BECKHOFF

Beckhoff CX1100-0930 CX Series UPS Module

SKU CX1100-0930

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX1100-0930

  • Country of origin:Germany

  • Product Type: UPS Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 95 mm x 100 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Integrating directly into the modular PC/104 bus architecture, the Beckhoff CX1100-0930 provides highly reliable, capacitive-based uninterruptible power supply capabilities for CX series Embedded PCs. This module is engineered to bridge short-term voltage fluctuations and secure volatile operational data by initiating a controlled shutdown sequence during primary power failures. By employing capacitive storage technology, it offers a maintenance-free alternative to traditional battery-backed systems, operating efficiently without risk of degradation or chemical leakage in harsh thermal environments.

Features

  • Capacitive Storage Medium: Features a 40 As capacity that eliminates regular battery maintenance intervals and shelf-life concerns.
  • Adjustable Retention Time: Provides load-dependent holdup durations that can be fully customized to meet specific system requirements.
  • Local Diagnostics indicators: Three integrated LEDs provide real-time status feedback for 24 V DC input, 24 V DC output, and capacitive charge state.
  • Embedded Bus Interface: Communicates directly via a high-speed, 16-bit ISA bus conforming to the standard PC/104 hardware layout.
  • Industrial Protection: IP20-rated housing built to resist severe industrial vibration and shock according to European standards.

Applications

  • Securing persistent memory (NOVRAM writing operations) during sudden primary power interruptions.
  • Enabling orderly, controlled OS shutdowns for Windows CE or Windows Embedded systems.
  • Protecting localized processing nodes in networks prone to voltage sags and grid fluctuations.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / Article Number CX1100-0930
Input Voltage 24 V DC (-15% / +20%)
Storage Technology Capacitive
Capacity 40 As (Ampere-seconds)
Max. Output Current 2.0 A (at 24 V DC)
Charging Current Max. 4.0 A
Retention Time Adjustable, load-dependent
CPU Bus Interface 16-bit ISA (PC/104 standard)
Max. Power Loss 2.0 W
Diagnostic Displays LEDs for 24 V DC Input, 24 V DC Output, and Charge
Protection Rating IP20
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Dimensions (W x H x D) 95 mm x 100 mm x 91 mm
Net Weight 650 g
Shipping Weight (Calculated) 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The CX1100-0930 is mechanically and electrically dedicated to the legacy CX1000 and CX1020 Embedded PC systems. If replacing an older module or a battery-backed variant (such as the CX1100-0900 series), confirm that your operating system image contains the necessary registry settings to interact with the 16-bit ISA bus address allocation. This module will not directly interface with newer CX2000 systems using PCI Express-based system interfaces.

Application Pitfalls & Engineering Notes

Because this module utilizes capacitive storage, the 40 As total energy capacity is highly dependent on the total active current draw of the CPU stack. High processing loads or extensive connected I/O terminals during a power-fail transition will drastically shorten the retention window. System integrators must design efficient, non-blocking data-dump routines in TwinCAT to write persistent data (NOVRAM) to the boot media immediately upon detecting a mains failure signal.

Commissioning & Wiring Tips

During initial commissioning, verify that the 24 V DC power supply is sized to handle the maximum charging current overhead of 4.0 A. If the primary supply exhibits a voltage sag below 20.4 V DC (the lower limit of the -15% tolerance) during the module's charging phase, the system may initiate an unintentional low-voltage shutdown sequence. Check that the "Charge" LED switches from flashing (charging active) to solid green (fully charged) within the boot-up timeline.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all 24 V DC system power before executing assembly or disassembly. Capacitive units retain an electrical charge even after primary power disconnection. Allow a minimum of three minutes for internal energy dissipation before handling the physical bus connectors or dismantling the PC/104 block.

1

Align the CX1100-0930 interface with the adjoining CX series module, ensuring the 16-bit ISA (PC/104) male and female pin connectors match precisely without offset.

2

Slide the module onto the standard DIN rail until the locking latch clicks firmly, and secure the module stack together using the mechanical side-locking mechanism.

3

Connect the 24 V DC primary supply cables to the terminals, verifying polarity, and ensure a low-impedance connection to the central functional earth terminal.

4

Energize the power source and verify that the "Input" and "Charge" LEDs illuminate, indicating active voltage input and ongoing capacitive energy buffering.

FAQ

What is the primary operational advantage of the capacitive storage in the CX1100-0930?

Unlike traditional battery backup units, capacitive storage is maintenance-free, has a significantly longer operational lifespan, works across wider thermal ranges without degradation, and avoids hazardous leakage risks.

Does this module require software drivers to operate under TwinCAT?

Yes. Proper shutdown orchestration requires the installation and configuration of the Beckhoff UPS driver on the target operating system (e.g., Windows CE or Windows Embedded) connected via the PC/104 bus.

How long can the CX1100-0930 maintain power to the CPU?

The holdup duration is load-dependent. With a total capacity of 40 As (Ampere-seconds) and a maximum output current of 2.0 A, the actual backup window varies based on the current consumption of the active CPU and connected modules.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.