BECKHOFF

Beckhoff CP6511-0001-0080 CP65xx Series 12-inch Built-in Panel PC

SKU CP6511-0001-0080

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CP6511-0001-0080

  • Country of origin:Germany

  • Product Type: Built-in Panel PCs

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered to deliver high-reliability operator interface performance in challenging industrial environments, the Beckhoff CP6511-0001-0080 features a rugged 12-inch TFT display with an 800 x 600 pixel resolution. This built-in industrial panel PC integrates core computing capability directly behind the visualization interface, optimizing control cabinet footprint and simplifying Fieldbus communication integration.

Key Features

  • High-Resolution Display: 12-inch TFT active matrix screen supporting 800 x 600 pixel layouts for clear graphic visualization.
  • Industrial Grade Protection: Certified IP65 front-side seal protects internal electronic components from dust and high-pressure liquid ingress.
  • Fast Mounting Mechanics: Equipped with pull-out clamping levers designed for direct, secure installation without loose mounting hardware.
  • Durable Enclosure: Industrial enclosure designed for flush mounting in control cabinets and consoles, offering IP20 rear protection.

Applications

  • HMI terminal for material handling, manufacturing lines, and process control systems.
  • Central visualization nodes in automotive and chemical production plants.
  • Integrated control terminal for PLC systems and motion controllers.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model Number CP6511-0001-0080
Display Size 12-inch
Resolution 800 x 600 pixels
Front Protection Class IP65
Rear Protection Class IP20
Operating Temperature Range 0 to 55 degC
Country of Origin Germany
Shipping Weight (Calculated) 8.0 kg

Empirical Engineering Insights

Based on extensive field deployment logs of the Beckhoff CP65xx range, our engineering team has compiled critical optimization guidelines:

Alternative Models & Compatibility

The CP6511-0001-0080 is fully backward compatible with legacy CP6511 physical cutouts, allowing effortless drop-in replacements. Note that software dependencies on specific TwinCAT revisions may apply if utilizing specific on-board motherboard configurations.

Application Pitfalls & Engineering Notes

To prevent early aging of the display backlight array, ensure the active display screen timeout is configured correctly in the OS. Avoid mounting the unit directly above major heat sources like heavy-duty motor drives without active cooling baffles.

Commissioning & Wiring Tips

Use a dedicated, noise-isolated 24V DC power feed for the display unit. Ensure the mounting panel cutout edges are completely deburred to maintain the integrity of the front IP65 sealing gasket upon torque application.

Installation Guidelines

CRITICAL SAFETY WARNING

Before physical installation or electrical termination, ensure all main and control power circuits are completely de-energized and locked out. Verify that no residual voltages are present on the cabinet terminal blocks.

1

Prepare a precise control cabinet cutout matching the specific dimensional specifications of the 12-inch panel PC frame.

2

Carefully insert the panel PC through the cutout from the front side, ensuring the pre-installed sealing gasket sits flush and uniform against the exterior mounting surface.

3

Access the device from the rear and engage the integrated pull-out clamping levers to lock the unit securely into place against the cabinet wall.

4

Terminate power lines and interface cables, ensuring clean cable management and adequate strain relief.

FAQ

What is the IP protection rating of the CP6511-0001-0080?

The panel features an IP65 rated front side protection against dust and water jets when flush-mounted, and an IP20 rating on the rear chassis.

Does this model require loose brackets for installation?

No, this model features built-in pull-out clamping levers designed for fast installation directly into the cabinet cutout without the need for loose mounting components.

What is the recommended operating temperature range?

The panel is designed for industrial environments and operates reliably between ambient temperatures of 0 and 55 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.