BECKHOFF

BECKHOFF EL3751-0020 EtherCAT Terminal

SKU EL3751-0020

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: EL3751-0020

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 65g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed to meet stringent measurement requirements in industrial automation environments, the EL3751-0020 multi-function analog input EtherCAT terminal delivers high-precision signal acquisition. This module enables the acquisition of analog signals with high accuracy under harsh operational conditions. It features a single multi-functional input channel supporting differential connections across 2-, 3-, 4-, 5-, and 6-wire setups, making it highly versatile for interfacing with various industrial sensors, including strain gauges, RTDs, and potentiometers.

Operating with a high-resolution 24-bit analog-to-digital converter, this module achieves a sampling rate up to 10 ksps (kilosamples per second). With integrated distributed clocks, the terminal synchronizes measurement values with sub-microsecond precision across the EtherCAT network. It comes factory calibrated, ensuring reliable measurement accuracy straight from installation without requiring field calibration.

Features

  • High-precision 24-bit resolution with an integrated sign bit.
  • Fast conversion speed of 100 us per sample (10 ksps sampling rate).
  • Oversampling capability with a configurable factor of n = 1 to 64.
  • Distributed clock synchronization with jitter specifications well under 1 us.
  • Support for multi-wire connections (2-, 3-, 4-, 5-, and 6-wire) with differential inputs.
  • Integrated parameterizable power supply for strain gauge sensors (0.5 to 5 V).
  • Extended range performance of 107% with a free numeric filter, TrueRMS calculations, and an integrated peak-hold function.

Applications

  • High-speed weight and force measurement applications using strain gauges.
  • Precision temperature monitoring with multi-wire RTD sensors.
  • Test bench systems requiring fast, synchronized signal oversampling.
  • Industrial processes requiring high-end feedback control loops in machine building.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model EL3751-0020
Product Type EtherCAT Terminal (Analog Input)
Number of Inputs 1
Power Supply Via E-bus
Input Technology Differential input (2-, 3-, 4-, 5-, 6-wire connection)
Oversampling Factor n = 1 to 64
Distributed Clocks Yes, precision < 1 us
Internal Resistance > 500 kOhm (30 V range), > 4 MOhm (other voltage ranges), 150 Ohm (current range)
Input Filter Limit Frequency 3 kHz
Resolution 24 bit (including sign)
Conversion Time 100 us / 10 ksps
Electrical Isolation 500 V (E-bus / signal voltage)
E-bus Current Consumption Typically 260 mA
Dielectric Strength Maximum 36 V
Weight 65 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Enclosure Material Polycarbonate
Protection Rating IP20

Connections and Interfaces

Connection Property Specification
Wiring Type Solid conductor (e), flexible conductor (f), and ferrule (a) via spring actuation
Solid Wire Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Stranded Wire Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Ferruled Wire Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Installation Guidelines

  • Mount vertically or horizontally on a standard 35 mm DIN rail conforming to EN 60715.
  • Ensure secure engagement of the double slot and key connection for reliable backplane contact.
  • Use shielded cables for all analog signal paths and connect shields to a low-impedance ground close to the terminal.
  • Maintain clear ventilation space around the terminal to preserve the rated ambient temperature limit.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 and EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 and EN 60068-2-27

FAQ

What is the primary function of the Beckhoff EL3751-0020?

The Beckhoff EL3751-0020 is a 1-channel multi-functional analog input EtherCAT terminal with 24-bit resolution and a sampling rate of up to 10 ksps, designed for high-precision differential measurements.

Does this terminal support strain gauge measurements?

Yes, it features an integrated, parameterizable power supply for strain gauges (0.5 to 5 V) and supports 2-, 3-, 4-, 5-, and 6-wire connection configurations.

What are the environmental operating limits for this module?

The operating temperature range is 0 to +55 degC, with a non-condensing relative humidity tolerance of up to 95%.

Does the EL3751-0020 support EtherCAT Distributed Clocks?

Yes, it supports EtherCAT Distributed Clocks (DC) with synchronization precision of less than 1 us.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.