BECKHOFF

BECKHOFF CX1010-0021 CX Embedded PC CPU Module

SKU CX1010-0021

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX1010-0021

  • Country of origin:Germany

  • Product Type: CPU Modules

  • Payment: T/T, Western Union

  • Weight: 355g

  • Dimensions: 58 mm x 120 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF CX1010-0021 is a modular Embedded PC CPU module designed for DIN rail installation within industrial control applications. It serves as the core processing engine of the modular CX1010 system, coordinating automation tasks and executing control program logic. Engineered for space-saving efficiency, the module integrates essential processing, storage, and communication resources within a compact, vibration-resistant industrial housing.

Equipped with an Intel Pentium MMX-compatible processor running at 500 MHz and 256 MB of internal DDR RAM, the BECKHOFF CX1010-0021 delivers reliable execution of PLC and small-scale motion control tasks. For data storage and operating system hosting, the module features an accessible Compact Flash Type II slot with an included 128 MB CF card. A built-in 10/100 Mbit/s RJ45 Ethernet port provides communication capability for network integration, visualization, and programming interfaces.

Physical expansion of the controller is facilitated by a 16-bit ISA system bus based on the PC/104 architecture, enabling secure connection to neighboring CX modules. Because the CPU module does not incorporate an integrated power supply unit or direct I/O interfaces, it must be paired with a compatible CX1100 series power supply module. This combination provides the necessary electrical supply for the system bus while establishing physical interfaces for E-bus (EtherCAT), K-bus (Bus Terminals), or IP-Link connections.

Features

  • Intel Pentium MMX-compatible processor running at 500 MHz clock frequency.
  • 256 MB of integrated DDR RAM for program and system memory.
  • Compact Flash Type II expansion slot with a pre-installed 128 MB CF card.
  • Integrated RJ45 Ethernet interface supporting 10/100 Mbit/s transfer rates.
  • Internal battery-backed real-time clock for system date and time retention.
  • Dedicated diagnostics LEDs indicating status for power, LAN activity, LAN speed, TwinCAT status, and flash memory access.
  • Modular expansion interface utilizing a 16-bit ISA (PC/104) system bus.

Applications

  • Modular control architectures requiring DIN rail mounting in electrical enclosures.
  • Distributed industrial automation setups utilizing TwinCAT 2 control runtimes.
  • Direct interfacing to modular E-bus (EtherCAT) or K-bus (Bus Terminal) I/O systems when coupled with a CX1100 power supply.
  • Decentralized control of machines, assembly lines, and material handling systems.

Technical Specifications

Processor and Memory

Parameter Specification
Processor Type Intel Pentium MMX-compatible
Processor Clock Speed 500 MHz
Number of Cores 1
Main Memory 256 MB DDR RAM (non-expandable)
Flash Memory Slot 1 x Compact Flash Type II slot with ejector
Included Flash Memory 128 MB Compact Flash card

Interfaces and Diagnostics

Parameter Specification
Ethernet Ports 1 x RJ45 (10/100 Mbit/s)
System Bus Interface 16-bit ISA (PC/104)
Diagnostics LEDs 1 x power, 1 x LAN speed, 1 x LAN activity, TwinCAT status, 1 x flash access
System Clock Internal battery-backed clock (replaceable battery)

Electrical and Power

Parameter Specification
Power Supply Connection Via system bus (through CX1100-xxxx power supply modules)
Maximum Power Consumption 8 W

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 58 mm x 120 mm x 91 mm
Weight Approx. 355 g
Operating Temperature 0 to +50 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20

Software Compatibility

Parameter Specification
Operating Systems Windows Embedded CE 6, Windows Embedded Standard 2009
Control Software TwinCAT 2 PLC runtime, TwinCAT 2 NC PTP runtime

Installation Guidelines

  1. Ensure that all power sources to the cabinet and existing hardware are completely de-energized before mounting.
  2. Mount the CPU module onto a standard 35 mm DIN rail (EN 60715) by snapping it securely into place.
  3. Mechanically couple the CPU module to a compatible CX1100 series power supply module via the side-mounted system bus connector.
  4. Ensure that the Compact Flash card is fully inserted into the Type II slot before power-up.
  5. Make network connections to the RJ45 port using shielded Ethernet cabling to ensure electromagnetic compatibility.
  6. Verify that all modular system connections are properly aligned and locked prior to energizing the CX1100 power supply.

Replacement Recommendations

When replacing an existing unit with a new BECKHOFF CX1010-0021, safely shut down the TwinCAT runtime, turn off the system power supply, and extract the Compact Flash card containing your runtime configuration, licenses, and program files. Transfer the card to the new module to preserve existing system parameters. Ensure that the physical PC/104 system bus connector interfaces are clean and free of dust during the hardware swap.

Compliance and Certifications

  • CE Compliant
  • UL Listed

FAQ

What is the primary function of the BECKHOFF CX1010-0021 CPU module?

The BECKHOFF CX1010-0021 acts as the primary central processing unit of a modular CX1010 Embedded PC system, executing industrial PLC and motion control programs in automation environments.

How is the BECKHOFF CX1010-0021 powered?

The BECKHOFF CX1010-0021 does not include an onboard power supply. It must be powered via the system bus through a connected, compatible CX1100-xxxx series power supply module.

Does the BECKHOFF CX1010-0021 come with integrated memory?

The BECKHOFF CX1010-0021 is equipped with 256 MB of non-expandable DDR RAM and features a Compact Flash Type II slot, which includes a 128 MB CF card for operating system and application storage.

What control runtimes are supported by the BECKHOFF CX1010-0021?

The BECKHOFF CX1010-0021 supports the TwinCAT 2 PLC runtime or the TwinCAT 2 NC PTP runtime environments under Windows Embedded CE 6 or Windows Embedded Standard 2009 operating systems.

How do physical I/O modules connect to the BECKHOFF CX1010-0021?

Physical I/O connections are established by attaching a CX1100 series power supply module directly to the BECKHOFF CX1010-0021, providing the necessary interface for E-bus (EtherCAT), K-bus (Bus Terminals), or IP-Link extension.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.