BECKHOFF

Beckhoff CX1010-0020 CX1010 Basic CPU Module

SKU CX1010-0020

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX1010-0020

  • Country of origin:Germany

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 58 mm x 120 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Engineered for DIN rail mounting in industrial control environments, the Beckhoff CX1010-0020 serves as the central processing core of the CX1010 Embedded PC system. This module integrates an Intel Pentium MMX-compatible processor running at 500 MHz to execute deterministic control tasks and communication protocols. Designed without moving parts, it relies on passive convection cooling and solid-state Compact Flash storage to ensure long-term reliability in demanding automation architectures.

Key Features

  • Processing Core: Intel Pentium MMX-compatible processor clocked at 500 MHz for efficient execution of control logic.
  • Memory Architecture: Equipped with 256 MB DDR RAM (non-expandable) and a dedicated Compact Flash Type II slot (128 MB card included).
  • Integrated Connectivity: Features one RJ45 Ethernet port supporting 10/100 Mbit/s communication interfaces.
  • Modular Expansion: Utilizes a 16-bit ISA (PC/104) system bus for direct coupling with CX-series power supply and I/O modules.
  • Diagnostic LEDs: Dedicated physical indicators for power status, LAN speed, LAN activity, TwinCAT status, and flash memory access.

Industrial Applications

  • Factory automation and distributed machine control systems.
  • Process monitoring and data acquisition in manufacturing lines.
  • Building automation and infrastructure control networks.
  • Custom OEM machine building requiring compact, DIN-rail mounted control nodes.

Technical Specifications

Manufacturer Beckhoff
Model Number CX1010-0020
Processor Intel Pentium MMX compatible, 500 MHz (1 Core)
System Memory 256 MB DDR RAM (non-expandable)
Flash Memory Compact Flash Type II slot, 128 MB card included (expandable)
Network Interfaces 1 x RJ45 (10/100 Mbit/s)
System Bus Connection 16-bit ISA (PC/104)
I/O Connection Type Via CX1100 power supply module (supports E-bus, K-bus, K-bus/IP-Link)
Power Supply Input Via system bus (requires CX1100-xxxx power supply module)
Max. Power Consumption 8 W
Operating System Microsoft Windows Embedded Standard 2009
Control Software No TwinCAT pre-installed
Operating Temperature 0 to 50 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Dimensions (W x H x D) 58 mm x 120 mm x 91 mm
Net Weight 355 g
Shipping Weight 2.0 kg
Approvals CE, UL

Connections and Interfaces

Interface / Port Physical Type Functional Assignment
LAN Port RJ45 (8-pin) 10/100 Mbit/s Ethernet connection for host communication and programming
Compact Flash Slot CF Type II with ejector Solid-state storage for operating system, runtime, and user application data
System Bus Connection PC/104 (16-bit ISA) Internal data and power interface to adjacent CX1100 power supply modules

Empirical Engineering Insights

Alternative Models & Compatibility

The CX1010-0020 requires a matching CX1100-xxxx power supply module (such as the CX1100-0002 or CX1100-0003) to function, as it does not possess an integrated power supply unit. When replacing older CX1000 series modules, note that while the physical form factor is similar, the CX1010 utilizes a newer chipset architecture. Ensure your TwinCAT configuration is updated to target the correct CPU architecture.

Application Pitfalls & Engineering Notes

Because this module runs Windows Embedded Standard 2009, write-intensive applications can prematurely wear out the Compact Flash card. It is highly recommended to implement the Enhanced Write Filter (EWF) or File-Based Write Filter (FBWF) in the OS configuration to redirect write operations to RAM, thereby protecting the CF card's physical sectors from excessive write cycles.

Commissioning & Wiring Tips

Always verify that the internal battery (which backs up the system clock) is functional before commissioning, especially if the unit has been in storage. A depleted battery can cause system time synchronization faults on boot, affecting deterministic log files. The battery is field-replaceable and located behind the front cover.

Installation Guidelines

CRITICAL WARNING

De-energize the entire system before mounting, unmounting, or modifying any module connections. Failure to isolate the power supply prior to separating the PC/104 system bus can cause permanent electrical damage to the CPU's internal ISA bus pins and connected I/O terminals.

1

Mount the CX1010-0020 CPU module onto a standard 35 mm DIN rail (EN 60715) in a vertical orientation to facilitate proper passive convection cooling.

2

Align and slide the CPU module laterally along the DIN rail to couple it with the CX1100 power supply module. Ensure the PC/104 bus connectors engage smoothly and lock the modules together using the integrated locking mechanism.

3

Insert the 128 MB Compact Flash card containing the operating system into the CF slot until it clicks securely into place.

4

Connect the RJ45 Ethernet cable to the LAN port and apply 24V DC power to the coupled CX1100 power supply module to initiate the boot sequence.

FAQ

Does the CX1010-0020 include a pre-installed TwinCAT license?

No, this specific model configuration does not come with a pre-installed TwinCAT runtime environment. Users must license and install the appropriate TwinCAT software version separately.

Can the 256 MB DDR RAM on this module be upgraded?

No, the 256 MB DDR RAM is integrated directly onto the motherboard and is not expandable or upgradeable.

What power supply module is required to run this CPU?

The CPU module does not have an onboard power supply. It must be physically coupled to a CX1100-xxxx series power supply module via the PC/104 system bus to receive power.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.