BECKHOFF

BECKHOFF ELM9410 Power Supply Terminal

SKU ELM9410

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: ELM9410
  • Origin Germany
  • Product Type: Power Supply Terminals
  • Payment: T/T, Western Union
  • Weight: 0.45 kg
  • Dimensions: 30 mm x 100 mm x 95 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF ELM9410 is a high-performance power supply terminal designed to refresh the E-bus (EtherCAT bus) current in demanding industrial applications. Housed in a robust zinc die-cast metal enclosure, this terminal supplies up to 2 A of E-bus current (5 V DC), allowing for the extension and reliable operation of large-scale EtherCAT terminal segments. It is specifically optimized to maintain signal integrity and power stability in environments that utilize ELM-series measurement modules.

To ensure high operational reliability, the BECKHOFF ELM9410 features electrical isolation of up to 500 V between the E-bus, US, and UP potentials. The terminal also integrates reverse polarity protection on inputs alongside active diagnostics. Operating and supply voltage levels are monitored continuously, with diagnostic data directly written into the PLC process image for real-time status evaluation and preventive maintenance.

Features

  • Replenishes the E-bus current with an output capacity of up to 2 A (5 V DC).
  • Integrated diagnostic monitoring of supply and output voltages reported directly in the process image.
  • Robust zinc die-cast metal housing providing high mechanical stability and signal shielding.
  • Electrical isolation of 500 V between the E-bus and field potentials.
  • Reverse polarity protection to prevent damage from incorrect field wiring.
  • Direct plug-in push-in wiring for solid conductors, with easy spring actuation for stranded wires.

Applications

  • Refreshing the E-bus current in complex, multi-terminal EtherCAT systems.
  • Segmenting potential groups in high-accuracy ELM measurement terminal installations.
  • Industrial test stands and automation systems requiring robust shielded enclosures and detailed power diagnostics.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model ELM9410
Product Type Power supply terminal for refreshing the E-bus
Housing Material Zinc die-cast with integrated signal LEDs
Design Form Metal housing
Protection Rating IP20
Installation Position Variable

Electrical Data

Parameter Specification
Input Voltage 24 V DC (-15 % / +20 %)
Output Voltage 5 V DC (for E-bus supply)
E-Bus Current Supply 2000 mA (2 A)
Current Consumption from US 50 mA + (total E-bus current / 4)
Current Consumption from UP 50 mA + load
Power Contacts Max. 24 V DC / Max. 2 A
Electrical Isolation 500 V (E-bus / field potential / US / UP)
Short-Circuit Proof Yes
Diagnostics Yes (supply and output voltage monitoring in process image)

Connection and Wiring

Parameter Specification
Wiring Technology Solid conductors: direct plug-in; Fine-stranded: spring actuation by screwdriver
Conductor Cross-Section (Solid) 0.2 to 1.5 mm² (AWG 24 to 14)
Conductor Cross-Section (Stranded) 0.2 to 1.5 mm² (AWG 24 to 14)
Conductor Cross-Section (Ferrule) 0.25 to 0.75 mm² (AWG 24 to 14)
Stripping Length 8 to 9 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 30 mm x 100 mm x 95 mm
Weight Approx. 450 g
Mounting 35 mm DIN rail (conforming to EN 60715) with lock
Side-by-Side Mounting Double slot and key connection
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Relative Humidity 95 %, non-condensing
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. System De-energization: Completely isolate and turn off all power sources supplying the terminal segment and the E-bus prior to installation or maintenance.
  2. DIN Rail Mounting: Snap the terminal securely onto a standard 35 mm DIN rail (EN 60715). Use the integrated locking latch to fix it in place.
  3. Side-by-Side Connection: Ensure proper engagement of the double slot and key connections when mounting adjacent ELM-series modules.
  4. Wiring: Insert solid conductors directly into the plug-in terminal connection. For fine-stranded wires or ferrules, depress the orange spring actuator using a standard flat-head screwdriver before inserting the wire. Strip wires strictly to 8–9 mm.
  5. Grounding and Shielding: Confirm that the DIN rail is properly grounded to ensure effective EMC shielding through the zinc die-cast housing.
  6. Commissioning: Power on the system and verify the statuses of the diagnostic signal LEDs. Verify that the correct voltage diagnostics are visible within the TwinCAT system manager or process image.

Compliance and Certifications

  • CE
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF ELM9410 terminal?
The BECKHOFF ELM9410 is a power supply terminal designed to refresh the E-bus (EtherCAT bus) current in system segments, providing up to 2 A of 5 V DC output current to downstream terminals.
Does the BECKHOFF ELM9410 provide system diagnostics?
Yes, the BECKHOFF ELM9410 offers integrated diagnostics of both input supply and output voltages, which are written directly into the process image for real-time PLC monitoring.
What type of housing does the BECKHOFF ELM9410 use?
The BECKHOFF ELM9410 features a high-grade zinc die-cast metal housing designed for maximum physical protection and signal shielding, weighing approximately 450 g.
What are the electrical isolation ratings for the BECKHOFF ELM9410?
The BECKHOFF ELM9410 provides an insulation voltage rating of 500 V between the E-bus, US, and UP field potentials to secure communication and power integrity.
How is wiring secured on the BECKHOFF ELM9410?
The BECKHOFF ELM9410 uses direct push-in technology for solid conductors, and standard spring-actuator connection points for fine-stranded or ferruled wires (compatible with AWG 24 to 14 sizes).
Reviews

ELM9410

Stock & lead time on request

Call
1 of 1

BECKHOFF ELM9410 Power Supply Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ELM9410

  • Country of origin:Germany

  • Product Type: Power Supply Terminals

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 30 mm x 100 mm x 95 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF ELM9410 is a high-performance power supply terminal designed to refresh the E-bus (EtherCAT bus) current in demanding industrial applications. Housed in a robust zinc die-cast metal enclosure, this terminal supplies up to 2 A of E-bus current (5 V DC), allowing for the extension and reliable operation of large-scale EtherCAT terminal segments. It is specifically optimized to maintain signal integrity and power stability in environments that utilize ELM-series measurement modules.

To ensure high operational reliability, the BECKHOFF ELM9410 features electrical isolation of up to 500 V between the E-bus, US, and UP potentials. The terminal also integrates reverse polarity protection on inputs alongside active diagnostics. Operating and supply voltage levels are monitored continuously, with diagnostic data directly written into the PLC process image for real-time status evaluation and preventive maintenance.

Features

  • Replenishes the E-bus current with an output capacity of up to 2 A (5 V DC).
  • Integrated diagnostic monitoring of supply and output voltages reported directly in the process image.
  • Robust zinc die-cast metal housing providing high mechanical stability and signal shielding.
  • Electrical isolation of 500 V between the E-bus and field potentials.
  • Reverse polarity protection to prevent damage from incorrect field wiring.
  • Direct plug-in push-in wiring for solid conductors, with easy spring actuation for stranded wires.

Applications

  • Refreshing the E-bus current in complex, multi-terminal EtherCAT systems.
  • Segmenting potential groups in high-accuracy ELM measurement terminal installations.
  • Industrial test stands and automation systems requiring robust shielded enclosures and detailed power diagnostics.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model ELM9410
Product Type Power supply terminal for refreshing the E-bus
Housing Material Zinc die-cast with integrated signal LEDs
Design Form Metal housing
Protection Rating IP20
Installation Position Variable

Electrical Data

Parameter Specification
Input Voltage 24 V DC (-15 % / +20 %)
Output Voltage 5 V DC (for E-bus supply)
E-Bus Current Supply 2000 mA (2 A)
Current Consumption from US 50 mA + (total E-bus current / 4)
Current Consumption from UP 50 mA + load
Power Contacts Max. 24 V DC / Max. 2 A
Electrical Isolation 500 V (E-bus / field potential / US / UP)
Short-Circuit Proof Yes
Diagnostics Yes (supply and output voltage monitoring in process image)

Connection and Wiring

Parameter Specification
Wiring Technology Solid conductors: direct plug-in; Fine-stranded: spring actuation by screwdriver
Conductor Cross-Section (Solid) 0.2 to 1.5 mm² (AWG 24 to 14)
Conductor Cross-Section (Stranded) 0.2 to 1.5 mm² (AWG 24 to 14)
Conductor Cross-Section (Ferrule) 0.25 to 0.75 mm² (AWG 24 to 14)
Stripping Length 8 to 9 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 30 mm x 100 mm x 95 mm
Weight Approx. 450 g
Mounting 35 mm DIN rail (conforming to EN 60715) with lock
Side-by-Side Mounting Double slot and key connection
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Relative Humidity 95 %, non-condensing
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. System De-energization: Completely isolate and turn off all power sources supplying the terminal segment and the E-bus prior to installation or maintenance.
  2. DIN Rail Mounting: Snap the terminal securely onto a standard 35 mm DIN rail (EN 60715). Use the integrated locking latch to fix it in place.
  3. Side-by-Side Connection: Ensure proper engagement of the double slot and key connections when mounting adjacent ELM-series modules.
  4. Wiring: Insert solid conductors directly into the plug-in terminal connection. For fine-stranded wires or ferrules, depress the orange spring actuator using a standard flat-head screwdriver before inserting the wire. Strip wires strictly to 8–9 mm.
  5. Grounding and Shielding: Confirm that the DIN rail is properly grounded to ensure effective EMC shielding through the zinc die-cast housing.
  6. Commissioning: Power on the system and verify the statuses of the diagnostic signal LEDs. Verify that the correct voltage diagnostics are visible within the TwinCAT system manager or process image.

Compliance and Certifications

  • CE
Loading product navigation…

What is the primary function of the BECKHOFF ELM9410 terminal?

The BECKHOFF ELM9410 is a power supply terminal designed to refresh the E-bus (EtherCAT bus) current in system segments, providing up to 2 A of 5 V DC output current to downstream terminals.

Does the BECKHOFF ELM9410 provide system diagnostics?

Yes, the BECKHOFF ELM9410 offers integrated diagnostics of both input supply and output voltages, which are written directly into the process image for real-time PLC monitoring.

What type of housing does the BECKHOFF ELM9410 use?

The BECKHOFF ELM9410 features a high-grade zinc die-cast metal housing designed for maximum physical protection and signal shielding, weighing approximately 450 g.

What are the electrical isolation ratings for the BECKHOFF ELM9410?

The BECKHOFF ELM9410 provides an insulation voltage rating of 500 V between the E-bus, US, and UP field potentials to secure communication and power integrity.

How is wiring secured on the BECKHOFF ELM9410?

The BECKHOFF ELM9410 uses direct push-in technology for solid conductors, and standard spring-actuator connection points for fine-stranded or ferruled wires (compatible with AWG 24 to 14 sizes).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...