BECKHOFF

BECKHOFF CX2500-M310 PROFIBUS Fieldbus Master Module

SKU CX2500-M310

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: CX2500-M310
  • Origin Germany
  • Product Type: Fieldbus Modules
  • Payment: T/T, Western Union
  • Weight: 0.18 kg
  • Dimensions: 24 mm x 99 mm x 54.5 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF CX2500-M310 is a high-performance PROFIBUS master module designed for integration with the CX20xx series of Embedded PCs. Utilizing a high-speed PCI Express interface to connect directly to the CPU unit, this extension module enables CX2020, CX2030, CX2040, and other compatible controllers to act as master stations on a PROFIBUS network. It provides a reliable and direct communication path for distributed I/O systems and field devices.

This module supports PROFIBUS DP, DP-V1, and DP-V2 (MC) protocols, offering comprehensive fieldbus communication configurations. It features advanced configuration options, including the ability to define distinct DP cycle times for individual slave devices and customize error management profiles. This level of control ensures precise system performance and efficient handling of communication faults across complex network architectures.

Features

  • Compatible with BECKHOFF CX20xx series Embedded PCs via a high-speed PCI Express interface.
  • Supports standard PROFIBUS DP and DP-V1 protocols.
  • Equipped with a standard 9-pin D-sub socket for direct bus connection.
  • Supports network baud rates ranging from 9.6 kbaud up to 12 Mbaud.
  • Capable of controlling up to 125 PROFIBUS slave devices simultaneously.
  • Allows up to 244 bytes of input, output, parameter, configuration, or diagnostic data per slave.
  • Configurable DP cycle times independent for each slave device.
  • Freely definable error management per user/slave connection.

Applications

  • Integration of PROFIBUS-compliant field devices and drives into CX20xx PC-based control architectures.
  • Distributed I/O expansion in factory automation and machinery assembly lines.
  • Upgrade paths for existing systems transitioning from legacy PLCs to PC-based control while preserving existing PROFIBUS cabling and infrastructure.

Technical Specifications

Fieldbus Performance

Parameter Specification
Manufacturer BECKHOFF
Exact Model CX2500-M310
Fieldbus System PROFIBUS DP, DP-V1; DP-V2 (MC) in preparation
Data Transfer Rates 9.6 kbaud...12 Mbaud
Bus Interface 1 x D-sub socket, 9-pin
Maximum Bus Devices Max. 125 slaves
Maximum Data Capacity Up to 244 bytes input, output, parameter, configuration, or diagnostic data per slave

Electrical and Mechanical

Parameter Specification
Interface to CPU PCI Express (PCIe)
Max. Power Loss 2.8 W
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Weight Approx. 180 g
Protection Rating IP20

Environmental and Standards

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Verify that the main CX20xx Embedded PC system is completely powered down and de-energized before mounting.
  2. Align and securely connect the CX2500-M310 module to the left-hand side expansion interface of the CX20xx CPU block, ensuring the PCI Express connector is correctly mated.
  3. Tighten any physical mounting locks or locking mechanisms to ensure a secure and stable mechanical unit.
  4. Connect the PROFIBUS segment cable to the 9-pin D-sub connector on the front face of the module.
  5. Ensure proper grounding and shielding procedures are followed for the PROFIBUS cable to minimize electromagnetic interference.
  6. Power up the CX20xx system and utilize TwinCAT to scan, configure, and initialize the PROFIBUS master network.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF CX2500-M310?
The BECKHOFF CX2500-M310 is a physical expansion module that adds a master PROFIBUS fieldbus interface to CX20xx series Embedded PCs using a high-speed PCI Express connection interface.
How many PROFIBUS slave devices can the BECKHOFF CX2500-M310 manage?
The BECKHOFF CX2500-M310 is capable of addressing and controlling up to 125 PROFIBUS slave devices, processing up to 244 bytes of I/O, parameter, configuration, or diagnostic data per slave.
What connection interface does the BECKHOFF CX2500-M310 use for network wiring?
The BECKHOFF CX2500-M310 features a single, standard 9-pin D-sub socket on its front plate to connect directly to standard PROFIBUS network lines.
Can different slave devices run at different cycle times on the BECKHOFF CX2500-M310?
Yes, the BECKHOFF CX2500-M310 allows users to configure different DP cycle times independently for each connected slave device.
What are the operating temperature limits for the BECKHOFF CX2500-M310?
The BECKHOFF CX2500-M310 is rated to operate within a temperature range of -25 to +60 degrees Celsius in environments with up to 95% non-condensing relative humidity.
Reviews

CX2500-M310

Stock & lead time on request

Call
1 of 1

BECKHOFF CX2500-M310 PROFIBUS Fieldbus Master Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX2500-M310

  • Country of origin:Germany

  • Product Type: Fieldbus Modules

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 24 mm x 99 mm x 54.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF CX2500-M310 is a high-performance PROFIBUS master module designed for integration with the CX20xx series of Embedded PCs. Utilizing a high-speed PCI Express interface to connect directly to the CPU unit, this extension module enables CX2020, CX2030, CX2040, and other compatible controllers to act as master stations on a PROFIBUS network. It provides a reliable and direct communication path for distributed I/O systems and field devices.

This module supports PROFIBUS DP, DP-V1, and DP-V2 (MC) protocols, offering comprehensive fieldbus communication configurations. It features advanced configuration options, including the ability to define distinct DP cycle times for individual slave devices and customize error management profiles. This level of control ensures precise system performance and efficient handling of communication faults across complex network architectures.

Features

  • Compatible with BECKHOFF CX20xx series Embedded PCs via a high-speed PCI Express interface.
  • Supports standard PROFIBUS DP and DP-V1 protocols.
  • Equipped with a standard 9-pin D-sub socket for direct bus connection.
  • Supports network baud rates ranging from 9.6 kbaud up to 12 Mbaud.
  • Capable of controlling up to 125 PROFIBUS slave devices simultaneously.
  • Allows up to 244 bytes of input, output, parameter, configuration, or diagnostic data per slave.
  • Configurable DP cycle times independent for each slave device.
  • Freely definable error management per user/slave connection.

Applications

  • Integration of PROFIBUS-compliant field devices and drives into CX20xx PC-based control architectures.
  • Distributed I/O expansion in factory automation and machinery assembly lines.
  • Upgrade paths for existing systems transitioning from legacy PLCs to PC-based control while preserving existing PROFIBUS cabling and infrastructure.

Technical Specifications

Fieldbus Performance

Parameter Specification
Manufacturer BECKHOFF
Exact Model CX2500-M310
Fieldbus System PROFIBUS DP, DP-V1; DP-V2 (MC) in preparation
Data Transfer Rates 9.6 kbaud...12 Mbaud
Bus Interface 1 x D-sub socket, 9-pin
Maximum Bus Devices Max. 125 slaves
Maximum Data Capacity Up to 244 bytes input, output, parameter, configuration, or diagnostic data per slave

Electrical and Mechanical

Parameter Specification
Interface to CPU PCI Express (PCIe)
Max. Power Loss 2.8 W
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Weight Approx. 180 g
Protection Rating IP20

Environmental and Standards

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Verify that the main CX20xx Embedded PC system is completely powered down and de-energized before mounting.
  2. Align and securely connect the CX2500-M310 module to the left-hand side expansion interface of the CX20xx CPU block, ensuring the PCI Express connector is correctly mated.
  3. Tighten any physical mounting locks or locking mechanisms to ensure a secure and stable mechanical unit.
  4. Connect the PROFIBUS segment cable to the 9-pin D-sub connector on the front face of the module.
  5. Ensure proper grounding and shielding procedures are followed for the PROFIBUS cable to minimize electromagnetic interference.
  6. Power up the CX20xx system and utilize TwinCAT to scan, configure, and initialize the PROFIBUS master network.
Loading product navigation…

What is the primary function of the BECKHOFF CX2500-M310?

The BECKHOFF CX2500-M310 is a physical expansion module that adds a master PROFIBUS fieldbus interface to CX20xx series Embedded PCs using a high-speed PCI Express connection interface.

How many PROFIBUS slave devices can the BECKHOFF CX2500-M310 manage?

The BECKHOFF CX2500-M310 is capable of addressing and controlling up to 125 PROFIBUS slave devices, processing up to 244 bytes of I/O, parameter, configuration, or diagnostic data per slave.

What connection interface does the BECKHOFF CX2500-M310 use for network wiring?

The BECKHOFF CX2500-M310 features a single, standard 9-pin D-sub socket on its front plate to connect directly to standard PROFIBUS network lines.

Can different slave devices run at different cycle times on the BECKHOFF CX2500-M310?

Yes, the BECKHOFF CX2500-M310 allows users to configure different DP cycle times independently for each connected slave device.

What are the operating temperature limits for the BECKHOFF CX2500-M310?

The BECKHOFF CX2500-M310 is rated to operate within a temperature range of -25 to +60 degrees Celsius in environments with up to 95% non-condensing relative humidity.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...