BECKHOFF

BECKHOFF EP1809-0021 EtherCAT Box 16-Channel Digital Input

SKU EP1809-0021

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EP1809-0021
  • Origin Germany
  • Product Type: EtherCAT Modules
  • Payment: T/T, Western Union
  • Weight: 0.25 kg
  • Dimensions: 12.6 x 3 x 2.6 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF EP1809-0021 EtherCAT Box is a digital input module featuring 16 channels designed for industrial automation environments requiring distributed signal acquisition. Operating directly within an EtherCAT network, this device connects binary control signals from sensors and switches to the automation controller, supporting reliable data communication across harsh plant floors.

Constructed in a rugged industrial housing with an IP65, IP66, and IP67 protection rating, the EP1809-0021 is engineered for direct machine mounting without requiring a control cabinet. It integrates M8 connectors for both signal inputs and network connections, facilitating straightforward installation and maintenance in decentralized machine topologies.

Features

    16 digital input channels compliant with EN 61131-2, type 1/3 specifications. Direct machine-level installation enabled by an IP65/IP66/IP67 rated housing. EtherCAT communication interface utilizing dual shielded M8 sockets for ring or line topologies. Integrated sensor supply powered from the control voltage with a total capacity of up to 0.5 A and short-circuit protection. M8 connection technology featuring 3-pin A-coded sockets for signal wiring and 4-pin M8 connectors for power feed and downstream distribution.

Applications

    Decentralized machine control architectures without control cabinets Automated manufacturing lines requiring distributed sensor data acquisition Conveyor systems and material handling equipment with high IP rating requirements Packaging and assembly machinery operating in wet or dusty industrial environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EP1809-0021
Product Type EtherCAT Box
Protocol EtherCAT
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Weight approx. 250 g
Country of Origin Germany

Signal and I/O

Parameter Specification
Number of Inputs 16
Specification EN 61131-2, type 1/3
Nominal Input Voltage 24 V DC (-15 % / +20 %)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V
Input Current typ. 3 mA
Input Filter 3.0 ms
Counting Frequency max. 1 kHz
Sensor Supply from control voltage, max. 0.5 A, short-circuit proof in total

Electrical and Communication

Parameter Specification
Bus Interface 2 x M8 socket, shielded, screw type
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin
Current Consumption from US typ. 130 mA
Electrical Isolation 500 V

Environmental and Mechanical

Parameter Specification
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Vibration Resistance conforms to EN 60068-2-6
Shock Resistance conforms to EN 60068-2-27
EMC Immunity conforms to EN 61000-6-2
EMC Emission conforms to EN 61000-6-4

Connections / Interfaces

Interface Function
Bus Interface (2 x M8 socket) EtherCAT input and output connections, shielded
Power Supply Feed (1 x M8 male, 4-pin) Incoming 24 V DC control voltage supply
Power Supply Downstream (1 x M8 female, 4-pin) Further distribution of 24 V DC control voltage to subsequent modules
Input Connections (16 x M8, 3-pin, A-coded) Connection points for 16 digital sensors

Installation Guidelines

  1. Ensure the system is completely de-energized before mounting or wiring the BECKHOFF EP1809-0021 EtherCAT Box.
  2. Mount the module securely onto a flat machine surface using the appropriate mounting holes to withstand operational vibration and shock.
  3. Connect the EtherCAT network cables to the shielded M8 bus sockets, ensuring proper cable routing and strain relief.
  4. Attach the 24 V DC power supply feed to the 4-pin M8 male socket and verify correct voltage polarity.
  5. Connect field sensors to the 3-pin A-coded M8 input sockets, ensuring total current draw on the sensor supply does not exceed 0.5 A.
  6. Perform a complete wiring and continuity check before restoring power and commissioning the network via the automation software.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF EP1809-0021 EtherCAT Box?
The BECKHOFF EP1809-0021 EtherCAT Box serves as a decentralized 16-channel digital input module designed to acquire binary control signals directly on machines without requiring a control cabinet.
What environmental protection rating does the BECKHOFF EP1809-0021 provide?
The BECKHOFF EP1809-0021 features IP65, IP66, and IP67 protection ratings, making it dust-tight and protected against water jets and temporary immersion.
How are sensors connected to the BECKHOFF EP1809-0021?
Sensors connect to the BECKHOFF EP1809-0021 via 16 individual M8 x 1 connectors using 3-pin, A-coded connection technology.
What is the sensor supply capacity on the BECKHOFF EP1809-0021?
The BECKHOFF EP1809-0021 provides a total sensor supply derived from the control voltage of up to 0.5 A, which is short-circuit protected.
Reviews

EP1809-0021

Stock & lead time on request

Call
1 of 1

BECKHOFF EP1809-0021 EtherCAT Box 16-Channel Digital Input

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EP1809-0021

  • Country of origin:Germany

  • Product Type: EtherCAT Modules

  • Payment: T/T, Western Union

  • Weight: 250g

  • Dimensions: 12.6 x 3 x 2.6 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF EP1809-0021 EtherCAT Box is a digital input module featuring 16 channels designed for industrial automation environments requiring distributed signal acquisition. Operating directly within an EtherCAT network, this device connects binary control signals from sensors and switches to the automation controller, supporting reliable data communication across harsh plant floors.

Constructed in a rugged industrial housing with an IP65, IP66, and IP67 protection rating, the EP1809-0021 is engineered for direct machine mounting without requiring a control cabinet. It integrates M8 connectors for both signal inputs and network connections, facilitating straightforward installation and maintenance in decentralized machine topologies.

Features

    16 digital input channels compliant with EN 61131-2, type 1/3 specifications. Direct machine-level installation enabled by an IP65/IP66/IP67 rated housing. EtherCAT communication interface utilizing dual shielded M8 sockets for ring or line topologies. Integrated sensor supply powered from the control voltage with a total capacity of up to 0.5 A and short-circuit protection. M8 connection technology featuring 3-pin A-coded sockets for signal wiring and 4-pin M8 connectors for power feed and downstream distribution.

Applications

    Decentralized machine control architectures without control cabinets Automated manufacturing lines requiring distributed sensor data acquisition Conveyor systems and material handling equipment with high IP rating requirements Packaging and assembly machinery operating in wet or dusty industrial environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EP1809-0021
Product Type EtherCAT Box
Protocol EtherCAT
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Weight approx. 250 g
Country of Origin Germany

Signal and I/O

Parameter Specification
Number of Inputs 16
Specification EN 61131-2, type 1/3
Nominal Input Voltage 24 V DC (-15 % / +20 %)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V
Input Current typ. 3 mA
Input Filter 3.0 ms
Counting Frequency max. 1 kHz
Sensor Supply from control voltage, max. 0.5 A, short-circuit proof in total

Electrical and Communication

Parameter Specification
Bus Interface 2 x M8 socket, shielded, screw type
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin
Current Consumption from US typ. 130 mA
Electrical Isolation 500 V

Environmental and Mechanical

Parameter Specification
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Vibration Resistance conforms to EN 60068-2-6
Shock Resistance conforms to EN 60068-2-27
EMC Immunity conforms to EN 61000-6-2
EMC Emission conforms to EN 61000-6-4

Connections / Interfaces

Interface Function
Bus Interface (2 x M8 socket) EtherCAT input and output connections, shielded
Power Supply Feed (1 x M8 male, 4-pin) Incoming 24 V DC control voltage supply
Power Supply Downstream (1 x M8 female, 4-pin) Further distribution of 24 V DC control voltage to subsequent modules
Input Connections (16 x M8, 3-pin, A-coded) Connection points for 16 digital sensors

Installation Guidelines

  1. Ensure the system is completely de-energized before mounting or wiring the BECKHOFF EP1809-0021 EtherCAT Box.
  2. Mount the module securely onto a flat machine surface using the appropriate mounting holes to withstand operational vibration and shock.
  3. Connect the EtherCAT network cables to the shielded M8 bus sockets, ensuring proper cable routing and strain relief.
  4. Attach the 24 V DC power supply feed to the 4-pin M8 male socket and verify correct voltage polarity.
  5. Connect field sensors to the 3-pin A-coded M8 input sockets, ensuring total current draw on the sensor supply does not exceed 0.5 A.
  6. Perform a complete wiring and continuity check before restoring power and commissioning the network via the automation software.
Loading product navigation…

What is the primary function of the BECKHOFF EP1809-0021 EtherCAT Box?

The BECKHOFF EP1809-0021 EtherCAT Box serves as a decentralized 16-channel digital input module designed to acquire binary control signals directly on machines without requiring a control cabinet.

What environmental protection rating does the BECKHOFF EP1809-0021 provide?

The BECKHOFF EP1809-0021 features IP65, IP66, and IP67 protection ratings, making it dust-tight and protected against water jets and temporary immersion.

How are sensors connected to the BECKHOFF EP1809-0021?

Sensors connect to the BECKHOFF EP1809-0021 via 16 individual M8 x 1 connectors using 3-pin, A-coded connection technology.

What is the sensor supply capacity on the BECKHOFF EP1809-0021?

The BECKHOFF EP1809-0021 provides a total sensor supply derived from the control voltage of up to 0.5 A, which is short-circuit protected.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors in different ways. This comparison covers torque quality, speed range, reversal, braking, electrical noise, thermal behavior, feedback, and retrofit...

How Industrial Inverters Build AC From a DC Bus

Industrial inverters synthesize controllable AC from a DC bus through semiconductor switching and filtering. This guide explains H-bridges, PWM, harmonics, motor loads, protection, thermal limits,...

Robot Force Control: From Contact Detection to Stable Process

Force control lets a robot adapt to contact instead of following position alone. This guide compares sensing approaches, control modes, process limits, safety boundaries, commissioning tests, and...

When Sensor-Level Logic Helps—and When It Hides Risk

Configurable sensors can perform window, latch, delay, and Boolean decisions before data reaches a PLC. The benefit is faster local behavior; the risk is hidden logic, weak diagnostics, and...

Connecting GX Simulator to Factory I/O Through OPC

A stable Mitsubishi virtual commissioning setup requires more than matching addresses. This guide explains the GX Simulator–OPC–Factory I/O data path, namespace design, scan timing, validation, and...