Manufacturer: BECKHOFF
Product No.: BK7000
Country of origin:Germany
Product Type: ControlNet Bus Coupler
Payment: T/T, Western Union
Weight: 170g
Shipping port: Xiamen
Warranty: 12 months
The BECKHOFF BK7000 is a ControlNet Bus Coupler designed to connect ControlNet networks with the modular electronic terminal blocks. Serving as a node in a distributed automation system, this coupler handles the data exchange between the higher-level ControlNet master and the connected Bus Terminals. It automatically detects connected Bus Terminals during the boot-up phase and establishes the local K-bus communication structure, mapping the peripheral signals into the internal process image.
Equipped with dual BNC female connectors and a programming port (NAP), the BK7000 integrates seamlessly into industrial communication architectures. It supports up to 64 Bus Terminals natively, with extension capabilities allowing connection to larger signal groupings. Power distribution is managed through integrated power contacts, supplying both the internal electronics and the field level efficiently while maintaining electrical isolation between the communication interface, field-side supply, and system levels.
| Parameter | Specification |
|---|---|
| Manufacturer | BECKHOFF |
| Exact Model | BK7000 |
| Product Type | ControlNet Bus Coupler |
| Number of Bus Terminals | 64 (expandable up to 255 with extension terminals) |
| Max. Fieldbus Data Size | 512 bytes input and 512 bytes output |
| Digital Peripheral Signals | 512 inputs / 512 outputs |
| Analog Peripheral Signals | 256 inputs / 256 outputs |
| Data Transfer Rates | 5 Mbaud |
| Bus Interface | 2 x BNC female connector + NAP |
| Power Supply | 24 V DC (-15 % / +20 %) |
| Input Current | 70 mA + (total K-bus current) / 4, 500 mA max. |
| Starting Current | 2.5 x continuous current |
| Recommended External Fuse | ≤ 10 A |
| K-Bus Current Supply | 1750 mA |
| Power Contacts | 24 V DC max. / 10 A max. |
| Electrical Isolation | 500 V (power contact / supply voltage / K-bus) |
| Configuration | Via KS2000 software |
| Operating Temperature | 0 to +55 degC |
| Storage Temperature | -25 to +85 degC |
| Relative Humidity | 95 %, no condensation |
| Vibration / Shock Resistance | Conforms to EN 60068-2-6 / EN 60068-2-27 |
| EMC Immunity / Emission | Conforms to EN 61000-6-2 / EN 61000-6-4 |
| Protection Class | IP 20 |
| Installation Position | Variable |
| Net Weight | Approx. 170 g |
| Approvals | CE, UL, Ex |
| Interface | Function |
|---|---|
| BNC Female Connector (In/Out) | ControlNet network medium connection |
| NAP (Network Access Port) | Diagnostic and programming connection |
| Power Contacts | Field supply distribution (24 V DC, 10 A max.) |
| K-Bus | Internal communication to connected Bus Terminals |