Description

The BECKHOFF EK1300 is a dedicated EtherCAT P coupler designed to integrate standard EtherCAT Terminals (ELxxxx series) directly into 100BASE-TX EtherCAT P networks. EtherCAT P combines ultra-high-speed EtherCAT communication alongside two independent, electrically isolated 24 V DC power supplies—system and sensor supply (US) and peripheral/actuator supply (UP)—into one single standard four-wire Ethernet cable.

Housed in a compact terminal design, the BECKHOFF EK1300 features P-coded M8 connections to prevent incorrect wiring configurations in the field. The coupler generates the required E-bus operating current from the incoming system supply voltage, permitting downstream communication across all connected standard EtherCAT Terminals on the terminal strip.

Features

  • Seamless connection of standard IP20 ELxxxx EtherCAT Terminals to EtherCAT P networks
  • Two P-coded M8 interfaces for incoming network connection and continuation
  • Integrated power transmission of system/sensor supply (US) and peripheral/actuator supply (UP)
  • High-efficiency internal E-bus power supply delivering up to 2000 mA to downstream terminals
  • Onboard diagnostic and status LEDs for rapid field troubleshooting
  • Compact DIN-rail mounting with mechanical slot-and-key side-by-side terminal connection

Applications

  • Decentralized control architectures requiring clean integration of IP20 terminal assemblies
  • Single-cable machine and sensor-actuator networks
  • Power and communication distribution networks utilizing EtherCAT P infrastructure

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model EK1300
Product Type EtherCAT P Coupler
Task in System Coupling of EtherCAT Terminals (ELxxxx) to 100BASE-TX EtherCAT P networks
Data Transfer Medium Shielded EtherCAT P cable
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Power Supply From EtherCAT P (24 V DC for US and UP)
Total Current Max. 3 A per US and UP
Current Consumption from US 40 mA + (sum of E-bus current / 4)
Current Consumption from UP Typ. 4 mA
Current Supply E-bus 2000 mA
Current Rating per Port Max. 3 A per US and UP
Electrical Isolation 500 V (power contact / supply voltage / Ethernet)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP20
Installation Position Variable
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715) with lock
Dimensions (W x H x D) 44 mm x 100 mm x 68 mm

Installation Guidelines

  1. Ensure that the entire electrical installation is de-energized before mounting, wiring, or configuring the system.
  2. Mount the BECKHOFF EK1300 onto a standard 35 mm DIN rail (EN 60715) until the integrated locking mechanism engages securely.
  3. Slide standard ELxxxx series EtherCAT Terminals onto the rail next to the coupler, using the double slot-and-key system for secure mechanical and electrical E-bus coupling.
  4. Connect the incoming EtherCAT P cable to the designated P-coded M8 socket, tightening the screw connector to secure the shield connection.
  5. Verify that the combined current draw of all downstream terminals does not exceed the maximum E-bus current supply of 2000 mA.

Compliance and Certifications

  • CE
  • UL
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF EK1300?
The BECKHOFF EK1300 is designed to couple standard IP20 EtherCAT Terminals (ELxxxx series) to a 100BASE-TX EtherCAT P network, supplying both communication and power through a single cable interface.
What connector interface does the BECKHOFF EK1300 use?
The BECKHOFF EK1300 uses two shielded, screw-type, P-coded M8 sockets to securely handle both incoming EtherCAT P signals and network continuation.
How much current can the BECKHOFF EK1300 supply to connected terminals?
The BECKHOFF EK1300 provides up to 2000 mA of current to the connected E-bus terminal strip.
What are the power requirements for the BECKHOFF EK1300?
The BECKHOFF EK1300 is powered directly from the EtherCAT P line, utilizing 24 V DC for both the US (system/sensor) and UP (peripheral/actuator) power supplies, with a maximum current limit of 3 A per supply line.
What protection rating does the BECKHOFF EK1300 possess?
The BECKHOFF EK1300 carries an IP20 protection rating and is designed for cabinet installation on standard 35 mm DIN rails.
Reviews

EK1300

Stock & lead time on request

Call
1 of 1

BECKHOFF EK1300 EtherCAT P Coupler

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EK1300

  • Country of origin:Germany

  • Product Type: EtherCAT P Couplers

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Dimensions: 44 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF EK1300 is a dedicated EtherCAT P coupler designed to integrate standard EtherCAT Terminals (ELxxxx series) directly into 100BASE-TX EtherCAT P networks. EtherCAT P combines ultra-high-speed EtherCAT communication alongside two independent, electrically isolated 24 V DC power supplies—system and sensor supply (US) and peripheral/actuator supply (UP)—into one single standard four-wire Ethernet cable.

Housed in a compact terminal design, the BECKHOFF EK1300 features P-coded M8 connections to prevent incorrect wiring configurations in the field. The coupler generates the required E-bus operating current from the incoming system supply voltage, permitting downstream communication across all connected standard EtherCAT Terminals on the terminal strip.

Features

  • Seamless connection of standard IP20 ELxxxx EtherCAT Terminals to EtherCAT P networks
  • Two P-coded M8 interfaces for incoming network connection and continuation
  • Integrated power transmission of system/sensor supply (US) and peripheral/actuator supply (UP)
  • High-efficiency internal E-bus power supply delivering up to 2000 mA to downstream terminals
  • Onboard diagnostic and status LEDs for rapid field troubleshooting
  • Compact DIN-rail mounting with mechanical slot-and-key side-by-side terminal connection

Applications

  • Decentralized control architectures requiring clean integration of IP20 terminal assemblies
  • Single-cable machine and sensor-actuator networks
  • Power and communication distribution networks utilizing EtherCAT P infrastructure

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model EK1300
Product Type EtherCAT P Coupler
Task in System Coupling of EtherCAT Terminals (ELxxxx) to 100BASE-TX EtherCAT P networks
Data Transfer Medium Shielded EtherCAT P cable
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Power Supply From EtherCAT P (24 V DC for US and UP)
Total Current Max. 3 A per US and UP
Current Consumption from US 40 mA + (sum of E-bus current / 4)
Current Consumption from UP Typ. 4 mA
Current Supply E-bus 2000 mA
Current Rating per Port Max. 3 A per US and UP
Electrical Isolation 500 V (power contact / supply voltage / Ethernet)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP20
Installation Position Variable
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715) with lock
Dimensions (W x H x D) 44 mm x 100 mm x 68 mm

Installation Guidelines

  1. Ensure that the entire electrical installation is de-energized before mounting, wiring, or configuring the system.
  2. Mount the BECKHOFF EK1300 onto a standard 35 mm DIN rail (EN 60715) until the integrated locking mechanism engages securely.
  3. Slide standard ELxxxx series EtherCAT Terminals onto the rail next to the coupler, using the double slot-and-key system for secure mechanical and electrical E-bus coupling.
  4. Connect the incoming EtherCAT P cable to the designated P-coded M8 socket, tightening the screw connector to secure the shield connection.
  5. Verify that the combined current draw of all downstream terminals does not exceed the maximum E-bus current supply of 2000 mA.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the primary function of the BECKHOFF EK1300?

The BECKHOFF EK1300 is designed to couple standard IP20 EtherCAT Terminals (ELxxxx series) to a 100BASE-TX EtherCAT P network, supplying both communication and power through a single cable interface.

What connector interface does the BECKHOFF EK1300 use?

The BECKHOFF EK1300 uses two shielded, screw-type, P-coded M8 sockets to securely handle both incoming EtherCAT P signals and network continuation.

How much current can the BECKHOFF EK1300 supply to connected terminals?

The BECKHOFF EK1300 provides up to 2000 mA of current to the connected E-bus terminal strip.

What are the power requirements for the BECKHOFF EK1300?

The BECKHOFF EK1300 is powered directly from the EtherCAT P line, utilizing 24 V DC for both the US (system/sensor) and UP (peripheral/actuator) power supplies, with a maximum current limit of 3 A per supply line.

What protection rating does the BECKHOFF EK1300 possess?

The BECKHOFF EK1300 carries an IP20 protection rating and is designed for cabinet installation on standard 35 mm DIN rails.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...