Description

Designed to integrate directly onto the right-hand side of compatible operator interfaces, the C9900-E545 provides supplementary physical operator control elements for CP6xxx and CP7xxx series Control Panels and Panel PCs. This hardware extension is engineered specifically for 15-inch displays configured without integrated keyboards, delivering structured control feedback in demanding industrial environments.

The layout incorporates 16 illuminated push-buttons alongside a dedicated safety element. Operator signals utilize a dual-transmission design: primary control transmission and signal lamp illumination route via CP-Link or USB interfaces, while a terminal strip allows secondary hardwiring of normally-open contacts for critical process operations. Customizable label inserts permit site-specific marking of individual buttons to align with plant system configurations.

Features

  • Compatible with right-side mounting on 15-inch CP6x02-00xx and CP7x02-00xx panels.
  • Equipped with 16 square push-buttons (30 x 30 mm) featuring integrated signal lamps.
  • Includes 1 standard-compliant emergency stop button for direct integration into safety circuits.
  • Dual-contact output design: signals transmit via digital interface (CP-Link or USB) and via secondary direct terminal-row connection.
  • Removable caps enable custom physical labeling of all push-buttons.

Applications

  • Human-Machine Interface (HMI) expansion for CNC and machine tool control.
  • Automotive assembly line operator stations.
  • Specialty machine manufacturing requiring localized tactile controls and emergency stop functions.

Technical Specifications

ParameterSpecification
Manufacturer BECKHOFF
Part Number / Model C9900-E545
Compatibility CP6xxx and CP7xxx series Control Panels / Panel PCs (15-inch display without keyboard)
Mounting Location Right-hand side of the host panel
Push-Buttons 16 x illuminated push-buttons (Siemens Signum square, 30 x 30 mm)
Emergency Stop Switch 1 x Siemens Signum emergency stop (directly wireable)
Signal Interface CP-Link or USB (for primary contacts and signal lamps)
Auxiliary Interface Terminal row (for hardwiring second normally-open contacts)
Shipping Weight 5 kg

Connections and Interfaces

Interface Type Function Assignment
USB / CP-Link Connection Primary normally-open (NO) contact transmission and signal lamp control power.
Internal Terminal Strip Direct connection points for secondary normally-open (NO) contacts.
Emergency Stop Terminals Dedicated dry contact points for direct safety circuit integration.

Installation Guidelines

  • Ensure all power is disconnected from the main Control Panel or Panel PC prior to mounting the extension.
  • Align the structural fastening points on the right flange of the 15-inch panel housing to secure the mechanical link.
  • Route the USB/CP-Link internal cables to the host motherboard connectors without pinching.
  • Observe regional safety standards when wiring the emergency stop switch to the main safety monitoring relay.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Which specific panels are compatible with the BECKHOFF C9900-E545?
The C9900-E545 is designed for mounting on the right-hand side of BECKHOFF CP6xxx and CP7xxx series Control Panels and Panel PCs with 15-inch displays that do not contain an integrated physical keyboard.
Can the emergency stop button be integrated into a safety PLC loop?
Yes, the emergency stop switch is designed to be directly wireable via independent terminals, allowing integration into standard safety relays or safety PLC architectures.
How are the 16 signal lamps powered and controlled?
The signal lamps are controlled and powered exclusively through the USB or CP-Link connection linked to the host system.
Reviews

C9900-E545

Stock & lead time on request

Call
1 of 1

BECKHOFF C9900-E545 Control Panel Accessories Push-Button Extension

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: C9900-E545

  • Country of origin:Germany

  • Product Type: Push-Button Extensions

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Dimensions: drawings with dimensions of the push-button e x tensions as AutoCAD DXF file

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed to integrate directly onto the right-hand side of compatible operator interfaces, the C9900-E545 provides supplementary physical operator control elements for CP6xxx and CP7xxx series Control Panels and Panel PCs. This hardware extension is engineered specifically for 15-inch displays configured without integrated keyboards, delivering structured control feedback in demanding industrial environments.

The layout incorporates 16 illuminated push-buttons alongside a dedicated safety element. Operator signals utilize a dual-transmission design: primary control transmission and signal lamp illumination route via CP-Link or USB interfaces, while a terminal strip allows secondary hardwiring of normally-open contacts for critical process operations. Customizable label inserts permit site-specific marking of individual buttons to align with plant system configurations.

Features

  • Compatible with right-side mounting on 15-inch CP6x02-00xx and CP7x02-00xx panels.
  • Equipped with 16 square push-buttons (30 x 30 mm) featuring integrated signal lamps.
  • Includes 1 standard-compliant emergency stop button for direct integration into safety circuits.
  • Dual-contact output design: signals transmit via digital interface (CP-Link or USB) and via secondary direct terminal-row connection.
  • Removable caps enable custom physical labeling of all push-buttons.

Applications

  • Human-Machine Interface (HMI) expansion for CNC and machine tool control.
  • Automotive assembly line operator stations.
  • Specialty machine manufacturing requiring localized tactile controls and emergency stop functions.

Technical Specifications

ParameterSpecification
Manufacturer BECKHOFF
Part Number / Model C9900-E545
Compatibility CP6xxx and CP7xxx series Control Panels / Panel PCs (15-inch display without keyboard)
Mounting Location Right-hand side of the host panel
Push-Buttons 16 x illuminated push-buttons (Siemens Signum square, 30 x 30 mm)
Emergency Stop Switch 1 x Siemens Signum emergency stop (directly wireable)
Signal Interface CP-Link or USB (for primary contacts and signal lamps)
Auxiliary Interface Terminal row (for hardwiring second normally-open contacts)
Shipping Weight 5 kg

Connections and Interfaces

Interface Type Function Assignment
USB / CP-Link Connection Primary normally-open (NO) contact transmission and signal lamp control power.
Internal Terminal Strip Direct connection points for secondary normally-open (NO) contacts.
Emergency Stop Terminals Dedicated dry contact points for direct safety circuit integration.

Installation Guidelines

  • Ensure all power is disconnected from the main Control Panel or Panel PC prior to mounting the extension.
  • Align the structural fastening points on the right flange of the 15-inch panel housing to secure the mechanical link.
  • Route the USB/CP-Link internal cables to the host motherboard connectors without pinching.
  • Observe regional safety standards when wiring the emergency stop switch to the main safety monitoring relay.

Which specific panels are compatible with the BECKHOFF C9900-E545?

The C9900-E545 is designed for mounting on the right-hand side of BECKHOFF CP6xxx and CP7xxx series Control Panels and Panel PCs with 15-inch displays that do not contain an integrated physical keyboard.

Can the emergency stop button be integrated into a safety PLC loop?

Yes, the emergency stop switch is designed to be directly wireable via independent terminals, allowing integration into standard safety relays or safety PLC architectures.

How are the 16 signal lamps powered and controlled?

The signal lamps are controlled and powered exclusively through the USB or CP-Link connection linked to the host system.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...