Description
The BECKHOFF EL1889 digital input terminal is designed to acquire binary control signals from the physical field level and transmit them to the higher-level automation controller via the EtherCAT network. Featuring a highly compact High Density (HD) housing, this terminal provides sixteen distinct input points within a 12 mm physical width to optimize control cabinet space utilization.
This terminal is built for 1-wire connection technology and operates with ground-switching (sinking) sensors. The BECKHOFF EL1889 processes 24 V DC signals, identifying a logical "1" status at low voltage levels (0 to 7 V) and a logical "0" status at higher voltage levels (18 to 30 V). High-density connection terminals allow direct wiring of solid-wire conductors without additional tools, facilitating efficient high-density installations.
Features
- Provides 16 digital input points in a compact 12 mm housing width
- Engineered for ground-switching (sinking) input characteristics
- Utilizes space-saving 1-wire connection technology
- Equipped with integrated signal status LEDs for each input channel
- High Density (HD) terminal design with toolless direct plug-in connection for solid conductors
Applications
- High-density distributed input/output configurations within automated machine environments
- Direct integration with ground-switching (sinking) proximity sensors, limit switches, and photoelectric sensors
- EtherCAT-based control systems demanding high-density signal acquisition within limited cabinet space
Technical Specifications
General
| Manufacturer |
BECKHOFF |
| Model |
EL1889 |
| Product Type |
EtherCAT Terminal |
| Design Form |
HD (High Density) housing with signal LEDs |
| Housing Material |
Polycarbonate |
Electrical
| Nominal Voltage |
24 V DC (-15% / +20%) |
| "0" Signal Voltage |
18 to 30 V (Sinking Logic) |
| "1" Signal Voltage |
0 to 7 V (Sinking Logic) |
| Input Current |
typ. 3.0 mA |
| Input Filter Delay |
typ. 3.0 ms |
| Current Consumption E-bus |
typ. 110 mA |
| Current Consumption Power Contacts |
typ. 35 mA |
| Current Load Power Contacts (Imax) |
10 A |
| Electrical Isolation |
500 V (E-bus/field potential) |
Connection and Mechanical
| Connection Technology |
1-wire |
| Number of Inputs |
16 |
| Solid Wire Connection Cross-Section |
0.08 to 1.5 mm² (AWG 28 to 16) |
| Stranded Wire Connection Cross-Section |
0.25 to 1.5 mm² (AWG 22 to 16) |
| Fine-Stranded Wire (with Ferrule) |
0.14 to 0.75 mm² (AWG 26 to 19) |
| Stripping Length |
8 to 9 mm |
| Dimensions (W x H x D) |
12 mm x 100 mm x 68 mm |
| Mounting |
35 mm DIN rail (conforming to EN 60715) with lock |
Environmental and Regulatory
| Operating Temperature |
-25 to +60 degC |
| Storage Temperature |
-40 to +85 degC |
| Relative Humidity |
95%, no condensation |
| Vibration/Shock Resistance |
Conforms to EN 60068-2-6 / EN 60068-2-27 |
| EMC Immunity/Emission |
Conforms to EN 61000-6-2 / EN 61000-6-4 |
| Protection Class |
IP20 |
| Approvals |
CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc) |
Installation Guidelines
- Ensure the entire industrial control system and power supplies are completely de-energized before mounting or wiring the terminal.
- Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, securing it using the integrated locking mechanism.
- Slide successive terminals together using the double slot-and-key design to ensure correct E-bus and power contact engagement.
- Connect the solid wiring by pushing the conductor directly into the plug-in terminal point. For fine-stranded conductors, press the spring actuator down with a screwdriver before inserting the wire.
- Ensure field power voltage is correctly configured within the nominal 24 V DC tolerance range before turning on the power.