BECKHOFF

BECKHOFF EL3702 EtherCAT Terminal

SKU EL3702

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EL3702
  • Origin Germany
  • Product Type: EtherCAT Terminals
  • Payment: T/T, Western Union
  • Weight: 0.06 kg
  • Dimensions: 12 mm x 100 mm x 68 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF EL3702 is a high-performance 2-channel analog input terminal designed for high-speed, high-precision voltage measurements. Operating within the modular EtherCAT I/O system, this terminal supports differential signal acquisition in the range of -10 to +10 V with 16-bit resolution. It is engineered specifically for dynamic measurement tasks requiring synchronous, high-frequency data collection across distributed control systems.

A key capability of the BECKHOFF EL3702 is its support for oversampling technology. This allows the terminal to sample analog input values at rates far higher than the master control cycle time. By utilizing EtherCAT Distributed Clocks (DC), the acquired measurements are precisely timestamped and synchronized across the network with sub-microsecond precision, making it an excellent choice for detailed signal analysis and transient state monitoring.

Features

  • Two differential analog input channels designed for ±10 V voltage signals.
  • Oversampling technology with a selectable factor (n = 1 to 100) for custom data acquisition profiles.
  • Maximum sampling rate of 10 microseconds (100 ksamples/s) per channel, executed simultaneously.
  • 16-bit analog-to-digital conversion resolution (including sign) for high-fidelity signal reconstruction.
  • Integrated Distributed Clocks (DC) support, delivering synchronization precision of less than 1 microsecond.
  • 500 V electrical isolation between the E-bus logic and the incoming signal voltage.
  • Compact 12 mm housing with status LEDs indicating operational and diagnostic states.

Applications

  • High-speed transient signal and wave recording.
  • Vibration analysis, acoustic measurement, and structural health monitoring.
  • Dynamic force, pressure, or torque monitoring in test benches.
  • Fast closed-loop control systems where low-latency feedback is critical.
  • Quality control systems requiring high-frequency sensor signal analysis.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model EL3702
Product Type EtherCAT Terminal
Design Form Compact terminal housing with signal LEDs
Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Installation 35 mm DIN rail (EN 60715) with locking mechanism
Weight Approx. 60 g

Signal and I/O

Parameter Specification
Number of Inputs 2 (differential)
Signal Type Differential voltage
Signal Voltage Range -10 V to +10 V
Internal Resistance > 200 kOhm
Input Filter Limit Frequency 80 kHz
Recommended Input Bandwidth 0 to 30 kHz
Common-Mode Voltage (UCM) Max. 35 V

Electrical

Parameter Specification
Power Supply Via the E-bus
Current Consumption (E-bus) Typ. 200 mA
Current Load Power Contacts Max. 10 A
Electrical Isolation 500 V (E-bus / signal voltage)

Performance and Synchronization

Parameter Specification
Conversion Time ~ 10 microseconds per sample
Resolution 16 bit (including sign)
Maximum Sampling Rate 10 microseconds / 100 ksps per channel, simultaneous
Oversampling Factor (n) 1 to 100 (selectable)
Measuring Error (up to 10 Hz) < ±0.3% (relative to full scale value)
Distributed Clocks (DC) Yes
Distributed Clock Precision << 1 microsecond
Process Image Width Input: n x 2 x 16 bit data; optional 2 x 16 bit cycle counter, 4 byte StartNextLatch time

Connection

Parameter Specification
Wiring Technology Spring actuation by screwdriver
Conductor Cross-Section (Solid/Stranded) 0.08 to 2.5 mm² (AWG 28 to 14)
Conductor Cross-Section (With Ferrule) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Environmental and Safety

Parameter Specification
Operating Temperature -25 to +60 Celsius
Storage Temperature -40 to +85 Celsius
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Approvals and Markings CE, UL, ATEX, IECEx, cFMus

Installation Guidelines

  1. De-energize the System: Always disconnect the power supply to the entire bus terminal block before inserting, removing, or wiring any module.
  2. DIN Rail Mounting: Slide the EL3702 terminal onto a standard 35 mm DIN rail (EN 60715) until the lock clicks securely into place.
  3. Terminal Connection: Ensure the terminal is pushed flush against adjacent modules to guarantee reliable contact for the E-bus and potential connections.
  4. Wiring: Insert a suitable screwdriver into the release slot to open the spring clamp, feed the stripped conductor (8 to 9 mm) into the contact point, and release. Use shielded cables for analog signals to minimize electromagnetic interference.
  5. Configuration: Scan the terminal in the TwinCAT System Manager, select the required oversampling factor, and link the resulting process image variables to your control application.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the main function of the BECKHOFF EL3702?
The BECKHOFF EL3702 is a 2-channel analog input EtherCAT Terminal designed for high-speed acquisition of voltage signals in the range of ±10 V using differential input technology and oversampling capabilities.
What is the maximum sampling rate of the BECKHOFF EL3702?
The BECKHOFF EL3702 supports a maximum sampling rate of 10 microseconds (100 ksamples/s) per channel simultaneously, depending on the chosen oversampling factor.
How does oversampling work on the BECKHOFF EL3702?
The BECKHOFF EL3702 registers multiple analog measurements within a single PLC cycle (using an oversampling factor of 1 to 100) and transmits them in a structured packet back to the controller via EtherCAT.
Does the BECKHOFF EL3702 support Distributed Clocks (DC)?
Yes, the BECKHOFF EL3702 supports EtherCAT Distributed Clocks (DC), enabling synchronization precision of significantly less than 1 microsecond across all networked nodes.
What are the power requirements for the BECKHOFF EL3702?
The BECKHOFF EL3702 is powered directly from the E-bus backplane with a typical current consumption of 200 mA; it does not draw current from the external field-side power contacts.
Reviews

EL3702

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF EL3702 EtherCAT Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3702

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 60g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF EL3702 is a high-performance 2-channel analog input terminal designed for high-speed, high-precision voltage measurements. Operating within the modular EtherCAT I/O system, this terminal supports differential signal acquisition in the range of -10 to +10 V with 16-bit resolution. It is engineered specifically for dynamic measurement tasks requiring synchronous, high-frequency data collection across distributed control systems.

A key capability of the BECKHOFF EL3702 is its support for oversampling technology. This allows the terminal to sample analog input values at rates far higher than the master control cycle time. By utilizing EtherCAT Distributed Clocks (DC), the acquired measurements are precisely timestamped and synchronized across the network with sub-microsecond precision, making it an excellent choice for detailed signal analysis and transient state monitoring.

Features

  • Two differential analog input channels designed for ±10 V voltage signals.
  • Oversampling technology with a selectable factor (n = 1 to 100) for custom data acquisition profiles.
  • Maximum sampling rate of 10 microseconds (100 ksamples/s) per channel, executed simultaneously.
  • 16-bit analog-to-digital conversion resolution (including sign) for high-fidelity signal reconstruction.
  • Integrated Distributed Clocks (DC) support, delivering synchronization precision of less than 1 microsecond.
  • 500 V electrical isolation between the E-bus logic and the incoming signal voltage.
  • Compact 12 mm housing with status LEDs indicating operational and diagnostic states.

Applications

  • High-speed transient signal and wave recording.
  • Vibration analysis, acoustic measurement, and structural health monitoring.
  • Dynamic force, pressure, or torque monitoring in test benches.
  • Fast closed-loop control systems where low-latency feedback is critical.
  • Quality control systems requiring high-frequency sensor signal analysis.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model EL3702
Product Type EtherCAT Terminal
Design Form Compact terminal housing with signal LEDs
Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Installation 35 mm DIN rail (EN 60715) with locking mechanism
Weight Approx. 60 g

Signal and I/O

Parameter Specification
Number of Inputs 2 (differential)
Signal Type Differential voltage
Signal Voltage Range -10 V to +10 V
Internal Resistance > 200 kOhm
Input Filter Limit Frequency 80 kHz
Recommended Input Bandwidth 0 to 30 kHz
Common-Mode Voltage (UCM) Max. 35 V

Electrical

Parameter Specification
Power Supply Via the E-bus
Current Consumption (E-bus) Typ. 200 mA
Current Load Power Contacts Max. 10 A
Electrical Isolation 500 V (E-bus / signal voltage)

Performance and Synchronization

Parameter Specification
Conversion Time ~ 10 microseconds per sample
Resolution 16 bit (including sign)
Maximum Sampling Rate 10 microseconds / 100 ksps per channel, simultaneous
Oversampling Factor (n) 1 to 100 (selectable)
Measuring Error (up to 10 Hz) < ±0.3% (relative to full scale value)
Distributed Clocks (DC) Yes
Distributed Clock Precision << 1 microsecond
Process Image Width Input: n x 2 x 16 bit data; optional 2 x 16 bit cycle counter, 4 byte StartNextLatch time

Connection

Parameter Specification
Wiring Technology Spring actuation by screwdriver
Conductor Cross-Section (Solid/Stranded) 0.08 to 2.5 mm² (AWG 28 to 14)
Conductor Cross-Section (With Ferrule) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Environmental and Safety

Parameter Specification
Operating Temperature -25 to +60 Celsius
Storage Temperature -40 to +85 Celsius
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Approvals and Markings CE, UL, ATEX, IECEx, cFMus

Installation Guidelines

  1. De-energize the System: Always disconnect the power supply to the entire bus terminal block before inserting, removing, or wiring any module.
  2. DIN Rail Mounting: Slide the EL3702 terminal onto a standard 35 mm DIN rail (EN 60715) until the lock clicks securely into place.
  3. Terminal Connection: Ensure the terminal is pushed flush against adjacent modules to guarantee reliable contact for the E-bus and potential connections.
  4. Wiring: Insert a suitable screwdriver into the release slot to open the spring clamp, feed the stripped conductor (8 to 9 mm) into the contact point, and release. Use shielded cables for analog signals to minimize electromagnetic interference.
  5. Configuration: Scan the terminal in the TwinCAT System Manager, select the required oversampling factor, and link the resulting process image variables to your control application.
Loading product navigation…

What is the main function of the BECKHOFF EL3702?

The BECKHOFF EL3702 is a 2-channel analog input EtherCAT Terminal designed for high-speed acquisition of voltage signals in the range of ±10 V using differential input technology and oversampling capabilities.

What is the maximum sampling rate of the BECKHOFF EL3702?

The BECKHOFF EL3702 supports a maximum sampling rate of 10 microseconds (100 ksamples/s) per channel simultaneously, depending on the chosen oversampling factor.

How does oversampling work on the BECKHOFF EL3702?

The BECKHOFF EL3702 registers multiple analog measurements within a single PLC cycle (using an oversampling factor of 1 to 100) and transmits them in a structured packet back to the controller via EtherCAT.

Does the BECKHOFF EL3702 support Distributed Clocks (DC)?

Yes, the BECKHOFF EL3702 supports EtherCAT Distributed Clocks (DC), enabling synchronization precision of significantly less than 1 microsecond across all networked nodes.

What are the power requirements for the BECKHOFF EL3702?

The BECKHOFF EL3702 is powered directly from the E-bus backplane with a typical current consumption of 200 mA; it does not draw current from the external field-side power contacts.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...