The BECKHOFF EL3612 is a 2-channel analog input terminal designed for high-precision current measurement within EtherCAT automation systems. Engineered with differential input technology, this terminal processes 0 to 20 mA signals with a high resolution of 24 bits, making it suitable for demanding industrial measurement and control tasks requiring strict accuracy.

System communication and internal powering are handled directly via the E-bus, integrating smoothly into modular terminal assemblies. The device features configurable conversion times, selectable input filter limit frequencies, and diagnostic capabilities, allowing engineers to adapt signal processing characteristics to specific application requirements.

Features

  • Two differential analog input channels for 0 to 20 mA current signals
  • High-precision measurement with 24-bit resolution including sign
  • Configurable conversion time ranging from 1 to 400 ms
  • Selectable input filter limit frequency up to 3 kHz
  • E-bus powered terminal design with integrated electrical isolation between channels and the E-bus
  • Compact polycarbonate housing featuring signal LEDs for operational status monitoring

Applications

  • Precision industrial process monitoring and control
  • Sensor signal acquisition in test stands and laboratory automation
  • Data logging applications requiring high measurement accuracy
  • Machine-building automation systems utilizing EtherCAT networks

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3612
Product Type EtherCAT Terminal
Number of Inputs 2 (differential)
Country of Origin Germany

Electrical

Parameter Specification
Signal Type Differential current
Signal Current 0…20 mA
Power Supply Via the E-bus
Current Consumption E-bus Typ. 190 mA
Internal Resistance Typ. 85 ohm + diode voltage
Common-Mode Voltage UCM Max. 10 V
Electrical Isolation 500 V (E-bus/signal voltage)

Performance

Parameter Specification
Resolution 24 bit (incl. sign)
Conversion Time 1…400 ms configurable
Measuring Error < ±0.01 % at 25 degC (relative to full scale value, 50 Hz filter)
Input Filter Limit Frequency 3 kHz
Crosstalk Attenuation > 60 dB

Mechanical and Environment

Parameter Specification
Design Form Compact terminal housing with signal LEDs
Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight Approx. 60 g
Mounting On 35 mm DIN rail, conforming to EN 60715 with lock
Protection Rating IP20
Operating Temperature Range -25…+60 degC
Storage Temperature Range -40…+85 degC
Relative Humidity 95 %, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Connection Technology

Parameter Specification
Connection Cross-Section Solid (s) 0.08…2.5 mm² (AWG 28…14)
Connection Cross-Section Stranded (st) 0.08…2.5 mm² (AWG 28…14)
Connection Cross-Section with Ferrule (f) 0.14…1.5 mm² (AWG 26…16)
Stripping Length 8…9 mm

Installation Guidelines

  1. Ensure the entire control system is safely powered down and isolated from electrical energy before performing any mechanical or electrical work.
  2. Inspect the BECKHOFF EL3612 terminal housing and connection points for any signs of transit damage.
  3. Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, ensuring the locking mechanism engages securely.
  4. Connect field sensors to the appropriate terminal points using solid or stranded conductors with proper stripping lengths and ferrule use where required.
  5. Verify that all signal wiring and shield connections adhere to local electrical codes and EMC requirements.
  6. Power on the EtherCAT network and verify proper diagnostic LED operation through the TwinCAT engineering environment before initiating normal system operation.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What are the primary electrical specifications and input channels of the BECKHOFF EL3612?
The BECKHOFF EL3612 is a 2-channel analog input terminal designed specifically for processing differential 0 to 20 mA current signals. It features an internal resistance of typically 85 ohms plus diode voltage and supports a maximum common-mode voltage of 10 V. The unit ensures robust operation with a 500 V electrical isolation between the E-bus and the signal voltage.
What kind of measurement precision and resolution does the BECKHOFF EL3612 offer?
The BECKHOFF EL3612 provides an exceptionally high resolution of 24 bits including the sign for precise analog measurements. It delivers a measuring error of less than ±0.01% at 25 degrees Celsius relative to the full scale value using a 50 Hz filter. Furthermore, engineers can configure the conversion time from 1 to 400 ms and utilize an input filter limit frequency of up to 3 kHz.
How is the BECKHOFF EL3612 powered and integrated into an automation network?
The BECKHOFF EL3612 draws its power directly through the E-bus with a typical current consumption of 190 mA. It integrates seamlessly into modular EtherCAT terminal assemblies and mounts easily onto standard 35 mm DIN rails conforming to EN 60715. Signal status monitoring is conveniently handled via integrated LEDs on the compact polycarbonate housing.
What are the environmental and physical limitations of the BECKHOFF EL3612 terminal?
The BECKHOFF EL3612 operates reliably in ambient temperatures ranging from -25 to +60 degrees Celsius and can be stored safely between -40 and +85 degrees Celsius. It is built within a compact IP20-rated polycarbonate enclosure measuring 12 mm by 100 mm by 68 mm with a net weight of approximately 60 grams. The device also complies with strict industrial standards for vibration, shock resistance, and EMC immunity.
Reviews

EL3612

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF EL3612 EtherCAT Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3612

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF EL3612 is a 2-channel analog input terminal designed for high-precision current measurement within EtherCAT automation systems. Engineered with differential input technology, this terminal processes 0 to 20 mA signals with a high resolution of 24 bits, making it suitable for demanding industrial measurement and control tasks requiring strict accuracy.

System communication and internal powering are handled directly via the E-bus, integrating smoothly into modular terminal assemblies. The device features configurable conversion times, selectable input filter limit frequencies, and diagnostic capabilities, allowing engineers to adapt signal processing characteristics to specific application requirements.

Features

  • Two differential analog input channels for 0 to 20 mA current signals
  • High-precision measurement with 24-bit resolution including sign
  • Configurable conversion time ranging from 1 to 400 ms
  • Selectable input filter limit frequency up to 3 kHz
  • E-bus powered terminal design with integrated electrical isolation between channels and the E-bus
  • Compact polycarbonate housing featuring signal LEDs for operational status monitoring

Applications

  • Precision industrial process monitoring and control
  • Sensor signal acquisition in test stands and laboratory automation
  • Data logging applications requiring high measurement accuracy
  • Machine-building automation systems utilizing EtherCAT networks

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3612
Product Type EtherCAT Terminal
Number of Inputs 2 (differential)
Country of Origin Germany

Electrical

Parameter Specification
Signal Type Differential current
Signal Current 0…20 mA
Power Supply Via the E-bus
Current Consumption E-bus Typ. 190 mA
Internal Resistance Typ. 85 ohm + diode voltage
Common-Mode Voltage UCM Max. 10 V
Electrical Isolation 500 V (E-bus/signal voltage)

Performance

Parameter Specification
Resolution 24 bit (incl. sign)
Conversion Time 1…400 ms configurable
Measuring Error < ±0.01 % at 25 degC (relative to full scale value, 50 Hz filter)
Input Filter Limit Frequency 3 kHz
Crosstalk Attenuation > 60 dB

Mechanical and Environment

Parameter Specification
Design Form Compact terminal housing with signal LEDs
Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight Approx. 60 g
Mounting On 35 mm DIN rail, conforming to EN 60715 with lock
Protection Rating IP20
Operating Temperature Range -25…+60 degC
Storage Temperature Range -40…+85 degC
Relative Humidity 95 %, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Connection Technology

Parameter Specification
Connection Cross-Section Solid (s) 0.08…2.5 mm² (AWG 28…14)
Connection Cross-Section Stranded (st) 0.08…2.5 mm² (AWG 28…14)
Connection Cross-Section with Ferrule (f) 0.14…1.5 mm² (AWG 26…16)
Stripping Length 8…9 mm

Installation Guidelines

  1. Ensure the entire control system is safely powered down and isolated from electrical energy before performing any mechanical or electrical work.
  2. Inspect the BECKHOFF EL3612 terminal housing and connection points for any signs of transit damage.
  3. Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, ensuring the locking mechanism engages securely.
  4. Connect field sensors to the appropriate terminal points using solid or stranded conductors with proper stripping lengths and ferrule use where required.
  5. Verify that all signal wiring and shield connections adhere to local electrical codes and EMC requirements.
  6. Power on the EtherCAT network and verify proper diagnostic LED operation through the TwinCAT engineering environment before initiating normal system operation.
Loading product navigation…
Key Features:

What are the primary electrical specifications and input channels of the BECKHOFF EL3612?

The BECKHOFF EL3612 is a 2-channel analog input terminal designed specifically for processing differential 0 to 20 mA current signals. It features an internal resistance of typically 85 ohms plus diode voltage and supports a maximum common-mode voltage of 10 V. The unit ensures robust operation with a 500 V electrical isolation between the E-bus and the signal voltage.

What kind of measurement precision and resolution does the BECKHOFF EL3612 offer?

The BECKHOFF EL3612 provides an exceptionally high resolution of 24 bits including the sign for precise analog measurements. It delivers a measuring error of less than ±0.01% at 25 degrees Celsius relative to the full scale value using a 50 Hz filter. Furthermore, engineers can configure the conversion time from 1 to 400 ms and utilize an input filter limit frequency of up to 3 kHz.

How is the BECKHOFF EL3612 powered and integrated into an automation network?

The BECKHOFF EL3612 draws its power directly through the E-bus with a typical current consumption of 190 mA. It integrates seamlessly into modular EtherCAT terminal assemblies and mounts easily onto standard 35 mm DIN rails conforming to EN 60715. Signal status monitoring is conveniently handled via integrated LEDs on the compact polycarbonate housing.

What are the environmental and physical limitations of the BECKHOFF EL3612 terminal?

The BECKHOFF EL3612 operates reliably in ambient temperatures ranging from -25 to +60 degrees Celsius and can be stored safely between -40 and +85 degrees Celsius. It is built within a compact IP20-rated polycarbonate enclosure measuring 12 mm by 100 mm by 68 mm with a net weight of approximately 60 grams. The device also complies with strict industrial standards for vibration, shock resistance, and EMC immunity.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.