1 of 1

BECKHOFF EL1904 EtherCAT TwinSAFE Digital Input Terminal

BECKHOFF EL1904 EtherCAT TwinSAFE Digital Input Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL1904

  • Country of origin:Germany

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 50g

  • Dimensions: 6.8cm x 1.2cm x 10cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The EL1904 (EL1904) is a specialized EtherCAT Terminal designed for functional safety within the Beckhoff TwinSAFE ecosystem. This 4-channel digital input terminal allows for the direct connection of safety-related sensors, such as emergency stop buttons, light curtains, and safety switches, to the EtherCAT I/O system. Operating at 24 VDC, the EL1904 fulfills the most stringent safety requirements by utilizing the Safety over EtherCAT (FSoE) protocol, enabling seamless integration of safety and standard automation data on the same network. By decentralizing safety logic and providing high-density monitoring in a compact 12 mm housing, this module is critical for reducing wiring overhead in complex manufacturing cells, power plants, and automated assembly lines while ensuring SIL 3/Category 4 protection levels.

Technical Configuration (Deep Dive)

The EL1904 architecture is built around the TwinSAFE protocol, which ensures data integrity through diverse signal processing.

  • TwinSAFE/FSoE Protocol: The terminal communicates via the Safety over EtherCAT protocol, where safety-related data is encapsulated within standard EtherCAT frames. This "black channel" approach allows for safety communication across any standard network media without compromising the safety function.

  • Safety Logic Integration: Each of the four channels features a parameterizable input filter. The module performs internal cross-checking of the input signals and the FSoE communication. If a fault is detected (e.g., a communication timeout or internal hardware failure), the terminal enters a "Safe State" within the defined fault response time, typically governed by the watchdog timer settings.

  • Wiring Versatility: Supporting both 1-wire and 2-wire connection technologies, the terminal provides flexibility for various sensor types. The tension clamp system allows for rapid wiring of solid or stranded conductors, ensuring vibration-proof connections in harsh industrial environments.

Technical Specifications

Parameter Specification Details
Model EL1904
Brand BECKHOFF
Origin Germany
Number of Inputs 4 Safety Digital Inputs
Connection Type 1-/2-wire technology
Protocol TwinSAFE / Safety over EtherCAT (FSoE)
Response Time Typ. 4 ms (read input/write to E-bus)
Current Consumption Typ. 200 mA (E-bus)
Dimensions 100 mm x 12 mm x 68 mm
Weight 0.05 kg (Shipping weight 2 kg)
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715)
Protection Rating IP20

Technical FAQs

  • What is the "Watchdog Time" and how does it affect the fault response?

    The watchdog time is a parameterizable safety timing window. If the EL1904 does not receive a valid FSoE frame within this period, it automatically triggers a fault response and moves to a safe state. This ensures that a loss of communication is handled with the same priority as a physical emergency stop trigger.

  • Can the EL1904 be used without a TwinSAFE Logic terminal?

    No. The EL1904 functions as a safety "alias" device. It requires a TwinSAFE Logic terminal (such as an EL6910 or an integrated Safety PLC) to process the safety signals and execute the programmed safety logic.

  • What is the maximum current load for the power contacts?

    The EL1904 is rated for a maximum current load of 10 A through the power contacts. It is essential to calculate the total current draw of all downstream terminals in the segment to ensure this limit is not exceeded.


Engineering & Installation Guide

  • Spring-Clamp Termination: For optimal reliability, strip conductors to exactly 8-9 mm. When using flexible stranded wire, the use of ferrules is recommended (0.14 to 1.5 mm²) to prevent fraying and potential short circuits between the high-density terminal points.

  • Horizontal Thermal Management: The EL1904 is designed for horizontal installation on a 35 mm DIN rail. Ensure that the double slot and key connection is firmly engaged with adjacent terminals to maintain the integrity of the E-bus and power contacts. Maintain adequate clearance above and below the terminal row for natural convection cooling.

  • Shielding for Safety Integrity: To prevent nuisance tripping from electromagnetic interference, ensure that all safety sensor cables are properly routed away from high-voltage motor leads. For long cable runs, utilize shielded cables grounded at the entry point of the control cabinet.

Engineering Advantages

The EL1904 stands out for its extreme reliability in high-vibration environments, characterized by its robust polycarbonate housing and spring-actuated wiring. Its primary advantage lies in "Safety-at-the-Point-of-Use"—by placing safety inputs directly on the EtherCAT segment, engineers eliminate the need for long, expensive home-run wiring to a central safety relay. This modularity allows for rapid machine expansion; adding another safety zone is as simple as clipping an EL1904 onto the DIN rail and updating the TwinSAFE logic configuration.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Yellow
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...