The BECKHOFF EL9184 is a potential distribution terminal designed for space-saving potential routing directly within an EtherCAT Terminal segment. Operating as a passive terminal, this module provides 16 connection points in a compact 12 mm High Density (HD) housing, making it an efficient alternative to traditional external terminal blocks.

By accessing the internal power contacts of the adjacent EtherCAT Terminals, the BECKHOFF EL9184 distributes 8 potential points of 24 V DC and 8 potential points of 0 V DC. This configuration enables direct, neat, and organized wiring for multiple sensors, actuators, and control devices without consuming unnecessary DIN rail space.

Equipped with advanced connection technology, this potential distribution terminal simplifies wiring tasks during assembly and maintenance. Its passive architecture ensures it does not require process image data or E-bus current to function, serving purely to optimize field-side power distribution.

Features

  • Provides 16 potential distribution points: 8 x 24 V DC and 8 x 0 V DC.
  • 12 mm High Density (HD) housing optimizes cabinet space requirements.
  • Direct plug-in (push-in) connection technology for toolless solid wire installation.
  • Spring-actuated terminals for easy connection of stranded wires and ferrules.
  • Passive system design with 0-bit process image width.
  • Ensures clean wiring layout by eliminating external distribution strips.
  • Integrated potential distribution derived directly from the power contacts.

Applications

  • Field-side power distribution for multi-sensor and multi-actuator configurations.
  • Decentralized control systems requiring local 24 V DC and 0 V DC division.
  • Space-constrained electrical control cabinets and DIN rail assemblies.
  • Industrial machinery using high-density I/O configurations.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL9184
Product Type Potential distribution terminal
Housing Type HD (High Density) housing
Housing Width 12 mm
Housing Material Polycarbonate

Electrical

Parameter Specification
Nominal Voltage Max. 60 V DC
Current Load per Power Contact Max. 10 A
E-Bus Current Consumption 0 mA (passive)
Electrical Isolation 500 V (E-bus / field potential)
Bit Width in Process Image 0

Connection and Wiring

Parameter Specification
Connection Technology Direct plug-in (push-in technique)
Number of Connection Points 16 (8 x 24 V, 8 x 0 V)
Solid Wire Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Stranded Wire Cross-Section 0.25 to 1.5 mm² (AWG 22 to 16)
Ferrule Cross-Section 0.14 to 0.75 mm² (AWG 26 to 19)
Stripping Length 8 to 9 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 60 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Installation 35 mm DIN rail (conforming to EN 60715)
Side-by-Side Mounting Connection Double slot and key connection

Connections / Interfaces

Terminal Points Function
1 to 8 24 V DC distribution points (internal power contact connection)
9 to 16 0 V DC distribution points (internal power contact connection)

Installation Guidelines

  1. Ensure the entire control system and the specific terminal segment are fully de-energized before beginning installation or maintenance.
  2. Mount the BECKHOFF EL9184 onto a standard 35 mm DIN rail by snapping it into place until the locking mechanism engages.
  3. Ensure correct side-by-side positioning with adjacent EtherCAT Terminals to allow the internal power contacts to align and interface properly.
  4. For solid conductors, insert the wire directly into the connection point. For stranded or ferruled conductors, actuate the spring mechanism using a suitable screwdriver before inserting the wire.
  5. Check that the total current load across the distributed power contacts does not exceed the maximum rated limit of 10 A.

Compliance and Certifications

Certification Type Details
CE Compliant
UL cULus approved
ATEX Ex Marking II 3 G Ex nA IIC T4 Gc
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF EL9184?
The BECKHOFF EL9184 is a potential distribution terminal designed to distribute 24 V DC and 0 V DC potentials directly from adjacent power contacts to 16 individual connection points, saving wiring and DIN rail space.
Does the BECKHOFF EL9184 consume E-bus current?
No, the BECKHOFF EL9184 is a passive module and has an E-bus current consumption of 0 mA, meaning it does not load the E-bus power supply.
What types of wires can be used with the BECKHOFF EL9184?
The BECKHOFF EL9184 accepts solid wires from 0.08 to 1.5 mm² (AWG 28–16) using toolless direct plug-in insertion, as well as stranded wires (0.25 to 1.5 mm²) and wires with ferrules (0.14 to 0.75 mm²) via spring-actuation.
What is the maximum current rating for the BECKHOFF EL9184?
The BECKHOFF EL9184 supports a maximum current load of 10 A across its power contacts, with a nominal operating voltage rating of up to 60 V DC.
Does the BECKHOFF EL9184 require software configuration in TwinCAT?
No, the BECKHOFF EL9184 has a 0-bit process image width and acts purely as a passive physical routing system, so it does not require software configuration or mapping in TwinCAT.
Reviews

EL9184

Stock & lead time on request

Call
1 of 1

BECKHOFF EL9184 EtherCAT Terminal Potential Distribution Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL9184

  • Country of origin:Germany

  • Product Type: Potential Distribution Terminals

  • Payment: T/T, Western Union

  • Weight: 60g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF EL9184 is a potential distribution terminal designed for space-saving potential routing directly within an EtherCAT Terminal segment. Operating as a passive terminal, this module provides 16 connection points in a compact 12 mm High Density (HD) housing, making it an efficient alternative to traditional external terminal blocks.

By accessing the internal power contacts of the adjacent EtherCAT Terminals, the BECKHOFF EL9184 distributes 8 potential points of 24 V DC and 8 potential points of 0 V DC. This configuration enables direct, neat, and organized wiring for multiple sensors, actuators, and control devices without consuming unnecessary DIN rail space.

Equipped with advanced connection technology, this potential distribution terminal simplifies wiring tasks during assembly and maintenance. Its passive architecture ensures it does not require process image data or E-bus current to function, serving purely to optimize field-side power distribution.

Features

  • Provides 16 potential distribution points: 8 x 24 V DC and 8 x 0 V DC.
  • 12 mm High Density (HD) housing optimizes cabinet space requirements.
  • Direct plug-in (push-in) connection technology for toolless solid wire installation.
  • Spring-actuated terminals for easy connection of stranded wires and ferrules.
  • Passive system design with 0-bit process image width.
  • Ensures clean wiring layout by eliminating external distribution strips.
  • Integrated potential distribution derived directly from the power contacts.

Applications

  • Field-side power distribution for multi-sensor and multi-actuator configurations.
  • Decentralized control systems requiring local 24 V DC and 0 V DC division.
  • Space-constrained electrical control cabinets and DIN rail assemblies.
  • Industrial machinery using high-density I/O configurations.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL9184
Product Type Potential distribution terminal
Housing Type HD (High Density) housing
Housing Width 12 mm
Housing Material Polycarbonate

Electrical

Parameter Specification
Nominal Voltage Max. 60 V DC
Current Load per Power Contact Max. 10 A
E-Bus Current Consumption 0 mA (passive)
Electrical Isolation 500 V (E-bus / field potential)
Bit Width in Process Image 0

Connection and Wiring

Parameter Specification
Connection Technology Direct plug-in (push-in technique)
Number of Connection Points 16 (8 x 24 V, 8 x 0 V)
Solid Wire Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Stranded Wire Cross-Section 0.25 to 1.5 mm² (AWG 22 to 16)
Ferrule Cross-Section 0.14 to 0.75 mm² (AWG 26 to 19)
Stripping Length 8 to 9 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 60 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Installation 35 mm DIN rail (conforming to EN 60715)
Side-by-Side Mounting Connection Double slot and key connection

Connections / Interfaces

Terminal Points Function
1 to 8 24 V DC distribution points (internal power contact connection)
9 to 16 0 V DC distribution points (internal power contact connection)

Installation Guidelines

  1. Ensure the entire control system and the specific terminal segment are fully de-energized before beginning installation or maintenance.
  2. Mount the BECKHOFF EL9184 onto a standard 35 mm DIN rail by snapping it into place until the locking mechanism engages.
  3. Ensure correct side-by-side positioning with adjacent EtherCAT Terminals to allow the internal power contacts to align and interface properly.
  4. For solid conductors, insert the wire directly into the connection point. For stranded or ferruled conductors, actuate the spring mechanism using a suitable screwdriver before inserting the wire.
  5. Check that the total current load across the distributed power contacts does not exceed the maximum rated limit of 10 A.

Compliance and Certifications

Certification Type Details
CE Compliant
UL cULus approved
ATEX Ex Marking II 3 G Ex nA IIC T4 Gc
Loading product navigation…

What is the primary function of the BECKHOFF EL9184?

The BECKHOFF EL9184 is a potential distribution terminal designed to distribute 24 V DC and 0 V DC potentials directly from adjacent power contacts to 16 individual connection points, saving wiring and DIN rail space.

Does the BECKHOFF EL9184 consume E-bus current?

No, the BECKHOFF EL9184 is a passive module and has an E-bus current consumption of 0 mA, meaning it does not load the E-bus power supply.

What types of wires can be used with the BECKHOFF EL9184?

The BECKHOFF EL9184 accepts solid wires from 0.08 to 1.5 mm² (AWG 28–16) using toolless direct plug-in insertion, as well as stranded wires (0.25 to 1.5 mm²) and wires with ferrules (0.14 to 0.75 mm²) via spring-actuation.

What is the maximum current rating for the BECKHOFF EL9184?

The BECKHOFF EL9184 supports a maximum current load of 10 A across its power contacts, with a nominal operating voltage rating of up to 60 V DC.

Does the BECKHOFF EL9184 require software configuration in TwinCAT?

No, the BECKHOFF EL9184 has a 0-bit process image width and acts purely as a passive physical routing system, so it does not require software configuration or mapping in TwinCAT.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...