1 of 1

BECKHOFF EL3413 EtherCAT Terminal: 3-Phase Power Measurement

BECKHOFF EL3413 EtherCAT Terminal: 3-Phase Power Measurement

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3413

  • Country of origin:Germany

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The EL3413 is a high-precision, 3-phase EtherCAT Terminal designed for comprehensive power measurement of alternating voltages up to 690 V AC. It is engineered to monitor energy consumption and power quality directly within the EtherCAT system. With its ability to perform harmonic analysis and measure effective, reactive, and apparent power, the EL3413 is an essential component for energy management and grid monitoring applications.

Features

  • 3-Phase Power Measurement: Capable of monitoring 3-phase systems, with optional single-phase operation.
  • Extensive Measured Values: Provides data for current (I1, I2, I3, In), voltage, effective/reactive/apparent power, energy, cos φ, frequency, and harmonic analysis.
  • Galvanic Isolation: High electrical isolation (4500 V) and galvanically isolated current inputs ensure safety and measurement accuracy.
  • Flexible Current Input: Adjustable range for current measurement: 100 mA, 1 A (default), and 5 A.
  • Compact Design: 12 mm wide housing for high-density DIN rail mounting in control cabinets.

Applications

  • Industrial energy monitoring and cost optimization
  • Power quality analysis in electrical grids
  • Monitoring of machinery energy efficiency
  • Preventive maintenance for motor-driven systems

Technical Specifications

Category Specification
Manufacturer BECKHOFF
Model EL3413
Measuring Voltage Max. 690 V AC (3-phase)
Measuring Current Adjustable (100 mA, 1 A, 5 A)
Electrical Isolation 4500 V
Resolution 1 μA, 0.1 mV, 10 mW
Measuring Error 0.5 % (U/I), 1 % (calculated values)
Current Consumption (E-bus) typ. 160 mA
Operating Temperature -25 to +60 degC
Protection Rating IP20
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm

Installation Guidelines

  • Mount on a 35 mm DIN rail (EN 60715) using the integrated lock mechanism.
  • Ensure proper wiring for 3-phase voltage and current inputs, utilizing the spring-actuated terminals for solid or flexible conductors (stripping length 8–9 mm).
  • Adhere to all local electrical safety regulations when connecting high-voltage (up to 690 V AC) circuits.
  • Follow EMC immunity standards (EN 61000-6-2/EN 61000-6-4) for cabinet wiring to prevent electromagnetic interference with power data.
  • Ensure consistent ambient conditions between -25 and +60 degC.

What is the maximum measuring voltage for the EL3413?

It can measure up to 690 V AC in a 3-phase system.

Does the EL3413 perform harmonic analysis?

Yes, it features integrated harmonic analysis as part of its power monitoring capabilities.

What is the adjustable range for the current inputs?

The current measurement range can be adjusted to 100 mA, 1 A (default), or 5 A.

Is the EL3413 suitable for single-phase operation?

Yes, it supports optional single-phase operation in addition to 3-phase measurement.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...