Product Overview

The EL4002 (EL4002) is a high-precision, 2-channel analog output terminal from the Beckhoff EL series, designed for industrial control applications requiring precise voltage signals. Operating within the 0 to 10 V range with 12-bit resolution, this terminal facilitates reliable communication between the EtherCAT network and peripheral actuators such as proportional valves, frequency converters, or heating control elements. With support for Distributed Clocks (DC) and a sub-microsecond precision, the EL4002 ensures deterministic control performance, which is vital for high-speed synchronization in multi-axis motion and complex process control systems, ultimately reducing signal latency and enhancing overall system stability.

Technical Configuration

The EL4002 utilizes a 2-wire, single-ended connection architecture, optimized for stable 0 to 10 V voltage output with a load capability exceeding 5 kOhm. The module is fully integrated into the EtherCAT E-bus, providing electrical isolation up to 500 V between the field potential and the internal communication bus. A standout feature of the EL4002 is its user-configurable watchdog and synchronization capabilities; these allow engineers to define safe-state output values during network interruptions, including ramp-based transitions to prevent sudden mechanical movements, thereby safeguarding equipment and personnel.

Technical Specifications

Feature Specification
Model EL4002
Brand BECKHOFF
Origin Germany
Number of Outputs 2
Signal Voltage 0 to 10 V
Resolution 12 bit
Conversion Time 150 µs
Output Error < 0.1 %
Load > 5 kΩ
Operating Temperature -25 to 60 deg C
Protection Rating IP20

FAQs

How does the Distributed Clock (DC) feature benefit the application?

The Distributed Clock feature allows the terminal to synchronize its output conversion with the EtherCAT master's system time. With a precision of significantly less than 1 µs, it ensures that analog signals change exactly when required, eliminating timing jitter in the process.

What is the purpose of the watchdog feature in this terminal?

The watchdog is a safety function that monitors the EtherCAT communication link. If communication is lost, the terminal automatically switches the outputs to a pre-defined safe state, which can be configured as a fixed value or a ramped sequence to avoid dangerous machine behavior.

Can I use the EL4002 for inductive loads?

The terminal is designed for voltage output signals (0...10 V) with a load requirement > 5 kΩ. It is not intended to drive high-current inductive actuators directly. If driving such devices, ensure the input impedance of the secondary device meets the terminal's load requirements or use an intermediate signal converter.

Installation and Operational Recommendations

  • Signal Integrity: Given the 12-bit resolution, maintain high signal integrity by using shielded, twisted-pair cabling for all analog output connections. Terminate the shield at the cabinet's grounding busbar to minimize noise pickup from surrounding power cables.
  • Wiring Technique: Utilize the spring-actuation terminals with an appropriate screwdriver. When using flexible conductors, ferrules are highly recommended to prevent strand splaying, which can cause intermittent contact resistance and signal drift.
  • Side-by-Side Mounting: The EL4002 supports side-by-side mounting using a double slot and key connection. When placing multiple analog modules together, be mindful of heat dissipation; although the current consumption is low (typ. 140 mA E-bus), maintaining a consistent operating environment ensures the long-term accuracy of the output stages.
Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...