Description

Designed for highly precise industrial signal processing, the BECKHOFF EL4114 analog output terminal generates analog control currents in the 0 to 20 mA range. This 4-channel output module features a high 16-bit resolution, delivering accurate control variables directly to field devices such as proportional valves, variable speed drives, and process indicators. Integrating natively into the EtherCAT high-speed communication network, the terminal supports Distributed Clocks (DC) to achieve synchronization precision of less than 1 microsecond, making it ideal for highly synchronized multi-axis control loops and demanding automation processes.

The compact 12 mm housing includes diagnostic LEDs indicating active status and communication states. The EL4114 utilizes 2-wire, single-ended connection technology, allowing for clean, space-saving cabinet layouts. Integrated parameterizable watchdog timers ensure safe fall-back states in the event of a control bus interruption.

Features

  • Four analog output channels processing standard 0 to 20 mA signals.
  • High-resolution 16-bit digital-to-analog conversion for fine control increments.
  • EtherCAT Distributed Clocks (DC) support with precision under 1 µs.
  • 2-wire, single-ended wiring configuration.
  • Short-circuit proof outputs with a maximum load capacity of 350 ohms.
  • Configurable watchdog parameters for safety during communication faults.
  • Robust electrical isolation of 500 V between the internal E-bus and signal channels.

Applications

  • Proportional valve control and actuator positioning.
  • Speed referencing for variable frequency drives (VFDs) and motor controllers.
  • Analog signal transmission to remote recorders or data acquisition units.
  • Process loop control in oil & gas, water treatment, and power generation.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL4114
Number of Outputs 4
Signal Current 0 to 20 mA
Resolution 16 bit (including sign)
Connection Technology 2-wire, single-ended
Power Supply 24 V DC via power contacts
Distributed Clocks Yes (precision < 1 µs)
Load Resistance < 350 Ohm (short-circuit proof)
Output Error < 0.1% (relative to end value)
Output Rate Max. 4 ksps
Electrical Isolation 500 V (E-bus / signal voltage)
Current Consumption Power Contacts Typ. 15 mA + load
Current Consumption E-bus Typ. 160 mA
Process Image Bit Width 4 x 16 bit AO output
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 65 g

Connections and Interfaces

Conductor Type Cross-section Range AWG Range
Solid Conductor (e) 0.08 to 2.5 mm² AWG 28 to 14
Stranded Conductor (st) 0.08 to 2.5 mm² AWG 28 to 14
Flexible Conductor with Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16

Note: Stripping length for terminals is 8 to 9 mm. Wire release via spring-actuated mechanism using a standard screwdriver.

Installation Guidelines

  • Mount vertically on standard 35 mm DIN rails conforming to EN 60715 using the integrated locking mechanism.
  • Ensure secure side-by-side connection using the built-in double slot and key system on the terminal housing.
  • An IP20 rated enclosure must be utilized to safeguard against environmental contaminants and conductive dust.
  • Avoid routing sensitive analog signal lines parallel to high-voltage power cables to minimize EMI coupling.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

FAQ

What is the primary function of the Beckhoff EL4114?

The Beckhoff EL4114 is a 4-channel analog output terminal designed to convert digital values from the controller into analog current signals ranging from 0 to 20 mA with 16-bit resolution.

Does the EL4114 support Distributed Clocks (DC)?

Yes, the EL4114 supports Distributed Clocks, allowing for highly synchronized output updates with a time precision of less than 1 microsecond across the EtherCAT system.

What are the wiring specifications for the EL4114's connection terminals?

The terminal uses a spring-actuated push-in mechanism. It accepts solid and stranded conductors from 0.08 to 2.5 mm² (AWG 28-14) and flexible conductors with ferrules from 0.14 to 1.5 mm² (AWG 26-16) with a stripping length of 8 to 9 mm.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...