BECKHOFF

BECKHOFF EL3692 EtherCAT Terminal

SKU EL3692

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: EL3692

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 55g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for high-precision resistance measurements, the Beckhoff EL3692 is a 2-channel analog input EtherCAT Terminal capable of reading values from 100 mΩ up to 10 MΩ. It features a high-resolution 24-bit analog-to-digital converter and supports both 2-wire and 4-wire connection configurations to eliminate lead wire resistance errors. Integrating seamlessly into standard EtherCAT networks, this module provides fast, reliable, and highly stable data acquisition for industrial sensors, potentiometers, and variable resistance devices.

The EL3692 dynamically manages measuring ranges through automatic range selection or direct PLC controller configuration. Additionally, it provides built-in wiring failure detection to alert systems of open circuits, ensuring maximum operational safety and diagnostics in critical process control applications.

Features

  • Two high-resolution (24-bit) analog input channels dedicated to resistance measurements.
  • Broad measuring span from 100 mΩ up to 10 MΩ.
  • Flexible technology supporting both 2-wire and 4-wire connection methods.
  • Automatic or controller-driven range switching.
  • Pulse and continuous measurement modes for minimized power dissipation and self-heating.
  • Integrated wire failure diagnostics.
  • Galvanic isolation of 1500 V between the E-bus and the field potential.
  • Compact 12 mm terminal housing designed for efficient space utilization on DIN rails.

Applications

  • Precision RTD and temperature sensor monitoring.
  • Industrial testing benches and quality control systems.
  • Strain gauge and potentiometer monitoring in manufacturing environments.
  • Heavy duty automation systems requiring precise resistance tracking.

Technical Specifications

Manufacturer BECKHOFF
Model / Part Number EL3692
Number of Inputs 2
Power Supply Via the E-bus
Technology 2-wire or 4-wire resistance measurement
Signal Type Single-ended
Measuring Ranges 100 mΩ, 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ
Resolution 24 bit
Measuring Error < ±0.5% (relative to full scale value with 4-wire connection)
Internal Resistance > 100 MΩ
Input Filter Limit Frequency 100 Hz
Conversion Time Typically 10 to 400 ms (dependent on measuring range and settings)
E-bus Current Consumption Typically 220 mA
Electrical Isolation 1500 V (E-bus / field potential)
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 55 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
IP Rating IP20
Material Polycarbonate

Connections and Interfaces

Connection Type Conductor Cross-section AWG Range
Solid Wire (s) 0.08 to 2.5 mm² AWG 28 to 14
Stranded Wire (st) 0.08 to 2.5 mm² AWG 28 to 14
Flexible Conductor with Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16
Stripping Length 8 to 9 mm -

Installation Guidelines

  • Mount vertically or horizontally on a standard 35 mm DIN rail (conforming to EN 60715) using the integrated locking mechanism.
  • Ensure secure side-by-side terminal contact using the built-in double slot and key connection system.
  • Maintain clear ventilation around the terminal to preserve the ambient operating temperature between 0 and +55 degC.
  • For hazardous area installations, adhere to the certified ATEX guidelines under Ex classification II 3 G Ex nA IIC T4 Gc.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

FAQ

What is the measuring range of the Beckhoff EL3692?

The EL3692 supports a wide resistance measuring range from 100 mΩ up to 10 MΩ across several sub-ranges.

Does the EL3692 require an external power supply?

No, the EL3692 is powered directly via the internal E-bus of the EtherCAT Terminal system.

What connection technologies are supported by the EL3692?

The terminal supports both 2-wire and 4-wire resistance measurement technologies for flexible sensor connection.

What is the resolution of this analog input terminal?

The EL3692 offers a high-precision 24-bit resolution.

What hazardous area certifications does the module hold?

The EL3692 is ATEX certified with the marking II 3 G Ex nA IIC T4 Gc for Zone 2 applications.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.