal for large-scale utility grids.

Technical Specifications

Attribute Specification Details
Model MVAJ105RA0802A
Brand ALSTOM (GE Protection & Control)
Origin USA / UK
Relay Type Hinged Armature Tripping Relay
Reset Type Hand / Electrical Reset (RA Series)
Burden Selection High or Low (External Link)
Operating Temp -10 to 55 deg C
Storage Temp -25 to 70 deg C
Dimensions 22 x 182 x 127 mm
Weight 0.14 kg

Technical FAQs

Q1: How does the MVAJ105RA0802A prevent accidental tripping from stray signals?

A1: The relay can be configured in a high-burden mode, which requires a higher energy threshold to operate. This effectively filters out noise and capacitive discharges common in long-distance control wiring.

Q2: What is the significance of the "RA" code in the model number?

A2: The "RA" designation refers to the specific contact arrangement and reset logic. In this series, it signifies a relay designed for multi-contact tripping with specific reset capabilities for fault signaling.

Q3: Does the mechanical flag require manual intervention after a fault?

A3: Yes, for hand-reset models, the mechanical flag must be manually reset by an operator after the fault is cleared to acknowledge the trip event and restore the relay to its ready state.


Engineering & Installation Guide

  • Contact Burden Setting: During commissioning, verify the external link position. Use the "High Burden" setting if the relay is located at a significant distance from the protective device to negate the effects of cable capacitance.

  • Mounting Orientation: The MVAJ105RA0802A must be mounted vertically on a vibration-free panel. Any significant tilt can affect the gravitational balance of the hinged armature, potentially altering the operating speed or sensitivity.

  • Tripping Coil Compatibility: Ensure the breaker trip coil's current requirements do not exceed the relay’s contact rating. For multiple trip coils, verify that the parallel current remains within the 10 A (short-term) thermal limit of the relay contacts.

Engineering Advantages

The ALSTOM MVAJ105RA0802A is celebrated for its "set and forget" reliability. With its minimal contact bounce and high-speed response, it protects circuit breaker coils from prolonged energization. The module's design is compliant with the highest international protection standards, ensuring that it remains operational even after years of inactivity in a substation cabinet. Its compact footprint allows for high-density installation, enabling complex multi-contact tripping schemes to be housed in standard protection racks without excessive space requirements.


Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...