BECKHOFF

BECKHOFF EL3751-0020 EtherCAT Terminal

SKU EL3751-0020

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EL3751-0020
  • Origin Germany
  • Product Type: EtherCAT Terminals
  • Payment: T/T, Western Union
  • Weight: 0.065 kg
  • Dimensions: 12 mm x 100 mm x 68 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

Designed to meet stringent measurement requirements in industrial automation environments, the EL3751-0020 multi-function analog input EtherCAT terminal delivers high-precision signal acquisition. This module enables the acquisition of analog signals with high accuracy under harsh operational conditions. It features a single multi-functional input channel supporting differential connections across 2-, 3-, 4-, 5-, and 6-wire setups, making it highly versatile for interfacing with various industrial sensors, including strain gauges, RTDs, and potentiometers.

Operating with a high-resolution 24-bit analog-to-digital converter, this module achieves a sampling rate up to 10 ksps (kilosamples per second). With integrated distributed clocks, the terminal synchronizes measurement values with sub-microsecond precision across the EtherCAT network. It comes factory calibrated, ensuring reliable measurement accuracy straight from installation without requiring field calibration.

Features

  • High-precision 24-bit resolution with an integrated sign bit.
  • Fast conversion speed of 100 us per sample (10 ksps sampling rate).
  • Oversampling capability with a configurable factor of n = 1 to 64.
  • Distributed clock synchronization with jitter specifications well under 1 us.
  • Support for multi-wire connections (2-, 3-, 4-, 5-, and 6-wire) with differential inputs.
  • Integrated parameterizable power supply for strain gauge sensors (0.5 to 5 V).
  • Extended range performance of 107% with a free numeric filter, TrueRMS calculations, and an integrated peak-hold function.

Applications

  • High-speed weight and force measurement applications using strain gauges.
  • Precision temperature monitoring with multi-wire RTD sensors.
  • Test bench systems requiring fast, synchronized signal oversampling.
  • Industrial processes requiring high-end feedback control loops in machine building.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model EL3751-0020
Product Type EtherCAT Terminal (Analog Input)
Number of Inputs 1
Power Supply Via E-bus
Input Technology Differential input (2-, 3-, 4-, 5-, 6-wire connection)
Oversampling Factor n = 1 to 64
Distributed Clocks Yes, precision < 1 us
Internal Resistance > 500 kOhm (30 V range), > 4 MOhm (other voltage ranges), 150 Ohm (current range)
Input Filter Limit Frequency 3 kHz
Resolution 24 bit (including sign)
Conversion Time 100 us / 10 ksps
Electrical Isolation 500 V (E-bus / signal voltage)
E-bus Current Consumption Typically 260 mA
Dielectric Strength Maximum 36 V
Weight 65 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Enclosure Material Polycarbonate
Protection Rating IP20

Connections and Interfaces

Connection Property Specification
Wiring Type Solid conductor (e), flexible conductor (f), and ferrule (a) via spring actuation
Solid Wire Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Stranded Wire Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Ferruled Wire Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Installation Guidelines

  • Mount vertically or horizontally on a standard 35 mm DIN rail conforming to EN 60715.
  • Ensure secure engagement of the double slot and key connection for reliable backplane contact.
  • Use shielded cables for all analog signal paths and connect shields to a low-impedance ground close to the terminal.
  • Maintain clear ventilation space around the terminal to preserve the rated ambient temperature limit.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 and EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 and EN 60068-2-27
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Beckhoff EL3751-0020?
The Beckhoff EL3751-0020 is a 1-channel multi-functional analog input EtherCAT terminal with 24-bit resolution and a sampling rate of up to 10 ksps, designed for high-precision differential measurements.
Does this terminal support strain gauge measurements?
Yes, it features an integrated, parameterizable power supply for strain gauges (0.5 to 5 V) and supports 2-, 3-, 4-, 5-, and 6-wire connection configurations.
What are the environmental operating limits for this module?
The operating temperature range is 0 to +55 degC, with a non-condensing relative humidity tolerance of up to 95%.
Does the EL3751-0020 support EtherCAT Distributed Clocks?
Yes, it supports EtherCAT Distributed Clocks (DC) with synchronization precision of less than 1 us.
Reviews

EL3751-0020

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF EL3751-0020 EtherCAT Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3751-0020

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 65g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed to meet stringent measurement requirements in industrial automation environments, the EL3751-0020 multi-function analog input EtherCAT terminal delivers high-precision signal acquisition. This module enables the acquisition of analog signals with high accuracy under harsh operational conditions. It features a single multi-functional input channel supporting differential connections across 2-, 3-, 4-, 5-, and 6-wire setups, making it highly versatile for interfacing with various industrial sensors, including strain gauges, RTDs, and potentiometers.

Operating with a high-resolution 24-bit analog-to-digital converter, this module achieves a sampling rate up to 10 ksps (kilosamples per second). With integrated distributed clocks, the terminal synchronizes measurement values with sub-microsecond precision across the EtherCAT network. It comes factory calibrated, ensuring reliable measurement accuracy straight from installation without requiring field calibration.

Features

  • High-precision 24-bit resolution with an integrated sign bit.
  • Fast conversion speed of 100 us per sample (10 ksps sampling rate).
  • Oversampling capability with a configurable factor of n = 1 to 64.
  • Distributed clock synchronization with jitter specifications well under 1 us.
  • Support for multi-wire connections (2-, 3-, 4-, 5-, and 6-wire) with differential inputs.
  • Integrated parameterizable power supply for strain gauge sensors (0.5 to 5 V).
  • Extended range performance of 107% with a free numeric filter, TrueRMS calculations, and an integrated peak-hold function.

Applications

  • High-speed weight and force measurement applications using strain gauges.
  • Precision temperature monitoring with multi-wire RTD sensors.
  • Test bench systems requiring fast, synchronized signal oversampling.
  • Industrial processes requiring high-end feedback control loops in machine building.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model EL3751-0020
Product Type EtherCAT Terminal (Analog Input)
Number of Inputs 1
Power Supply Via E-bus
Input Technology Differential input (2-, 3-, 4-, 5-, 6-wire connection)
Oversampling Factor n = 1 to 64
Distributed Clocks Yes, precision < 1 us
Internal Resistance > 500 kOhm (30 V range), > 4 MOhm (other voltage ranges), 150 Ohm (current range)
Input Filter Limit Frequency 3 kHz
Resolution 24 bit (including sign)
Conversion Time 100 us / 10 ksps
Electrical Isolation 500 V (E-bus / signal voltage)
E-bus Current Consumption Typically 260 mA
Dielectric Strength Maximum 36 V
Weight 65 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Enclosure Material Polycarbonate
Protection Rating IP20

Connections and Interfaces

Connection Property Specification
Wiring Type Solid conductor (e), flexible conductor (f), and ferrule (a) via spring actuation
Solid Wire Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Stranded Wire Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Ferruled Wire Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Installation Guidelines

  • Mount vertically or horizontally on a standard 35 mm DIN rail conforming to EN 60715.
  • Ensure secure engagement of the double slot and key connection for reliable backplane contact.
  • Use shielded cables for all analog signal paths and connect shields to a low-impedance ground close to the terminal.
  • Maintain clear ventilation space around the terminal to preserve the rated ambient temperature limit.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 and EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 and EN 60068-2-27

What is the primary function of the Beckhoff EL3751-0020?

The Beckhoff EL3751-0020 is a 1-channel multi-functional analog input EtherCAT terminal with 24-bit resolution and a sampling rate of up to 10 ksps, designed for high-precision differential measurements.

Does this terminal support strain gauge measurements?

Yes, it features an integrated, parameterizable power supply for strain gauges (0.5 to 5 V) and supports 2-, 3-, 4-, 5-, and 6-wire connection configurations.

What are the environmental operating limits for this module?

The operating temperature range is 0 to +55 degC, with a non-condensing relative humidity tolerance of up to 95%.

Does the EL3751-0020 support EtherCAT Distributed Clocks?

Yes, it supports EtherCAT Distributed Clocks (DC) with synchronization precision of less than 1 us.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...