To analyze three-phase AC power networks directly within the industrial fieldbus segment, the Beckhoff EL3403 provides precise, high-performance measurement values. This 3-channel analog input power measurement terminal is designed to calculate comprehensive electrical grid status parameters, including effective power, reactive power, apparent power, energy consumption, phase angle (cos phi), and frequency for each connected phase. Processing inputs up to 500 V AC directly, the module supports highly detailed diagnostics of energy distribution systems and industrial machinery. Non-intrusive current sensing up to 1 A (AC) is executed through external measuring transformers (such as x A/1 A), enabling flexible integration into existing power distribution frameworks.

Features

  • Mains-synchronous conversion with 16-bit resolution for premium signal acquisition.
  • Direct RMS value calculation for all applied voltage and current waveforms.
  • Comprehensive data calculation: delivers current, voltage, active/reactive/apparent power, energy, frequency, and phase angle values directly over the E-bus.
  • Optional single-phase operation mode for simplified monitoring on isolated lines.
  • Galvanic electrical isolation rating of 1500 V to isolate low-voltage logic from high-voltage measuring points.
  • Compact 12 mm design form factor optimizing space layout on industrial DIN rails.

Applications

  • Real-time energy management and sub-metering in industrial production facilities.
  • Dynamic load monitoring and diagnostic tracking on high-power three-phase AC motors.
  • Integration within power distribution plants and substation cabinets for utility tracking.
  • Predictive maintenance analytics based on power signature variations.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL3403
Technology 3-phase power measurement for alternating voltages
Number of Inputs 3 x current, 3 x voltage
Measuring Voltage Max. 500 V AC 3~ (ULX-N: max. 288 V AC)
Measuring Current Max. 1 A AC (via measuring transformers x A/1 A)
Resolution 1 uA, 0.1 mV, 10 mW (16-bit)
Measuring Error 0.5% relative to full scale value (U/I), 1% calculated values
Measuring Procedure True RMS calculation
Conversion Time Mains-synchronous
Electrical Isolation 1500 V
Current Consumption E-bus Typ. 120 mA
Process Image Bit Width 62 byte PM input, 3 byte PM output
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Enclosure Protection Rating IP20
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 75 g

Connections and Interfaces

Connection Property Specification
Wiring Method Solid conductor (e), flexible conductor (f), and ferrule (a)
Actuation Method Spring actuation by screwdriver
Connection Cross-Section (Solid/Stranded) 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section (With Ferrule) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm
Current Load Power Contacts Max. 10 A

Installation Guidelines

  • Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, locking it firmly into place.
  • Ensure double slot and key mechanical connection is completely flush with adjacent terminals.
  • Route high-voltage measurement lines separated from low-voltage E-bus and signal lines to prevent noise coupling.
  • Install appropriate external current transformer shorting blocks for safety during troubleshooting or hardware swap-outs.

Compliance and Certifications

  • CE
  • UL listed
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What parameters can the Beckhoff EL3403 calculate and display?
The EL3403 measures voltage, current, effective power, reactive power, apparent power, energy consumption, phase angle (cos phi), and frequency for each of the three channels.
Does the EL3403 support single-phase operation?
Yes, while the terminal is optimized for 3-phase power measurement on AC networks, it also supports optional single-phase configuration.
What is the maximum voltage input direct rating of the EL3403?
The terminal is rated for a maximum measuring voltage of 500 V AC 3-phase (with ULX-N rating at a maximum of 288 V AC).
How is the current measured using this EtherCAT terminal?
The module measures AC current up to 1 A, which is typically routed via external, standard measuring transformers configured as x A / 1 A.
What is the mechanical environmental protection rating of the EL3403?
The terminal has an IP20 protection rating and is designed for cabinet installation on a 35 mm DIN rail.
Reviews

EL3403

Stock & lead time on request

Call
1 of 1

BECKHOFF EL3403 EtherCAT Terminal 3-Channel Power Measurement Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3403

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 75g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

To analyze three-phase AC power networks directly within the industrial fieldbus segment, the Beckhoff EL3403 provides precise, high-performance measurement values. This 3-channel analog input power measurement terminal is designed to calculate comprehensive electrical grid status parameters, including effective power, reactive power, apparent power, energy consumption, phase angle (cos phi), and frequency for each connected phase. Processing inputs up to 500 V AC directly, the module supports highly detailed diagnostics of energy distribution systems and industrial machinery. Non-intrusive current sensing up to 1 A (AC) is executed through external measuring transformers (such as x A/1 A), enabling flexible integration into existing power distribution frameworks.

Features

  • Mains-synchronous conversion with 16-bit resolution for premium signal acquisition.
  • Direct RMS value calculation for all applied voltage and current waveforms.
  • Comprehensive data calculation: delivers current, voltage, active/reactive/apparent power, energy, frequency, and phase angle values directly over the E-bus.
  • Optional single-phase operation mode for simplified monitoring on isolated lines.
  • Galvanic electrical isolation rating of 1500 V to isolate low-voltage logic from high-voltage measuring points.
  • Compact 12 mm design form factor optimizing space layout on industrial DIN rails.

Applications

  • Real-time energy management and sub-metering in industrial production facilities.
  • Dynamic load monitoring and diagnostic tracking on high-power three-phase AC motors.
  • Integration within power distribution plants and substation cabinets for utility tracking.
  • Predictive maintenance analytics based on power signature variations.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL3403
Technology 3-phase power measurement for alternating voltages
Number of Inputs 3 x current, 3 x voltage
Measuring Voltage Max. 500 V AC 3~ (ULX-N: max. 288 V AC)
Measuring Current Max. 1 A AC (via measuring transformers x A/1 A)
Resolution 1 uA, 0.1 mV, 10 mW (16-bit)
Measuring Error 0.5% relative to full scale value (U/I), 1% calculated values
Measuring Procedure True RMS calculation
Conversion Time Mains-synchronous
Electrical Isolation 1500 V
Current Consumption E-bus Typ. 120 mA
Process Image Bit Width 62 byte PM input, 3 byte PM output
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Enclosure Protection Rating IP20
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 75 g

Connections and Interfaces

Connection Property Specification
Wiring Method Solid conductor (e), flexible conductor (f), and ferrule (a)
Actuation Method Spring actuation by screwdriver
Connection Cross-Section (Solid/Stranded) 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section (With Ferrule) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm
Current Load Power Contacts Max. 10 A

Installation Guidelines

  • Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, locking it firmly into place.
  • Ensure double slot and key mechanical connection is completely flush with adjacent terminals.
  • Route high-voltage measurement lines separated from low-voltage E-bus and signal lines to prevent noise coupling.
  • Install appropriate external current transformer shorting blocks for safety during troubleshooting or hardware swap-outs.

Compliance and Certifications

  • CE
  • UL listed
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27

What parameters can the Beckhoff EL3403 calculate and display?

The EL3403 measures voltage, current, effective power, reactive power, apparent power, energy consumption, phase angle (cos phi), and frequency for each of the three channels.

Does the EL3403 support single-phase operation?

Yes, while the terminal is optimized for 3-phase power measurement on AC networks, it also supports optional single-phase configuration.

What is the maximum voltage input direct rating of the EL3403?

The terminal is rated for a maximum measuring voltage of 500 V AC 3-phase (with ULX-N rating at a maximum of 288 V AC).

How is the current measured using this EtherCAT terminal?

The module measures AC current up to 1 A, which is typically routed via external, standard measuring transformers configured as x A / 1 A.

What is the mechanical environmental protection rating of the EL3403?

The terminal has an IP20 protection rating and is designed for cabinet installation on a 35 mm DIN rail.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...