1 of 1

Beckhoff EL3602 EtherCAT Terminal 2-channel High-Precision Analog Input Module

Beckhoff EL3602 EtherCAT Terminal 2-channel High-Precision Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3602

  • Country of origin:Germany

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 120 mm x 80 mm x 25 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for high-accuracy voltage measurement within automated control topologies, the Beckhoff EL3602 is a dual-channel analog input terminal operating on the EtherCAT protocol. This high-precision module processes differential input signals across several user-configurable voltage ranges, providing reliable 24-bit resolution to the central control system. Optimized for applications requiring exceptional signal fidelity, it features electrical isolation and robust integrated filters to manage electrical noise in demanding industrial environments.

Features

  • Two independent, differential analog input channels.
  • Parameterizable measurement ranges: +/-10 V, +/-5 V, +/-2.5 V, and +/-1.25 V.
  • Exceptional 24-bit resolution (including sign) for microscopic voltage tracking.
  • Extremely low measurement error of less than +/-0.01 percent at 25 degC (relative to full scale).
  • Galvanic isolation of 500 V between the internal E-bus and the input channels.
  • Configurable conversion times ranging from 1 ms to 400 ms (20 ms default).

Applications

  • High-precision automated test benches and calibration systems.
  • Process monitoring in semiconductor manufacturing and laboratory environments.
  • Tension and load monitoring loops requiring highly stable differential voltage feedback.
  • Multi-axis motion systems needing micro-positioning analog feedback.

Technical Specifications

Specification Parameter Value
Manufacturer Beckhoff
Model Series EL3602 (EtherCAT Terminal Series)
Number of Inputs 2 (Differential)
Signal Voltage Ranges -10 to +10 V, -5 to +5 V, -2.5 to +2.5 V, -1.25 to +1.25 V
Resolution 24 bits (including sign)
Internal Resistance Greater than 200 kOhm
Input Filter Limit Frequency 3 kHz
E-bus Current Consumption Typically 190 mA
Common-Mode Voltage (Ucm) Maximum 35 V
Crosstalk Attenuation Greater than 60 dB
Electrical Isolation 500 V (E-bus / signal voltage)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 percent, non-condensing
Protection Rating IP20
Approvals & Markings CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)
Housing Dimensions 12 mm x 100 mm x 68 mm
Net Module Weight 60 g
Shipping Weight (Calculated) 0.15 kg
Package Dimensions (Calculated) 120 mm x 80 mm x 25 mm
Country of Origin Germany

Connections and Interfaces

Terminal Point Signal Assignment (Channel 1) Terminal Point Signal Assignment (Channel 2)
1 Input + 2 Input +
5 Input - 6 Input -
3 Shield 7 Shield
4 Analog Ground (AGND) 8 Analog Ground (AGND)

Empirical Engineering Insights

Alternative Models & Compatibility

When replacing or integrating the EL3602, verify the TwinCAT software version and active EtherCAT XML Device Description (ESI) files. The EL3602 features dynamic configuration via CoE (CAN over EtherCAT) variables. Ensure that older systems designed for the calibrated alternative EL3602-0010 are checked, as scaling and calibration coefficients differ within the PLC program. When using multiple EL series modules, verify that the total E-bus current budget does not exceed the limits of the coupler or the power supply terminal; the EL3602 draws a sustained 190 mA from the E-bus.

Application Pitfalls & Engineering Notes

The common-mode voltage (Ucm) must be kept strictly below 35 V relative to the internal E-bus ground to prevent measurement errors and potential damage. Ground loops are the primary source of drift in 24-bit applications. If measuring floating voltage sources, ensure the AGND terminal is linked to a clean, stable system reference to prevent the differential inputs from drifting into saturation. Additionally, allow a 15-minute thermal stabilization period after powering the cabinet to ensure the internal reference reaches equilibrium for 24-bit resolution stability.

Commissioning & Wiring Tips

Use twisted-pair shielded cabling for all analog signals. The shield should be terminated directly at the terminal (Terminal 3 or 7) for best high-frequency performance. In high-interference environments, utilize the TwinCAT system manager to activate the 50 Hz or 60 Hz notch filter inside the module's CoE registers. This significantly attenuates electrical line noise and maintains the module's ultra-low measurement error rating.

Installation Guidelines

CRITICAL WARNING

Always isolate the power supply of the entire EtherCAT station before inserting or removing terminals. Failure to de-energize the E-bus could cause damage to the internal contact pins or result in system communication failures.

1

Align the terminal onto the 35 mm DIN rail (conforming to EN 60715) and slide it to lock into the adjoining module using the double slot and key connection.

2

Push the terminal forward until the orange locking slide snaps securely over the rail.

3

Insert a flathead screwdriver into the spring-actuated terminal openings to wire connections. Solid or stranded conductors (0.08 to 2.5 mm2, AWG 28-14) must be stripped exactly 8 to 9 mm.

4

Verify connection status using the integrated LEDs before applying full system logic power.

Loading product navigation…

What is the default conversion time of the EL3602, and can it be adjusted?

The default conversion time is 20 ms. However, it is fully parameterizable via CoE (CAN over EtherCAT) settings between 1 ms and 400 ms.

What is the maximum common-mode voltage allowed on this analog module?

The maximum common-mode voltage (Ucm) is 35 V. Exceeding this rating can lead to saturated analog signals, measurement errors, or terminal damage.

Does the EL3602 require an external power supply connection?

No, the EL3602 receives its operational power entirely from the internal E-bus connection, drawing typically 190 mA.

Can I configure the channels for single-ended voltage measurement?

The EL3602 features dedicated differential inputs. For single-ended measurements, you must connect the negative terminal to the reference ground (AGND) while verifying you do not violate the 35 V common-mode limit.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...