Designed for space-saving DIN rail mounting, the Beckhoff CX5120-0100 serves as a robust fanless controller within the CX5100 Embedded PC series. This industrial PC features an energy-efficient Intel Atom E3815 single-core processor operating at 1.46 GHz, making it well-suited for medium-scale automation tasks requiring direct EtherCAT or Bus Terminal integration. The module includes dual independent Gigabit Ethernet ports, USB 2.0 connectivity, and a DVI-D display interface, allowing for direct visual monitoring and fast network integration.

The controller is equipped with 2 GB of non-expandable DDR3 RAM and features separate slots for CFast and microSD cards to manage operating systems and application data. An integrated 1-second UPS protects volatile memory by saving up to 1 MB of persistent data to the CFast card during power loss events. For flexible I/O configurations, the CX5120-0100 automatically detects and supports either E-bus (EtherCAT) or K-bus (Bus Terminals) connections. Note that this specific model variant is delivered without a pre-installed operating system or TwinCAT runtime license, allowing custom software provisioning.

Features

  • Single-core Intel Atom E3815 processor (1.46 GHz clock speed)
  • 2 GB DDR3 RAM onboard system memory
  • Dedicated slots for CFast card and microSD storage media (cards not included)
  • Integrated 1-second UPS for up to 1 MB of persistent diagnostic data retention
  • Automatic recognition and control of K-bus (standard Bus Terminals) and E-bus (EtherCAT Terminals)
  • High-density peripheral interfaces: 2 x RJ45 Gigabit Ethernet, 4 x USB 2.0, and 1 x DVI-D
  • Diagnostic LEDs indicating power status, TwinCAT state, flash access, and fieldbus communication activity

Applications

  • Industrial process control and automated machinery
  • Energy management systems and power distribution tracking
  • Water treatment and environmental monitoring infrastructure
  • Building management systems and HVAC plant coordination
  • High-speed industrial Ethernet and standard fieldbus integration

Ordering Information

Order Code Description
CX5120-0100 Embedded PC, Intel Atom E3815 1.46 GHz, 2 GB RAM, no OS, no TwinCAT
CX2900-0107 Factory option for ATEX, IECEx, and cFMus hazardous area certifications

Technical Specifications

Technical Parameter Specification Value
Manufacturer BECKHOFF
Model / Part Number CX5120-0100
Processor Type Intel Atom E3815, 1.46 GHz, 1 Core
System Memory 2 GB DDR3 RAM (non-expandable)
Flash Storage Interfaces 1 x CFast card slot, 1 x microSD card slot
Persistent Memory Integrated 1-second UPS, 1 MB on CFast card
Operating System None (Without Operating System)
TwinCAT Platform Level Performance (40), TwinCAT license not included
I/O Interface Support E-bus (EtherCAT) or K-bus (Bus Terminal), automatic detection
Network Interfaces 2 x RJ45 10/100/1000 Mbit/s (independent)
Display Interface 1 x DVI-D
Peripheral Interfaces 4 x USB 2.0, 1 x Optional interface slot
Input Supply Voltage 24 V DC (-15% / +20%)
Current Supply (E-bus/K-bus) 2 A
Power Consumption 11 W maximum (18 W maximum when loading UPS)
Diagnostics Indicator 1 x Power, 1 x TC Status, 1 x Flash Access, 2 x Bus Status
System Clock Internal battery-backed real-time clock (exchangeable battery)
Dimensions (W x H x D) 122 mm x 100 mm x 92 mm
Unit Weight 975 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Connector / Interface Function Description
RJ45 Port 1 & 2 Gigabit Ethernet (10/100/1000 Base-T) interfaces for network connection
DVI-D Port Digital display interface output for local HMI visual panels
USB Ports (4x) USB 2.0 interface ports for connecting mouse, keyboard, or storage
Option Slot Configurable interface port for optional Fieldbus master/slave connections
Bus Extension Interface Automatic termination interface for Beckhoff E-bus or K-bus terminals

Installation Guidelines

  • Mounting Location: Install horizontally on a standard 35 mm DIN rail (EN 60715). Ensure correct positioning to allow natural thermal convection.
  • Clearance Requirements: Keep a minimum ventilation space of 30 mm above and below the device to prevent thermal buildup in fanless configurations.
  • Earthing: Connect the functional earth terminal via the DIN rail connection and ensure low-resistance system grounding.
  • Power Cabling: Use appropriate copper wiring sized to handle the 24 V DC input and the auxiliary I/O terminal supply current.

Compliance and Certifications

  • CE, UL
  • With CX2900-0107 ordering option: ATEX (II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135 degC Dc), IECEx (Ex nA IIC T4 Gc, Ex tc IIIC T135 degC Dc), cFMus (Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, AEx ec IIC T4 Gc)

FAQ

Does the CX5120-0100 include a pre-installed operating system?

No, this specific model (CX5120-0100) is shipped without an operating system pre-installed, enabling custom software environments.

Is the system memory on this controller expandable?

No, the onboard 2 GB DDR3 RAM is fixed and cannot be expanded or upgraded.

What happens to system data during sudden power failure?

The CX5120-0100 features an integrated 1-second UPS that provides sufficient backup power to save up to 1 MB of persistent data to the CFast card.

Which fieldbus interfaces does this Embedded PC support?

The module automatically detects and interfaces with Beckhoff E-bus (EtherCAT) or K-bus (standard Bus Terminals) on the right-hand bus connector.

What are the storage options for this unit?

The PC features independent slots for both CFast and microSD cards. Note that memory cards are not included with the standard controller purchase.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.