  • Manufacturer: BECKHOFF

  • Product No.: EP8309-1022

  • Country of origin:Germany

  • Product Type: EtherCAT Box Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 60 mm x 126 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Engineered for decentralized industrial environments requiring diverse signal integration, the Beckhoff EP8309-1022 provides high-density digital, analog, and PWM interfacing directly on the machine layer. This multi-functional EtherCAT Box consolidates multiple I/O types into a single, compact field module, eliminating the need for local control cabinets. Equipped with an integrated EtherCAT interface, it manages bidirectional communication, high-speed digital I/O, precise analog processing, and pulse-width modulation output within severe operating environments. The unit features standard M8 and M12 industrial connections, providing ruggedized IP67 protection and high immunity to electrical noise.

Features

  • Multi-functional I/O Configuration: Integrates digital inputs/outputs, analog inputs, an analog output, and a dedicated PWMi channel in one device.
  • Direct Field Integration: IP65/66/67 rating enables cabinet-free mounting directly on machines, reducing field wiring runs.
  • Configurable Digital Channels: 8 digital ports can be independently parameterized as inputs or outputs.
  • Flexible Analog Interface: Dual 12-bit analog inputs and a single 12-bit analog output supporting standard 0/4 to 20 mA current loops.
  • High-Speed PWMi Output: Single channel supporting up to 1.2 A at frequencies up to 30 kHz for proportional valve control.
  • Robust Electrical Isolation: 500 V isolation barrier protects internal control electronics from external field transients.

Applications

  • Decentralized machinery and tool manufacturing lines.
  • Proportional valve actuation and hydraulic manifold control.
  • Remote sensor and instrument concentration in wet or dusty processing plants.
  • Robotic end-of-arm tooling and dynamic assembly cells.

Technical Specifications

Specification Parameter Value / Definition
Manufacturer Beckhoff
Model Number EP8309-1022
Protocol / Bus System EtherCAT
Bus Connection Interface 2 x M8 socket, shielded, screw type
Digital Channels 8 digital inputs or outputs (channels 6 to 13)
Input Filter Time 3 ms
Limit Frequency 2.5 kHz
Analog Inputs 2 x single-ended, 12-bit, 0/4 to 20 mA (channels 0 and 2)
Analog Outputs 1 x single-ended, 12-bit, 0/4 to 20 mA (channel 15)
PWMi Outputs 1 x 1.2 A, max. 30 kHz (channel 14)
Nominal Operating Voltage 24 V DC (-15% / +20%)
Measurement Uncertainty Input: < 0.3%, Output: < 0.1% (relative to full scale)
Sensor / Actuator Supply Sensor from US (control voltage), Actuator from UP (auxiliary voltage)
Electrical Isolation 500 V
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Housing Material PA6 Polyamide
Module Dimensions 60 mm x 126 mm x 26.5 mm
Device Weight approx. 250 g
Shipping Weight 2.0 kg (packaged)

Empirical Engineering Insights

Alternative Models & Compatibility

The EP8309-1022 replaces separate, single-purpose IP67 boxes by packing analog, digital, and PWM functionalities into one footprint. It requires a modern TwinCAT configuration profile. Ensure that your TwinCAT 2 (or TwinCAT 3) EtherCAT XML Device Description (ESI) is updated to recognize this multi-functional unit, especially if transitioning from discrete EP1xxx or EP2xxx modules.

Application Pitfalls & Engineering Notes

When executing multi-channel deployment, pay careful attention to the combined current draw on the US (sensor supply) and UP (actuator supply) rails. The internal distribution tracks can overheat or trigger overcurrent faults if the total connected sensor/actuator load exceeds the design limits of the incoming M8 power cables. Additionally, verify signal routing on the PWMi output channel; high-frequency modulation (up to 30 kHz) on unshielded lines can induce noise on adjacent 12-bit analog input channels (0 and 2).

Commissioning & Wiring Tips

For stable current loop operation, ground loop offsets must be mitigated. Since the analog inputs are single-ended, ensure your transmitter sensors share a common potential base with the EP8309-1022's signal ground. For the EtherCAT network connection, use only fully shielded M8 connectors to ensure communication integrity in high-vibration and EMC-heavy environments conforming to EN 61000-6-2 guidelines.

Installation Guidelines

CRITICAL WARNING

Risk of electrical shock and equipment destruction. Isolate and lock out all 24 V DC power sources (both control voltage US and auxiliary voltage UP) before initiating physical installation, cable mating, or terminal modifications. Failure to de-energize may result in severe electronic component damage or operational communication failures on the EtherCAT ring.

1
Mechanical Mounting: Secure the polyamide enclosure to a flat surface using two 3.5 mm holes for M3 screws or two 4.5 mm holes for M4 screws. Ensure the torque does not crack the housing.
2
EtherCAT Port Cabling: Connect incoming and outgoing EtherCAT cables to the M8 sockets. Use shielded connectors and tighten to the recommended torque spec to maintain the IP67 environmental seal.
3
Field Signal Wiring: Connect the digital and analog field devices using standard M12 screw connections. Verify the pin mapping for current loop inputs on channels 0 and 2.
4
Power Supply Initialization: Connect the 24 V DC supply cables. Verify that LEDs light up and indicate solid link status before executing the online physical node discovery in your control software.
Loading product navigation…

Can I configure the 8 digital channels on the EP8309-1022 dynamically?

Yes. The 8 digital channels (channels 6 through 13) are configurable and can be individually set up as digital inputs or digital outputs via your TwinCAT software configuration.

What standard sensor current ranges are supported by the analog inputs?

The two single-ended, 12-bit analog inputs (channels 0 and 2) support industry-standard current-loop signal ranges of 0 to 20 mA or 4 to 20 mA.

How does the PWMi output channel operate?

The dedicated pulse-width modulation (PWMi) output on channel 14 can deliver a maximum current of 1.2 A at frequencies reaching up to 30 kHz, ideal for proportional valve control.

Does the EP8309-1022 require a local protective enclosure?

No. The unit features an IP65/66/67 physical protection rating, allowing it to be directly mounted onto machine frameworks in harsh, wet, or dusty industrial fields.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...