Description

The BECKHOFF EL3162 is an EtherCAT Terminal featuring two analog input channels designed for voltage signals ranging from 0 to 10 V. Engineered with a 16-bit resolution in a single-ended configuration, this terminal processes analog field signals and transmits them directly to the automation controller via the high-speed EtherCAT network.

Integrated within the modular BECKHOFF I/O system, the EL3162 provides advanced signal processing capabilities including activatable FIR and IIR filters, limit value monitoring, and support for distributed clocks to ensure precise time synchronization across the industrial network. Power for the internal electronics is supplied via the E-bus, while standard compact process imagery optimizes data exchange with the master controller.

Features

  • 2-channel analog input terminal for voltage measurement in the 0 to 10 V range
  • 16-bit resolution including sign for high-precision data acquisition
  • Single-ended input technology with an internal resistance greater than 200 kOhm
  • Distributed clocks support for synchronous data acquisition across the network
  • Activatable FIR and IIR filters for adjustable signal conditioning
  • Integrated limit value monitoring for threshold-based event handling
  • Electrical isolation of 500 V between the E-bus and signal voltage

Applications

  • Industrial analog sensor data acquisition and monitoring
  • Process control systems requiring precise voltage measurement
  • Machine automation for position, pressure, or flow feedback
  • Synchronized data logging applications utilizing distributed clocks

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3162
Product Type EtherCAT Terminal
Number of Inputs 2 (single-ended)
Country of Origin Germany

Electrical

Parameter Specification
Power Supply Via the E-bus
Current Consumption E-bus Typ. 170 mA
Current Consumption Power Contacts -
Dielectric Strength Max. 30 V
Electrical Isolation 500 V (E-bus / signal voltage)
Current Load Power Contacts Imax: 10 A

Signal and Performance

Parameter Specification
Signal Type Single-ended voltage
Signal Voltage 0 to 10 V
Internal Resistance > 200 kOhm
Resolution 16 bit (incl. sign)
Conversion Time ~ 50 us
Measuring Error < ±0.3 % (relative to full scale value)
Input Filter Limit Frequency 5 kHz
Distributed Clocks Yes
Bit Width in the Process Image 2 x 16 bit input, 2 x 8 bit status

Connection and Mechanical

Parameter Specification
Connection Technology Spring actuation by screwdriver
Connection Cross-Section Solid Conductor (s) 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section Stranded Conductor (st) 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section with Ferrule (f) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm
Pluggable Wiring For all ESxxxx terminals
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight Approx. 60 g
Material Polycarbonate
Installation On 35 mm DIN rail conforming to EN 60715 with lock

Environmental and Approvals

Parameter Specification
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Protection Rating IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals/Markings CE, UL, ATEX
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  1. Ensure the entire control system is de-energized and locked out before performing any mechanical or electrical work.
  2. Inspect the terminal housing and connection points for any visible transit damage.
  3. Mount the BECKHOFF EL3162 onto a standard 35 mm DIN rail (EN 60715) alongside existing terminals using the double slot and key connection.
  4. Strip field conductors to the specified length (8 to 9 mm) and insert solid, stranded, or ferrule-equipped wires into the spring-actuated connection points using a suitable screwdriver.
  5. Verify correct potential distribution, field-side supply, and E-bus connection integrity across adjacent terminals.
  6. Power on the system and verify operational status via the onboard diagnostic LEDs before initiating software configuration in TwinCAT.

FAQ

What is the BECKHOFF EL3162 EtherCAT Terminal and what are its primary functions?

The BECKHOFF EL3162 is a modular EtherCAT terminal featuring two analog input channels specifically designed for voltage signals ranging from 0 to 10 V. Engineered with a 16-bit resolution in a single-ended configuration, it processes field signals and transmits them directly to the automation controller over a high-speed EtherCAT network. Additionally, the unit incorporates advanced signal processing capabilities like activatable FIR and IIR filters for precise data conditioning.

How are power and communication supplied to the BECKHOFF EL3162?

The BECKHOFF EL3162 receives its internal electronics power supply directly via the E-bus connection from the automation system. It consumes a typical current of 170 mA from the E-bus while facilitating compact process imagery for seamless data exchange with the master controller. Electrical isolation of 500 V is maintained between the E-bus and the field signal voltage to protect internal components.

Does the BECKHOFF EL3162 support synchronized data acquisition across industrial networks?

Yes, the BECKHOFF EL3162 fully supports distributed clocks, ensuring highly accurate time synchronization across multiple devices in the industrial network. This feature is crucial for applications requiring coordinated data logging, synchronized multi-axis machine feedback, and precise control loops. The conversion time of approximately 50 microseconds further optimizes fast-paced industrial automation processes.

What type of physical connections and wiring are compatible with the BECKHOFF EL3162?

The BECKHOFF EL3162 utilizes spring-actuated connection technology that is operated easily using a standard screwdriver. It accepts solid, stranded, or ferrule-equipped conductors with cross-sections ranging from 0.08 to 2.5 mm² (AWG 28 to 14) depending on the wire type used. Conductors should be stripped to a length of 8 to 9 mm prior to insertion into the spring terminals.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.