BECKHOFF

BECKHOFF CX2030-N031-0003 Basic CPU Module

SKU CX2030-N031-0003

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX2030-N031-0003

  • Country of origin:Germany

  • Product Type: Basic CPU module

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

The CX2030-N031-0003 is a specialized Basic CPU module from the BECKHOFF CX2000 series, specifically configured for serial communication tasks. This module features an integrated RS485 interface via a 9-pin D-sub socket, providing reliable connectivity for industrial automation networks. It is factory-configured as a drop point with echo enabled and termination set to off, making it a tailored solution for specific communication topology requirements within the CX2030 system.

Features

  • Device Type: Basic CPU module
  • Interface: RS485 (9-pin D-sub socket)
  • Configuration: Drop point, with echo, termination off
  • Seamless integration with the CX2030 series embedded controllers

Applications

  • Industrial serial data communication
  • Multi-drop network topologies in automation control
  • Integration of legacy serial devices into EtherCAT-based control systems
  • Serial connectivity for machine and process automation

Technical Specifications

Category Specification
Manufacturer BECKHOFF
Model CX2030-N031-0003
Device Type Basic CPU module
Interface RS485
Connector D-sub socket, 9-pin
Configuration Drop point, with echo, termination off

Installation Guidelines

  • Ensure the module is properly seated within the CX2030 system housing to maintain bus contact.
  • Use a shielded 9-pin D-sub cable to connect serial devices, ensuring proper pin assignment for the RS485 signal.
  • Verify serial network settings (baud rate, parity, etc.) in the TwinCAT system manager to match the connected field device.
  • Avoid routing serial communication cables parallel to high-voltage power lines to minimize electromagnetic interference.

FAQ

What is the primary interface on the CX2030-N031-0003?

The module features an RS485 interface via a 9-pin D-sub socket.

How is the RS485 port configured by default?

It is configured as a drop point, with echo enabled and termination set to off.

Which product series is this module compatible with?

It is designed for the BECKHOFF CX2030 series embedded controller systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...